991 resultados para solid dosage form
Resumo:
This paper describes preliminary work done towards the development of new metallic heterogeneous catalysts to be used in the transesterification reaction of triglycerides, which is of considerable interest in the production of biodiesel. Biodiesel, is a mixture of mono-alkyl esters of fatty acids, and is currently manufactured by transesterification of triglycerides with methanol using NaOH or KOH as liquid base catalyst. Catalysts as such are corrosive to the equipment, and as these catalysts are in liquid phase must be neutralized after the completion of the reaction, typically using HCl, thus producing salt streams. Moreover, due to the presence of free fatty acids it reacts to form soaps as unwanted by-products, hence requiring more expensive separation processes. Therefore, there is a great need on the development of industrial processes for biodiesel production using solid acid catalysts. The key benefit of using solid acid catalysts is that no polluting by-products are formed and the catalysts do not have to be removed since they do not mix with the biodiesel product.
Resumo:
A newly developed solid-state repetitive high-voltage (HV) pulse modulator topology created from the mature concept of the d.c. voltage multiplier (VM) is described. The proposed circuit is based in a voltage multiplier type circuit, where a number of d.c. capacitors share a common connection with different voltage rating in each one. Hence, besides the standard VM rectifier and coupling diodes, two solid-state on/off switches are used, in each stage, to switch from the typical charging VM mode to a pulse mode with the d.c. capacitors connected in series with the load. Due to the on/off semiconductor configuration, in half-bridge structures, the maximum voltage blocked by each one is the d.c. capacitor voltage in each stage. A 2 kV prototype is described and the results are compared with PSPICE simulations.
Resumo:
This paper addresses the voltage droop compensation associated with long pulses generated by solid-stated based high-voltage Marx topologies. In particular a novel design scheme for voltage droop compensation in solid-state based bipolar Marx generators, using low-cost circuitry design and control, is described. The compensation consists of adding one auxiliary PWM stage to the existing Marx stages, without changing the modularity and topology of the circuit, which controls the output voltage and a LC filter that smoothes the voltage droop in both the positive and negative output pulses. Simulation results are presented for 5 stages Marx circuit using 1 kV per stage, with 1 kHz repetition rate and 10% duty cycle.
Resumo:
The purpose of this paper is to present and discuss a general HV topology of the solid-state Marx modulator, for unipolar or bipolar generation connected with a step-up transformer to increase the output voltage applied to a resistive load. Due to the use of an output transformer, discussion about the reset of the transformer is made to guarantee zero average voltage applied to the primary. It is also discussed the transformer magnetizing energy recovering back to the energy storage capacitors. Simulation results for a circuit that generates 100 kV pulses using 1000 V semiconductors are presented and discussed regarding the voltage and current stress on the semiconductors and result obtained.
Resumo:
Sub-nanosecond bipolar high voltage pulses are a very important tool for food processing, medical treatment, waste water and exhaust gas processing. A Hybrid Modulator for sub-microsecond bipolar pulse generation, comprising an unipolar solid-state Marx generator connected to a load through a stack Blumlein system that produces bipolar pulses and further multiplies the pulse voltage amplitude, is presented. Experimental results from an assembled prototype show the generation of 1000 V amplitude bipolar pulses with 100 ns of pulse width and 1 kHz repetition rate.
Resumo:
This paper, reports experimental work on the use of new heterogeneous solid basic catalysts for biodiesel production: double oxides of Mg and Al, produced by calcination, at high temperature, of MgAl lamellar structures, the hydrotalcites (HT). The most suitable catalyst system studied are hydrotalcite Mg:Al 2:1 calcinated at 507 degrees C and 700 degrees C, leading to higher values of FAME also in the second reaction stage. One of the prepared catalysts resulted in 97.1% Fatty acids methyl esters (FAME) in the 1st reaction step, 92.2% FAME in the 2nd reaction step and 34% FAME in the 3rd reaction step. The biodiesel obtained in the transesterification reaction showed composition and quality parameters within the limits specified by the European Standard EN 14214. 2.5% wt catalyst/oil and a molar ratio methanol:oil of 9:1 or 12:1 at 60 -65 degrees C and 4 h of reaction time are the best operating conditions achieved in this study. This study showed the potential of Mg/Al hydrotalcites as heterogeneous catalysts for biodiesel production. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Trends between the Hammett's sigma(p) and related normal sigma(n)(p), inductive sigma(I), resonance sigma(R), negative sigma(-)(p) and positive sigma(+)(p) polar conjugation and Taft's sigma(o)(p) substituent constants and the N-H center dot center dot center dot O distance, delta(N-H) NMR chemical shift, oxidation potential (E-p/2(ox), measured in this study by cyclic voltammetry (CV)) and thermodynamic parameters (pK, Delta G(0), Delta H-0 and Delta S-0) of the dissociation process of unsubstituted 3-(phenylhydrazo)pentane-2,4-dione (HL1) and its para-substituted chloro (HL2), carboxy (HL3), fluoro (HL4) and nitro (HL5) derivatives were recognized. The best fits were found for sigma(p) and/or sigma(-)(p) in the cases of d(N center dot center dot center dot O), delta(N-H) and E-p/2(ox), showing the importance of resonance and conjugation effects in such properties, whereas for the above thermodynamic properties the inductive effects (sigma(I)) are dominant. HL2 exists in the hydrazo form in DMSO solution and in the solid state and contains an intramolecular H-bond with the N center dot center dot center dot O distance of 2.588(3)angstrom. It was also established that the dissociation process of HL1-5 is non-spontaneous, endothermic and entropically unfavourable, and that the increase in the inductive effect (sigma(I)) of para-substitutents (-H < -Cl < -COOH < -F < -NO2) leads to the corresponding growth of the N center dot center dot center dot O distance and decrease of the pK and of the changes of Gibbs free energy, of enthalpy and of entropy for the HL1-5 acid dissociation process. The electrochemical behaviour of HL1-5 was interpreted using theoretical calculations at the DFT/HF hybrid level, namely in terms of HOMO and LUMO compositions, and of reactivities induced by anodic and cathodic electron-transfers. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
OBJETIVO: Traduzir e validar para a língua portuguesa o questionário de qualidade de vida condição-específico denominado International Consultation on Incontinence Questionnaire - Short Form (ICIQ-SF) em pacientes com incontinência urinária. MÉTODOS: Duas traduções independentes do ICIQ-SF foram feitas por brasileiros, fluentes na língua inglesa. Após harmonização das mesmas, a tradução resultante foi retrotraduzida independentemente por dois nativos de países de língua inglesa. As diferenças foram harmonizadas e pré-testadas em um estudo piloto. A versão final do ICIQ-SF para o português, bem como a versão em português do King's Health Questionnaire (KHQ) foram aplicadas simultaneamente em 123 pacientes consecutivos com queixa de incontinência urinária (29 homens e 94 mulheres) que procuraram o laboratório de uroginecologia e o serviço de urodinâmica de um hospital universitário, localizado em Campinas. Foram testadas as propriedades psicométricas do questionário, como confiabilidade e validade de constructo. RESULTADOS: A idade mediana foi de 53 anos (intervalo de 16 a 86 anos). O período médio de reteste para o ICIQ-SF foi de 14,37 dias (intervalo de seis a 41 dias). Nenhuma alteração do formato original do ICIQ-SF foi observada no final do processo de tradução e adaptação cultural. A consistência interna foi alta, como demonstrado pelo coeficiente alfa de Cronbach (0,88). O resultado do teste-reteste foi considerado de moderado a forte, como indicado pelo índice Kappa ponderado, cujos valores variaram de 0,72 a 0,75, e o coeficiente de correlação de Pearson que foi de 0,89. A correlação entre o ICIQ-SF e o KHQ foi considerada de moderada a boa para a maioria dos itens, variando de 0,44 a 0,77. A avaliação das validades de constructo e concorrente foi também satisfatória e estatisticamente significante. CONCLUSÕES: A versão para o português do ICIQ-SF foi traduzida e validada com sucesso para aplicação em pacientes brasileiros de ambos os sexos, com queixa de incontinência urinária, apresentando satisfatória confiabilidade e validade de constructo.
Resumo:
A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
Dissertação de Mestrado em Engenharia e Gestão de Sistemas de Água.
Resumo:
A procura de piscinas para a prática de atividades desportivas, recreativas e/ou terapêuticas tem sofrido um aumento gradual ao longo do tempo. No entanto, nas piscinas existem vários perigos associados à sua utilização. Relativamente aos perigos químicos, a utilização de desinfetantes à base de cloro, bromo ou compostos derivados vai, por um lado, inativar microrganismos patogénicos mas, por outro, dar origem a subprodutos ao reagir com compostos orgânicos presentes na água. Os trihalometanos são um exemplo de subprodutos que se podem formar e, entre os compostos principais, estão o clorofórmio (TCM), bromodiclorometano (BDCM), clorodibromometano (CDBM) e bromofórmio (TBM). Este trabalho teve como objetivo o desenvolvimento de uma metodologia analítica para a determinação de trihalometanos em água e ar de piscinas e a sua aplicação a um conjunto de amostras. Para a análise dos compostos, foi utilizada a microextração em fase sólida no espaço de cabeça (HS-SPME) com posterior quantificação dos compostos por cromatografia gasosa com detetor de captura eletrónica (GC-ECD). Foi realizada uma otimização das condições de extração dos compostos em estudo em amostras de água, através da realização de dois planeamentos experimentais. As condições ótimas são assim obtidas para uma temperatura de extração de 45ºC, um tempo de extração de 25 min e um tempo de dessorção de 5 min. Foram analisadas amostras de águas de piscina cedidas pelo Centro de Estudos de Águas, sendo avaliada a aplicação da técnica HS-SPME e o efeito de matriz. O modo como se manuseiam as soluções que contêm os compostos em estudo influencia os resultados devido ao facto destes serem bastante voláteis. Concluiu-se também que existe efeito de matriz, logo a concentração das amostras deverá ser determinada através do método de adição de padrão. A caraterização da água de piscinas interiores permitiu conhecer a concentração de trihalometanos (THMs). Foram obtidas concentrações de TCM entre 4,5 e 406,5 μg/L sendo que apenas 4 das 27 amostras analisadas ultrapassam o valor limite imposto pelo Decreto-Lei nº306/2007 (100 μg/L) no que diz respeito a águas de consumo humano e que é normalmente utilizado como valor indicativo para a qualidade das águas de piscina. Relativamente à concentração obtida no ar de uma piscina interior, foi detetada uma concentração média de 224 μg/m3 de TCM, valor muito abaixo dos 10000 μg/m3 impostos pelo Decreto-lei nº24/2012, como valor limite para exposição profissional a agentes químicos.
Resumo:
A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.
Resumo:
A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.