902 resultados para UV degradation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper evaluates the adsorption capacity of zirconocene-based silica materials in the pre-concentration of antimicrobians (tetracycline, sulfamethoxazole and trimethoprim) in aqueous medium. These materials were prepared by grafting the zirconocene onto silicas pre-treated at different temperatures. The retention capacity of these materials was evaluated by off line SPE and HPLC-UV and the proposed methodology was validated in ultrapure, tap and river water. The recovery for tetracycline was 72% (in the solid phase A) and, for sulfamethoxazole and trimethoprim was 68 and 95% in the commercial C18, respectively. The target antimicrobians were not detected in the Arroio Dilúvio (Porto Alegre - RS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemical stability of enalapril drug substance and tablets was studied by a stability-indicating liquid chromatographic method. Stress testing was performed on drug substance under various conditions. Accelerated stability testing was carried out for different formulations of enalapril tablets. Chromatographic separation was achieved on a RP-18 column, using a mobile phase of methanol phosphate buffer at 1.0 mL min"1 and UV detection. Degradation of the drug substance was greater under hydrolytic conditions. After 180 days of accelerated stability testing most enalapril tablets showed more than 10% of degradation. Enalapril drug substance and tablets showed instability under stress and accelerated testing respectively, with possible implications on the therapeutic activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The post-preparative size-selective precipitation technique was applied in CdTe and CdSe semiconductor nanocrystals prepared via colloidal route in water. The synthesis of CdTe and CdSe nanoparticles and the effect of the post-preparative size-selective precipitation have been characterized mainly by mean of ultraviolet and visible absorption spectroscopy (UV-Vis). It was demonstrated that the size-selective precipitation are able to isolate particles of different sizes and purify the nanoparticles as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the optimization and method validation for sulfonamides (sulfamethazine, sulfaquinoxaline, sulfadimethoxine and sulfathiazole) in shrimp muscle using HPLC-UV. The sulfonamides were extracted with acetonitrile and acetic acid, and the extract cleaned up with a Strata SCX SPE cartridge prior to analysis. The method presented linearity in the range of 20-120 µg kg-1, good linear correlation (r > 0.99), and limits of quantification in the range of 4.7-20.2 µg kg-1. The recovery for shrimp muscles spiked with 50-150 µg kg-1 ranged from 63.2-108.0%. Precision and accuracy analysis showed acceptable relative standard deviation. Commercial shrimps were analyzed and sulfonamides don't were found above of the method limit of quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on a modification of the procedures originally described in the French Pharmacopoeia for the UV-visible spectrometric analysis of flavonoids, and proposes a validation of the method and its application in the determination of total flavonoids from sugarcane (Saccharum officinarum) leaves and vinasse. An analysis of precision and accuracy revealed a low relative standard deviation (< 5.0%) and a good recovery percentages (99.79 and 98.34%). A comparison of the spectrometric results against those obtained by high performance liquid chromatography (HPLC-UV) demonstrated complete compatibility between the modified French Pharmacopoeia (spectrometric) and HPLC-UV methods

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the validation of UV spectrophotometric method for quantitative determination of gemifloxacin mesylate (GFM) in tablets using methanol as solvent. The method was specific, linear, precise, exact and robust at 272 and 343 nm. The results confirmed that the method in both wavelengths is valid and useful to the routine quality control of GFM in coated tablets. The validate method was compared to liquid chromatography (HPLC), microbiological assay and visible (VIS) spectrophotometry, which were previously developed and validated to the same drug. There was not significative difference between the methods for GFM quantitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positive photoresists are widely used in lithographic process in microelectronics and in optics for the fabrication of relief components. With the aim of identifying molecular modifications among positive photoresists unexposed and previously exposed to ultraviolet light the electron stimulated ion desorption technique coupled to time-of-flight mass spectrometry was employed in the study of the AZ-1518 photoresist. Mass spectra were obtained as a function of the electron beam energy, showing specific changes related to the photochemical decomposition of the photoresist. This reinforces the applicability of the technique to investigate and characterize structural changes in photosensitive materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work involved the study of degradation of the herbicide bentazone in aqueous solution by different routes, in order to search a method that generates safe products to the environment. It was tested electrochemical polarization methods involving positive and negative potential, irradiation with UV light and deposition of TiO2 on the electrode surface, seeking a catalytic effect. After different times of degradation, aliquots were removed and the scan of molecular absorption spectrum of UV-Vis was performed. From the spectra decay of bentazone, the kinetics of different processes was accompanied and the rate constants were determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vitamin C, an exogenous antioxidant, is essential to human health. In this study, a method was validated to serum vitamin C quantification by HPLC-UV. Its stability with and without the use of tris [2-carboxy-ethyl] phosphine hydrochloride (TCEP), at -20 and -80 °C, in serum and supernatant were also evaluated. Analysis showed r² > 0.99, precision CV% < 15% and % bias < 15%, being linear, precise and accurate. The stability test revealed that using TCEP in serum storage at -20 and -80 °C or in supernatant at -80 °C the vitamin C levels remain stable for 30 and 12 days, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The bioassay, first order derivative UV spectrophotometry and chromatographic methods for assaying fluconazole capsules were compared. They have shown great advantages over the earlier published methods. Using the first order derivative, the UV spectrophotometry method does not suffer interference of excipients. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. All methods were linear and reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diclofenac is one of most frequently detected compounds in the water cycle. In this work, the effect of initial concentration, liquid inclusion complexes with β-Cyclodextrins (β-CDs) on the photodegradation of diclofenac were studied. Six phototransformation products were detected by HPLC chromatograms. UV-absorption spectra of diclofenac and phototransformation products were determined. One of the phototransformation products was identified. The degradation followed pseudo-first-order kinetics. The experiment showed that irradiation of diclofenac in the presence of β-CDs increase photodegradation rate and determined the optimal molar ratio of diclofenac to β-CDs as 1:2. The reduced photohaemolytic activity of diclofenac in the presence of β-CDs may be attributed to the sequestering and stabilizing of the radical intermediates and /or photoproducts by complexation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reliable method using LC-UV to assay mometasone furoate (MF) in creams or nasal sprays using the same chromatographic conditions was set up. Methanol:water 80:20 (v/v) (1.0 mL min-1) was used as mobile phase. MF was detected at 248 nm and analyzed in a concentration range from 1.0 to 20.0 µg mL-1. The method provided acceptable theoretical plates, peak simmetry, peak tailing factor and peak resolution a short run (5 min). The method showed specificity, good linearity (r = 0.9999) and the quantification limit was 0.379 µg mL-1. Furthermore, the method was precise (RSD < 2.0%), accurate (recovery > 97%) and robust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Caesalpinia peltophoroides is a domesticated tree found in Brazil. It was necessary to develop an analytical method to determine the content of total polyphenols (TP) in this herbal drug. The pre-analytical method was standardized for analysis time, wavelength, and the best standard to use. The optimum conditions were: pyrogallol, 760 nm, and 30 min respectively. Under these conditions, validation by UV/Vis spectrophotometry proved to be reliable for TP of the crude extract and semipurified fractions from C. peltophoroides. Standardization is required for every herbal drug, and this method proved to be linear, precise, accurate, reproducible, robust, and easy to perform.