861 resultados para Modal Flexibility Matrix
Resumo:
Matrix metalloproteinases (MMPs) are major executors of extracellular matrix remodeling and, consequently, play key roles in the response of cells to their microenvironment. The experimentally accessible stem cell population and the robust regenerative capabilities of planarians offer an ideal model to study how modulation of the proteolytic system in the extracellular environment affects cell behavior in vivo. Genome-wide identification of Schmidtea mediterranea MMPs reveals that planarians possess four mmp-like genes. Two of them (mmp1 and mmp2) are strongly expressed in a subset of secretory cells and encode putative matrilysins. The other genes (mt-mmpA and mt-mmpB) are widely expressed in postmitotic cells and appear structurally related to membrane-type MMPs. These genes are conserved in the planarian Dugesia japonica. Here we explore the role of the planarian mmp genes by RNA interference (RNAi) during tissue homeostasis and regeneration. Our analyses identify essential functions for two of them. Following inhibition of mmp1 planarians display dramatic disruption of tissues architecture and significant decrease in cell death. These results suggest that mmp1 controls tissue turnover, modulating survival of postmitotic cells. Unexpectedly, the ability to regenerate is unaffected by mmp1(RNAi). Silencing of mt-mmpA alters tissue integrity and delays blastema growth, without affecting proliferation of stem cells. Our data support the possibility that the activity of this protease modulates cell migration and regulates anoikis, with a consequent pivotal role in tissue homeostasis and regeneration. Our data provide evidence of the involvement of specific MMPs in tissue homeostasis and regeneration and demonstrate that the behavior of planarian stem cells is critically dependent on the microenvironment surrounding these cells. Studying MMPs function in the planarian model provides evidence on how individual proteases work in vivo in adult tissues. These results have high potential to generate significant information for development of regenerative and anti cancer therapies.
Resumo:
Organizations gain resources, skills and technologies to find out the ultimate mix of capabilities to be a winner in the competitive market. These are all important factors that need to be taken into account in organizations operating in today's business environment. So far, there are no significant studies on the organizational capabilities in the field of PSM. The literature review shows that the PSM capabilities need to be studied more comprehensively. This study attempts to reveal and fill this gap by providing the PSM capability matrix that identifies the key PSM capabilities approached from two angles: there are three primary PSM capabilities and nine subcapabilities and, moreover, the individual and organizational PSM capabilities are identified and evaluated. The former refers to the PSM capability matrix of this study which is based on the strategic and operative PSM capabilities that complement the economic ones, while the latter relates to the evaluation of the PSM capabilities, such as the buyer profiles of individual PSM capabilities and the PSMcapability map of the organizational ones. This is a constructive case study. The aim is to define what the purchasing and supply management capabilities are and how they can be evaluated. This study presents a PSM capability matrix to identify and evaluate the capabilities to define capability gaps by comparing the ideal level of PSM capabilities to the realized ones. The research questions are investigated with two case organizations. This study argues that PSM capabilities can be classified into three primary categories with nine sub-categories and, thus, a PSM capability matrix with four evaluation categories can be formed. The buyer profiles are moreover identified to reveal the PSM capability gap. The resource-based view (RBV) and dynamic capabilities view (DCV) are used to define the individual and organizational capabilities. The PSM literature is also used to define the capabilities. The key findings of this study are i) the PSM capability matrix to identify the PSM capabilities, ii) the evaluation of the capabilities to define PSM capability gaps and iii) the presentation of the buyer profiles to identify the individual PSM capabilities and to define the organizational PSM capabilities. Dynamic capabilities are also related to the PSM capability gap. If a gap is identified, the organization can renew their PSM capabilities and, thus, create mutual learning and increase their organizational capabilities. And only then, there is potential for dynamic capabilities. Based on this, the purchasing strategy, purchasing policy and procedures should be identified and implemented dynamically.
Resumo:
The objective of the thesis was to explore the nature and characteristics of customer-related internal communication in a global industrial matrix organization during a specific customer relationship, and how it could be improved. The theoretical part of the study views the field of the concepts of intra-organizational information and knowledge sharing. The theoretical part also views the internal communications influences to customer relationships, its problematic, and the suggestions to improve internal communication in literature. The empirical part of the study was conducted with the Content Analysis and the Social Network Analysis as research methods. The data was collected by interviews and a questionnaire. Internal communication was observed first generally within the organization from the point of view of a certain business, and secondly, during a specific customer relationship at personal level and at departmental level. The results of the study describe the nature and characteristics of internal communication in the organization. The results give 13 suggestions for improving internal communication in the organization. Although the study has been done in one specific organization, it also offers insights for other organizations as well as managers to improve their internal communication.
Resumo:
High-frequency oscillations in the gamma-band reflect rhythmic synchronization of spike timing in active neural networks. The modulation of gamma oscillations is a widely established mechanism in a variety of neurobiological processes, yet its neurochemical basis is not fully understood. Modeling, in-vitro and in-vivo animal studies suggest that gamma oscillation properties depend on GABAergic inhibition. In humans, search for evidence linking total GABA concentration to gamma oscillations has led to promising -but also to partly diverging- observations. Here, we provide the first evidence of a direct relationship between the density of GABAA receptors and gamma oscillatory gamma responses in human primary visual cortex (V1). By combining Flumazenil-PET (to measure resting-levels of GABAA receptor density) and MEG (to measure visually-induced gamma oscillations), we found that GABAA receptor densities correlated positively with the frequency and negatively with amplitude of visually-induced gamma oscillations in V1. Our findings demonstrate that gamma-band response profiles of primary visual cortex across healthy individuals are shaped by GABAA-receptor-mediated inhibitory neurotransmission. These results bridge the gap with in-vitro and animal studies and may have future clinical implications given that altered GABAergic function, including dysregulation of GABAA receptors, has been related to psychiatric disorders including schizophrenia and depression.
Resumo:
Guex, KJ, Lugrin, V, Borloz, S, and Millet, GP. Influence on strength and flexibility of a swing phase-specific hamstring eccentric program in sprinters' general preparation. J Strength Cond Res 30(2): 525-532, 2016-Hamstring injuries are common in sprinters and mainly occur during the terminal swing phase. Eccentric training has been shown to reduce hamstring injury rate by improving several risk factors. The aim of this study was to test the hypothesis that an additional swing phase-specific hamstring eccentric training in well-trained sprinters performed at the commencement of the winter preparation is more efficient to improve strength, ratio, optimum angle, and flexibility than a similar program without hamstring eccentric exercises. Twenty sprinters were randomly allocated to an eccentric (n = 10) or a control group (n = 10). Both groups performed their usual track and field training throughout the study period. Sprinters in the eccentric group performed an additional 6-week hamstring eccentric program, which was specific to the swing phase of the running cycle (eccentric high-load open-chain kinetic movements covering the whole hamstring length-tension relationship preformed at slow to moderate velocity). Isokinetic and flexibility measurements were performed before and after the intervention. The eccentric group increased hamstring peak torques in concentric at 60 degrees .s by 16% (p < 0.001) and at 240 degrees .s by 10% (p < 0.01), in eccentric at 30 degrees .s by 20% (p < 0.001) and at 120 degrees .s by 22% (p < 0.001), conventional and functional ratios by 12% (p < 0.001), and flexibility by 4 degrees (p < 0.01), whereas the control group increased hamstring peak torques only in eccentric at 30 degrees .s by 6% (p </= 0.05) and at 120 degrees .s by 6% (p < 0.01). It was concluded that an additional swing phase-specific hamstring eccentric training in sprinters seems to be crucial to address different risk factors for hamstring strain injuries, such as eccentric and concentric strength, hamstring-to-quadriceps ratio ratio, and flexibility.
Inactive matrix gla-protein is associated with arterial atiffness in an adult population-based study
Resumo:
La vitesse de l'onde de pouls (VOP) est la méthode pour mesurer la rigidité artérielle la plus répandue et la plus validée. C'est aussi un prédicteur indépendant de la mortalité. La Matrix Gla- protein (MGP) est une protein qui inhibe les calcifications vasculaires. MGP nécessite une enzyme dérivée de la vitamine K pour être activée, à l'instar de certains facteurs de coagulation. La forme inactive de MGP, connue sous le terme de « desphospho-uncarboxylated MGP » (dp-ucMGP), peut-être mesurée dans le plasma. Plus les apports de vitamine K sont importants plus les taux de dp-ucMGP diminue. Les taux de dp-ucMGP ont déjà été étudiés et associés à différents marqueurs cardiovasculaires (CV), aux événements CV et à la mortalité. Dans notre travail de recherche nous avons émis l'hypothèse que des taux élevés de dp-ucMGP seraient associés à une VOP élevée. Nous avons recruté les participants à travers une étude multicentrique suisse (SKIPOGH). Le processus de recrutement ciblait des familles dans lesquelles plusieurs membres étaient d'accord de participer. Nous avons mesuré la dp-ucMGP plasmatique grâce à la méthode immuno-enzymatique « ELISA ». Concernant la VOP, nous avons mesuré les ondes de pression au niveau carotidien et fémorale grâce à un tonomètre et calculer la vitesse de leurs propagations. Par la suite nous avons utilisé un modèle de régression linéaire multiple afin de déterminer le lien entre la VOP et dp- ucMGP. Le modèle était ajusté pour l'âge, la fonction rénale et les risques CV classiques. Nous avons inclut 1001 participants dans les analyses (475 hommes et 526 femmes). La valeur moyenne de la VOP était de 7.87 ± 2.10 (m/s) et celle de dp-ucMGP de 0.43 ± 0.20 (nmol/L). La VOP était positivement et significativement associée à dp-ucMGP avant comme après ajustement pour le sexe, l'âge, l'indice de masse corporel, la taille, la pression artérielle systolique et diastolique, la fréquence cardiaque, la fonction rénale, les taux de cholestérol (LDL, HDL), la glycémie, la consommation de tabac, la présence d'un diabète, l'utilisation de médicaments antihypertenseurs ou hypolipémiants et la présence d'antécédents CV (P<0.01). En conclusion, des taux élevés de dp-ucMGP sont positivement et indépendamment associés à la rigidité artérielle après ajustement pour les facteurs de risques CV traditionnels, la fonction rénale et l'âge. Des études expérimentales sont nécessaires afin de déterminer si une supplémentation en vitamine K permet de ralentir l'avancement de la rigidité artérielle grâce à son activation de la MGP.
Resumo:
Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode.
Resumo:
This review has tried to collect and correlate all the various equations for the g matrix of strong field d5 systems obtained from different basis sets using full electron and hole formalism calculations. It has corrected mistakes found in the literature and shown how the failure to properly take in symmetry boundary conditions has produced a variety of apparently inconsistent equations in the literature. The review has reexamined the problem of spin-orbit interaction with excited t4e states and finds that the earlier reports that it is zero in octahedral symmetry is not correct. It has shown how redefining what x, y, and z are in the principal coordinate system simplifies, compared to previous methods, the analysis of experimental g values with the equations.
Resumo:
Systems suppliers are focal actors in mechanical engineering supply chains, in between general contractors and component suppliers. This research concentrates on the systems suppliers’ competitive flexibility, as a competitive advantage that the systems supplier gains from independence from the competitive forces of the market. The aim is to study the roles that power, dependence relations, social capital, and interorganizational learning have on the competitive flexibility. Research on this particular theme is scarce thus far. The research method applied here is the inductive multiple case study. Interviews from four case companies were used as main source of the qualitative data. The literature review presents previous literature on subcontracting, supply chain flexibility, supply chain relationships, social capital and interorganizational learning. The result of this study are seven propositions and consequently a model on the effects that the dominance of sales of few customers, power of competitors, significance of the manufactured system in the end product, professionalism in procurement and the significance of brand products in the business have on the competitive flexibility. These relationships are moderated by either social capital or interorganizational learning. The main results obtained from this study revolve around social capital and interorganizational learning, which have beneficial effects on systems suppliers’ competitive flexibility, by moderating the effects of other constructs of the model. Further research on this topic should include quantitative research to provide the extent to which the results can be reliably generalized. Also each construct of the model gives possible focus for more thorough research.
Resumo:
A generalized off-shell unitarity relation for the two-body scattering T matrix in a many-body medium at finite temperature is derived, through a consistent real-time perturbation expansion by means of Feynman diagrams. We comment on perturbation schemes at finite temperature in connection with an erroneous formulation of the Dyson equation in a paper recently published.
Resumo:
The objective of this work was to manufacture biodegradable films based on cassava starch, polyvinyl alcohol (PVA) and sodium montmorillonite (Na-MMT), using glycerol as a plasticizer. These films were characterized according to their microstructure, optical, mechanical, and barrier properties. The combination of starch-PVA-MMT resulted in films with a more homogeneous surface than starch films. The introduction of PVA into the starch matrix led to the formation of films with lower water vapor permeability (WVP), higher tensile strength and greater elongation. MMT was exfoliated in the films, resulting in greater stability for different relative humidities, lower WVP, higher resistance and lower flexibility.
Resumo:
A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.