846 resultados para Improved invoicing
Resumo:
This study provides a versatile validated method to determine the total vitamin C content, as the sum of the contents of L-ascorbic acid (L-AA) and dehydroascorbic acid (DHAA), in several fruits and vegetables and its degradability with storage time. Seven horticultural crops from two different origins were analyzed using an ultrahigh-performance liquid chromatographic–photodiode array (UHPLC-PDA) system, equipped with a new trifunctional high strength silica (100% silica particle) analytical column (100 mm×2.1 mm, 1.7 μm particle size) using 0.1% (v/v) formic acid as mobile phase, in isocratic mode. This new stationary phase, specially designed for polar compounds, overcomes the problems normally encountered in HPLC and is suitable for the analysis of large batches of samples without L-AA degradation. In addition, it proves to be an excellent alternative to conventional C18 columns for the determination of L-AA in fruits and vegetables. The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, accuracy, and inter/intraday precision. Validation experiments revealed very good recovery rate of 96.6±4.4% for L-AA and 103.1±4.8 % for total vitamin C, good linearity with r2-values >0.999 within the established concentration range, excellent repeatability (0.5%), and reproducibility (1.6%) values. The LOD of the method was 22 ng/mL whereas the LOQ was 67 ng/mL. It was possible to demonstrate that L-AA and DHAA concentrations in the different horticulture products varied oppositely with time of storage not always affecting the total amount of vitamin C during shelf-life. Locally produced fruits have higher concentrations of vitamin C, compared with imported ones, but vegetables showed the opposite trend. Moreover, this UHPLC-PDA methodology proves to be an improved, simple, and fast approach for determining the total content of vitamin C in various food commodities, with high sensitivity, selectivity, and resolving power within 3 min of run analysis.
Resumo:
A presente pesquisa teve como objetivo estudar os efeitos fitotóxicos de fungicidas, acaricidas e inseticidas e algumas associações entre eles, em plantas de mamoeiros (Carica papaya L.) cv. Sunrise Solo Improved Line 72/12, em condições de campo, no município de São Mateus -- ES, pertencente à maior região produtora do Estado. O experimento foi arranjado em delineamento de blocos casualizados, com 4 repetições e 03 plantas úteis por parcela. Foram utilizados os seguintes produtos, com as respectivas doses, para cada 100 L de água: chlorothalonil (Daconil PM-200g); mancozeb (Dithane PM -- 200g); oxicloreto de cobre (Reconil -- 400g); thiabendazole (Tecto 450 -- 100ml); dicofol + tetradifon (Carbax -- 200ml); triazophós (Hostathion 400 BR -- 150ml); óxido de fenbutatina (Torque 500 SC -- 60ml); e abamectin (Vertimec 18 CE -- 50ml): Analisou-se a fitotoxicidade dos produtos testados, em relação à altura da planta, nº de folhas, número de flores e frutos ; diâmetro do caule e queimaduras ou injúrias foliares. As datas das avaliações foram: 01 dia antes das pulverizações, 15 dias e 30 dias após as mesmas. Os fungicidas Daconil BR, Reconil e Tecto 450; o fungicida acaricida Dithane PM; os acaricidas Carbax e Torque 500 SC; e o inseticida-acaricida Vertimec 18 CE, aplicados isoladamente, não afetaram o crescimento e a produção das plantas, nem causaram injúrias nas folhas das mesmas. A associação de fungicidas e fungicida-acaricida, com os acaricidas, ou inseticida-acaricida, não mostrou nenhum efeito fitotóxico sobre os parâmetros de crescimento avaliados, nem causaram queimaduras ou injúrias foliares.
Resumo:
Estudaram-se os efeitos fitotóxicos de fungicidas, acaricidas e inseticidas e algumas associações entre eles, em plantas de mamoeiros (Carica papaya L.) cv. Sunrise Solo Improved Line 72/12, em condições de verão, no município de São Mateus - ES, localizado na região produtora do Estado. O experimento foi arranjado em delineamento de blocos casualizados, com 4 repetições e 03 plantas úteis por parcela experimental. Foram utilizados os seguintes produtos, com as respectivas doses, para cada 100 l de água: abamectin (Vertimec 18 CE - 50 ml); dicofol + tetradiphon (Carbax - 200 ml), fenbutatin oxide (Torque 500 SC - 60 ml); mancozeb (Dithane PM - 200g); oxicloreto de cobre (Reconil - 400g) e thiabendazole (Tecto 450 - 100ml). Analisou-se a fitotoxicidade dos produtos em relação à altura da planta, nº de folhas, número de flores e frutos ; diâmetro do caule e queimaduras ou injúrias foliares. As medições e contagens foram feitas um dia antes das pulverizações, 15 e 30 dias após. Constatou-se que o Vertimec 18 CE, associado ao Reconil ou ao Tecto 450, ocasionou leves injúrias foliares, detectadas aos 15 dias após as pulverizações, que se tornaram praticamente imperceptíveis, aos 30 dias após as pulverizações; e que Dithane PM, Reconil, Tecto 450, Carbax, Torque 500 SC, Dithane PM + Carbax, Dithane PM + Torque 500 SC, Dithane PM + Vertimec 18 CE, Reconil + Carbax, Reconil + Torque 500 SC, Tecto 450 + Carbax e, Tecto 450 + + Torque 500 SC não interferiram nos parâmetros de desenvolvimento e de produção estudados, bem como não causaram injúrias ou queimaduras nas folhas dos mamoeiros.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
Thermal stability, thermal decomposition process, residual mass, temperature of glass transition (T-g) and temperature dependence of storage modulus (E'), were determined for latex membranes prepared from six clones of Hevea brasiliensis: IAC 331, IAC 332, IAC 333 and IAC 334 grown at experimental plantations of Instituto Agronomico de Campinas (IAC) in Votuporanga, São Paulo State, Brazil. Latex membranes from GT1 and RRIM 600 Asian matrix clones were used as references. The thermal behavior of latex membranes from genetically improved rubber trees was characterized using thermogravimetry/derivative thermogravimetry (TG/DTG), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The thermal behavior of latex from clones studied in the present work showed similar features of the clones previously reported (IAC 40, IAC 300, IAC 301, IAC 328, IAC 329 and IAC 330), with mass loss in four consecutive steps, except IAC 333, which showed an additional mass loss step. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Objective This study investigated how consumption of orange juice associated with aerobic training affected serum lipids and physical characteristics of overweight middle-aged womenMethods The experimental group consisted of 13 women who consumed 500 mL/d of orange juice and did 1 h aerobic training 3 times a week for 3 months The control group consisted of another 13 women who did the same aerobic training program but did not consume orange juiceResults At the end of the experiment the control group lost an average of 15% of fat mass (P < 0 05) and 25% of weight (P < 0 05) whereas the experimental group lost 11% of fat mass and 1 2% of weight (P < 0 05) Consumption of orange juice by the experimental group was associated with Increased dietary intake of vitamin C and folate by 126% and 61% respectively Serum LDL-C decreased 15% (P < 0 05) and HDL-C increased 18% (P < 0 05) in the experimental group but no significant change was observed in the control group Both groups improved the anaerobic threshold by 20% (P < 0 05) but blood lactate concentration decreased 27% in the experimental group compared to the 17% control group suggesting that experimental group has less muscle fatigue and better response to trainingConclusions The consumption of 500 mL/d of orange juice associated with aerobic training in overweight women decreased cardiovascular disease risk by reducing LDL-C levels and increasing HDL-C levels This association also decreased blood lactate concentration and increased anaerobic threshold showing some improvement in the physical performance (C) 2010 Elsevier B.V. All rights reserved
Resumo:
Tubercle bacilli may survive in unstained heat-fixed sputum smears and may be an infection risk to laboratory staff. We compared the effectiveness of 1% and 5% sodium hypochlorite, 5% phenol, 2% glutaraldehyde, and 3.7% formalin in killing Mycobacterium tuberculosis present in smears prepared from 51 sputum samples. The smears were decontaminated by the tube and slide techniques. Phenol at 5%, glutaraldehyde at 2%, and buffered formalin at 3.7% for 1 min (tube technique) or for 10 min (slide technique) were effective in decontaminating sputum smears and preserved cell morphology and quantitative acid-fast microscopy results.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Continuation methods have been long used in P-V curve tracing due to their efficiency in the resolution of ill-conditioned cases, with close to singular Jacobian matrices, such as the maximum loading point of power systems. Several parameterization techniques have been proposed to avoid matrix singularity and successfully solve those cases. This paper presents a simple geometric parameterization technique to overcome the singularity of the Jacobian matrix by the addition of a line equations located at the plane determined by a bus voltage magnitude and the loading factor. This technique enlarges the set of voltage variables that can be used to whole P-V curve tracing, without ill-conditioning problems and no need of parameter changes. Simulation results, obtained for large realistic Brazilian and American power systems, show that the robustness and efficiency of the conventional power flow are not only preserved but also improved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The analysis of alcoholic beverages for the important carcinogenic contaminant ethyl carbamate is very time-consuming and expensive. Due to possible matrix interferences, sample cleanup using diatomaceous earth (Extrelut) column is required prior to gas chromatographic and mass spectrometric measurement. A limiting step in this process is the rotary evaporation of the eluate containing the analyte in organic solvents, which is currently conducted manually and requires approximately 20-30 min per sample. This paper introduces the use of a parallel evaporation device for ethyl carbamate analysis, which allows for the simultaneous evaporation of 12 samples to a specified residual volume without manual intervention. A more efficient and, less expensive analysis is therefore possible. The method validation showed no differences between the fully-automated parallel evaporation and the manual operation. The applicability was proven by analyzing authentic spirit samples from Germany, Canada and Brazil. It is interesting to note that Brazilian cachacas had a relatively high incidence for ethyl carbamate contamination (55% of all samples were above 0.15 mg/l), which may be of public health relevance and requires further evaluation.