987 resultados para I-beam
Resumo:
Cardiac mast cells (MC) are apposed to capillaries within the heart and release renin and proteases capable of metabolizing angiotensins (Ang). Therefore, we hypothesized that mast cell degranulation could alter the rat coronary vascular responsiveness to the arterial delivered Ang I and Ang II, taking into account carboxypeptidase and chymase-1 activities. Hearts from animals that were either pretreated or not with systemic injection of the secretagogue compound 48/80 were isolated and mounted on a Langendorff apparatus to investigate coronary reactivity. The proteolytic activity of the cardiac perfusate from isolated hearts, pretreated or not with the secretagogue, toward Ang I and tetradecapeptide renin substrate was analyzed by HPLC. Coronary vascular reactivity to peptides was not affected by compound 48/80 pretreatment, despite the extensive amount of cardiac MC degranulation. Cardiac MC activation did not modify the generation of both Ang II and Ang 5-10 from Ang I by cardiac perfusate, activities that could be ascribed to MC carboxypeptidase and chymase-1, respectively. An aliskiren-resistant Ang I-forming activity was increased in perfusates from secretagogue-treated hearts. Thus, cardiac MC proteases capable of metabolizing angiotensins do not affect rat coronary reactivity to arterial delivered Ang I and II. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in radiotherapy. (c) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Serum levels of troponin and heart-related fraction of creatine kinase (CK-MB) mass are used as diagnostic and prognostic criteria in myocardial infarction, but the relation between those levels and-the necropsy-determined size of necrosis has not been tested in human beings. In this retrospective study, 1-cm-thick transverse sections of the ventricles were cut from the base to the apex in the necropsy hearts of 27 patients aged 47 to 86 years (mean 66, median 69; 19 men). Total and necrotic areas were measured using a computer-linked image analysis system. The weights of the necrotic areas were also calculated. The correlations of the areas and weights of necrotic myocardium with the highest serum values of CK-MB mass and troponin 1, which had been quantified during life by chemiluminescence immunoassays, were verified by Pearson`s test; results were considered significant at p <= 50.05. Significant correlations were detected between CK-MB mass peak and infarct size (r = 0.63, p < 0.01) and weight (r = 0.69, p < 0.01) and between CK-MB mass and highest troponin level (r = 0.73, p < 0.01); however, the correlations between highest troponin level and myocardial infarct size (r = 0.31, p = 0.11) and weight (r = 0.35, p = 0.07) were small and nonsignificant. In conclusion, despite the well-established role of serum levels of troponin as a diagnostic tool for myocardial infarction, their highest values showed poor correlations with the extent of infarct. In contrast, the highest serum level of CK-MB mass was well correlated with myocardial infarct size. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
Background: Ehrlichiosis is a multisystemic disease with the potential to cause cardiomyocyte injury in naturally infected dogs. Hypothesis: Myocardial injury occurs in dogs infected with Ehrlichia canis. Animals: One-hundred and ninety-four dogs from Brazil with clinical and laboratory abnormalities indicative of ehrlichiosis. Sixteen healthy dogs served as controls. Methods: Electrocardiogram, echocardiogram, noninvasive blood pressure measurement, and serum cardiac troponin I (cTnI) concentrations were evaluated. Serologic assays and PCR determined the exposure and infection status for E. canis, Anaplasma spp., Babesia canis vogeli, Bartonella spp., Borrelia burgdorferi, Dirofilaria immitis, Ehrlichia chaffeensis, Ehrlichia ewingii, Leishmania chagasi, and spotted-fever group Rickettsia. Dogs were assigned to groups according to PCR status: E. canis infected, infected with other vector-borne organisms, sick dogs lacking PCR evidence for infection, and healthy controls. Results: E. canis-infected dogs had higher serum cTnI concentrations than controls (median: 0.04 ng/dL; range 0.04-9.12 ng/dL; control median: 0.04 ng/dL; range: 0.04-0.10 ng/dL; P = .012), and acute E. canis infection was associated with myocardial injury (odds ratio [OR]: 2.67, confidence interval [CI] 95%: 1.12-6.40, P = .027). Severity of anemia was correlated with increased risk of cardiomyocyte damage (r = 0.84, P < .001). Dogs with clinical signs of systemic inflammatory response syndrome (SIRS) were at higher risk for myocardial injury than were other sick dogs (OR: 2.55, CI 95%: 1.31-4.95, P = .005). Conclusions and Clinical Importance: Acute infection with E. canis is a risk factor for myocardial injury in naturally infected Brazilian dogs. Severity of anemia and SIRS might contribute to the pathophysiology of myocardial damage.
Resumo:
Contents This study aimed to evaluate the effect of the exogenous recombinant bovine somatotropin (rbST) on plasma concentrations of insulin-like growth factor I (IGF-I), insulin and semen quality of bulls. Twenty bulls (Aberdeen Angus and Brangus) were divided by breed into two groups. Placebo group was injected with NaCl 0.9% (s.c.) and treatment group with rbST (s.c., 500 mg) at days 0 and 14 of the experiment. Immediately after semen collection, blood samples were taken on days 0, 14, 28, 42 and 56 of the experiment. Semen was also collected on day 70 of the experiment. Evaluation of sperm motility was performed at pre-freezing and post-thawing stage, whereas assessment of sperm membrane integrity was performed after freezing and thawing. Analysis of data revealed that the effect of treatment and treatment-by-collection day on plasma concentrations of IGF-I and insulin was not significant. However, mean plasma concentrations of IGF-I and insulin were affected (p < 0.0001) by days of blood sampling. Effect of treatment and treatment-by-collection day on motility of spermatozoa was similar (p > 0.05) at pre-freezing and post-thawing stage. Intactness of plasmalemma and tail membrane of spermatozoa at post-thawing stage was higher (p < 0.05) in rbST-treated group than in control. In conclusion, rbST did not affect plasma concentrations of IGF-I and insulin, however, it did improve post-thaw sperm membrane integrity.
Resumo:
Zirconia (ZrO(2)) is a bioinert, strong, and tough ceramic, while titania (TiO(2)) is bioactive but has poor mechanical properties. It is expected that ZrO(2)-TiO(2) mixed ceramics incorporate the individual properties of both ceramics, so that this material would exhibit better biological properties. Thus, the objective of this study was to compare the biocompatibility properties of ZrO(2)-TiO(2) mixed ceramics. Sintered ceramics pellets, obtained from powders of TiO(2), ZrO(2), and three different ZrO(2)-TiO(2) mixed oxides were used. Roughnesses, X-ray diffraction, microstructure through SEM, hardness, and DRIFT characterizations were performed. For biocompatibility analysis cultured FMM1 fibroblasts were plated on the top of disks and counted in SEM micrographs 1 and 2 days later. Data were compared by ANOVA complemented by Tukey`s test. All samples presented high densities and similar microstructure. The H(2)O content in the mixed ceramics was more evident than in pure ceramics. The number of fibroblasts attached to the disks increased significantly independently of the experimental group. The cell growth on the top of the ZrO(2)-TiO(2) samples was similar and significantly higher than those of TiO(2) and ZrO(2) samples. Our in vitro experiments showed that the ZrO(2)-TiO(2) sintered ceramics are biocompatible allowing faster cell growth than pure oxides ceramics. The improvement of hardness is proportional to the ZrO(2) content. Thus, the ZrO(2)-TiO(2) sintered ceramics could be considered as potential implant material. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 94B: 305-311, 2010.
Resumo:
Introduction: The aim of the present study was to test the accuracy of small-volume cone-beam computed tomography (CBCT) scanning in the detection of horizontal root fractures and to assess the influence of a metallic post. Methods: Forty teeth were divided into four groups based on the presence of metallic posts and horizontal root fracture. The teeth were examined by small-volume CBCT scanning at 0.2-mm voxel resolution. Three observers analyzed the samples for the presence of a horizontal root fracture. Sensitivity and specificity were calculated. Results: High values for accuracy (73%-88%) were obtained in the groups without a metallic post, and statistically significant differences were found when the group with a metallic post has been observed (55%-70%). Intraobserver agreement also showed statistically significant differences in the groups with a metallic post. Conclusions: Small-volume CBCT scanning showed high accuracy in detecting horizontal root fracture without a metallic post. However, the presence of a metallic post significantly reduced the specificity and sensitivity of this examination. (J Endod 2011;37:1456-1459)
Resumo:
The calcifying cystic odontogenic tumour (CCOT) is a rare benign cystic neoplasm not infrequently associated with odontoma. This report documents a case of CCOT associated with compound odontoma arising in the anterior maxilla in a 25-year-old woman. Conventional radiographs showed a large calcified mass with poorly visualized radiolucent margins. The extent and condition of the internal structure of the CCOT associated with odontoma was able to be determined based on radiographic findings from cone beam computed tomography. This advanced image technique proved to be extremely useful in the radiographic assessment of this particular neoplasm of the jawbones.
Resumo:
The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.
Resumo:
Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)
Resumo:
Nasopharyngeal angiofibroma (NA) is a rare vascular benign nonencapsulated neoplasm, characterized by local aggressiveness and destructive potential, typically diagnosed in adolescent males. We report a case of NA affecting a 15-year-old male that presented with a persistent nasal obstruction and epistaxis with 1 year of evolution. Clinical and radiological patterns pointed out a differential diagnosis of NA. Arteriography demonstrates the vascular support of the tumor and evinces the embolization of the internal maxillary artery. The surgical approach was procedure by Le Fort I osteotomy exposing the tumor and promoting easy access for posterior removal. The surgery was carried out without hemorrhagic problems. The maxilla was fixed in the original position with 4 L-shape plaques. Histopathological findings supported the diagnosis of NA. The patient presented after 8 months of postoperative follow-up, without clinical signs of recurrence or residual tumor and without palatal or maxillary teeth paresthesia.
Resumo:
The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)