Comparison of MB fraction of creatine kinase mass and troponin I serum levels with necropsy findings in acute myocardial infarction


Autoria(s): COSTA, Thiago Nogueira; STRUNZ, Cia Maria Cassaro; NICOLAU, Jose Carlos; GUTIERREZ, Paulo Sampaio
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2008

Resumo

Serum levels of troponin and heart-related fraction of creatine kinase (CK-MB) mass are used as diagnostic and prognostic criteria in myocardial infarction, but the relation between those levels and-the necropsy-determined size of necrosis has not been tested in human beings. In this retrospective study, 1-cm-thick transverse sections of the ventricles were cut from the base to the apex in the necropsy hearts of 27 patients aged 47 to 86 years (mean 66, median 69; 19 men). Total and necrotic areas were measured using a computer-linked image analysis system. The weights of the necrotic areas were also calculated. The correlations of the areas and weights of necrotic myocardium with the highest serum values of CK-MB mass and troponin 1, which had been quantified during life by chemiluminescence immunoassays, were verified by Pearson`s test; results were considered significant at p <= 50.05. Significant correlations were detected between CK-MB mass peak and infarct size (r = 0.63, p < 0.01) and weight (r = 0.69, p < 0.01) and between CK-MB mass and highest troponin level (r = 0.73, p < 0.01); however, the correlations between highest troponin level and myocardial infarct size (r = 0.31, p = 0.11) and weight (r = 0.35, p = 0.07) were small and nonsignificant. In conclusion, despite the well-established role of serum levels of troponin as a diagnostic tool for myocardial infarction, their highest values showed poor correlations with the extent of infarct. In contrast, the highest serum level of CK-MB mass was well correlated with myocardial infarct size. (c) 2008 Elsevier Inc. All rights reserved.

Identificador

AMERICAN JOURNAL OF CARDIOLOGY, v.101, n.3, p.311-314, 2008

0002-9149

http://producao.usp.br/handle/BDPI/25137

10.1016/j.amjcard.2007.08.037

http://dx.doi.org/10.1016/j.amjcard.2007.08.037

Idioma(s)

eng

Publicador

EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC

Relação

American Journal of Cardiology

Direitos

restrictedAccess

Copyright EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC

Palavras-Chave #ELECTROCARDIOGRAPHIC-ANATOMIC CORRELATIONS #12-LEAD ELECTROCARDIOGRAM #SIZE #Cardiac & Cardiovascular Systems
Tipo

article

original article

publishedVersion