704 resultados para Disinfected impressions


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74°C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (α=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, the occurrence of Othonella araguaiana Mendes, a rare bivalve species is reported for the fi rst time in the Pinzonella illusa biozone, Middle Permian Corumbataí Formation, in the State of São Paulo. This species was originally described in coeval rocks of the Estrada Nova Formation (= Corumbataí) from the Alto Araguaia and Alto Garças regions, State of Mato Grosso. The specimens of O. araguaiana were found in the base of a bioclastic sandstone bed, a proximal tempestite, in the middle of the Corumbataí Formation, in the city of Rio Claro, São Paulo State. The silicifi ed shells and internal molds are well preserved, showing impressions of muscle scars and other internal anatomic characters (e.g., hinge), never illustrated by previous authors. In his original description, Mendes (1963) called attention to the similarity between O. araguaiana and Terraia aequilateralis, a common veneroid of the Corumbataí Formation. Conversely, Runnegar and Newell (1971) suggested that O. araguaiana belongs to Megadesmidae, being a junior synonym of Plesiocyprinella carinata (the commonest megadesmid of the Passa Dois Group). Our study indicates that O. araguaiana is indeed a megadesmid, but is distinct from the P. carinata. The new occurrence of O. araguaiana demonstrates that a) the paleobiogeographic distribution of this species is wider than previously thought (that it was restricted to the northern part of Paraná Basin, Mato Grosso State); b) the molluscan fauna of the Corumbataí Formation (P. illusa biozone) in the State of São Paulo is more diverse and dominated by megadesmids; and c) the composition of the molluscan fauna of the Corumbataí Formation in Alto Garças, State of Mato Grosso, is essentially the same as that of the P. illusa biozone of the eastern margin of the Paraná Basin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated the effects of disinfection and aging on the hardness of silicones containing opacifiers and intended for use in facial prosthetics. A total of 90 samples were produced using a cylindrical metal mold 3 mm in height and 30 mm in diameter. The samples were fabricated from Silastic MDX 4-4210 silicone in three groups: GI contained no opacifier, GII contained barium sulfate (Ba), and GIII contained titanium dioxide (Ti). The samples were disinfected using effervescent tablets (Ef), neutral soap (Ns), or 4% chlorhexidine (Cl) 3 times a week for 60 days. After this period the samples underwent 1,008 hours of accelerated aging. The hardness was measured using a durometer immediately following the disinfection period and after 252, 504, and 1,008 hours of aging. The data were statistically analyzed using 3-way ANOVA and the Tukey test (p < .05). The GIII group exhibited the greatest variation in hardness regardless of elapsed time. All groups displayed greater hardness after 1,008 hours of accelerated aging independent of disinfectant type. All of the hardness values were within the clinically acceptable range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficacy of a pouring technique for implant-supported prostheses impressions. A metallic matrix (control group) with two implants positioned at 90 and 65 degrees was fabricated. The matrix was submitted to the direct transfer impression technique. In group CP (conventional pouring - n = 10), casts were obtained by the conventional pouring technique. In group EP (experimental pouring - n = 10), the analogs were embraced with latex tubes before the first pouring and then submitted to a second pouring. Vertical misfit and implants/analogs inclinations were evaluated. Data were analyzed by analysis of variance and Tukey's test (p < .05). Results demonstrated significant difference (p < .05) between control and experimental groups for misfit measurement in perpendicular implant/analog and between control group and group EP in leaning implant/analog. Considering inclination, there were significant differences (p < .05) between control and experimental groups for leaning analogs. Independently of the pouring technique, perpendicular implants produced more accurate casts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Palatal rugoscopy, or palatoscopy, is the process by which human identification can be obtained by inspecting the transverse palatal rugae inside the mouth. Aim: This study evaluated a digital method for human identification using palatoscopy, by comparing photographs of the palate against the images of cast models of the maxilla photographed with and without highlighting of the palatal rugae. Methods: Condensation silicone impressions were made from the upper arches of 30 adult subjects of both genders and their palates were then photographed. The first impression was made with heavy silicone, the second impression with light silicone, and then the models were cast in improved type IV dental stone. The casts were photographed, the palatal rugae of each one were highlighted with a pencil, and then the models were photographed again. Using a free image-editing software, the digital photographs were overlapped over the images of the palatal rugae of the models with and without highlighting of the palatal rugae, in order to identify the pairs. Results: The result of overlapping the digital photographs with the images of the models without highlighted palatal rugae resulted in 90% positive identification. For the overlapping of the digital photographs with the images of models with highlighted palatal rugae, there was 100% positive identification. Conclusions: The digital method evaluated in this study was proven effective for human identification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the microbial contamination in samples of radiographic developing and fixing solutions, radiographic processing water, dental unit waterlines and dental office's external water supply. Methods: Samples of 50 private dental offices and 20 dental offices of the School of Dentistry de Araçatuba-UNESP were collected. The samples were subjected to neutralization of the residual inhibitory agents followed by pre-enrichment in peptone water and EVA broth and were inoculated in selective and non-selective culture media. The DNA of the samples was extracted and the presence of superinfectant microorganisms was evaluated by PCR. The differences in the prevalence of the microorganisms in the samples of the solutions were analyzed by repeated-measures analysis of variance for category data, while the Chi-Square and Mann-Whitney tests were used to evaluate the existence of associations between the total number of heterotrophic microorganisms and infection control protocols. The significance level was set at 5%. Results: Samples of radiographic fixing solution presented a remarkably less frequent contamination than radiographic developing solution and radiographic processing water. The latter exhibited microorganisms typically originated from the oral microbiota and human skin as well as microorganisms frequently found in dental unit waterlines. There was less contamination of radiographic processing water in the dental offices where the x-ray film packets were disinfected before processing or were covered by a plastic film. Additionally, all samples of dental office's external water supply were drinkable. Conclusion: Covering the x-ray film packets with a plastic film protection barrier was proven the best manner to reduce the contamination of the evaluated solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effect of disinfection and accelerated ageing on the dimensional stability and detail reproduction of a facial silicone with different types of nanoparticle. A total of 60 specimens were fabricated with Silastic MDX 4-4210 silicone and they were divided into three groups: colourless and pigmented with nanoparticles (make-up powder and ceramic powder). Half of the specimens of each group were disinfected with Efferdent tablets and half with neutral soap for 60 days. Afterwards, all specimens were subjected to accelerated ageing. Both dimensional stability and detail reproduction tests were performed after specimen fabrication (initial period), after chemical disinfection, and after accelerated ageing periods (252, 504 and 1008 hours). The dimensional stability test was conducted using AutoCAD software, while detail reproduction was analysed using a stereoscope magnifying glass. Dimensional stability values were statistically evaluated by analysis of variance (ANOVA) followed by Tukey's test (p < 0.01). Detail reproduction results were compared using a score. Chemical disinfection and also accelerated ageing affected the dimensional stability of the facial silicone with statistically significant results. The silicone's detail reproduction was not affected by these two factors regardless of nanoparticle type, disinfection and accelerated ageing. © 2012 Informa UK, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Making an artificial iris with an aesthetically acceptable color is an important aspect of ocular rehabilitation. This work evaluated the influence of different disinfecting solutions on changes to the color of artificial irises used in ocular prostheses. Fifty samples simulating ocular prostheses were produced with cobalt blue artificial irises and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite, and 4% chlorhexidine. The samples were disinfected for 120 days and subjected to a color readings by spectrophotometry, using the CIE L*a*b* system, before the disinfection period (B), after 60 days of disinfectant exposure (T 1), and after 120 days of disinfectant exposure (T 2). Color differences (ΔE) were calculated for the intervals between T 1 and B (T 1B), and between T 2 and B (T 2B). The data were evaluated by analysis of variance and the Tukey Honestly Significantly Different (α = 0.05). All disinfectant groups exhibited color changes. The mean color change observed for all groups overall during T 2B (ΔE = 3.51) was significantly greater than that observed during T 1B (ΔE = 2.10). All groups exhibited greater color change for the b* values when compared to the a* and L* values. There were no significant differences between the disinfectant groups. It can be concluded that the time period of disinfection and storage significantly affected the stability of artificial iris color, independent of the disinfectant used. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Latent fingerprints are routinely found at crime scenes due to the inadvertent contact of the criminals' finger tips with various objects. As such, they have been used as crucial evidence for identifying and convicting criminals by law enforcement agencies. However, compared to plain and rolled prints, latent fingerprints usually have poor quality of ridge impressions with small fingerprint area, and contain large overlap between the foreground area (friction ridge pattern) and structured or random noise in the background. Accordingly, latent fingerprint segmentation is a difficult problem. In this paper, we propose a latent fingerprint segmentation algorithm whose goal is to separate the fingerprint region (region of interest) from background. Our algorithm utilizes both ridge orientation and frequency features. The orientation tensor is used to obtain the symmetric patterns of fingerprint ridge orientation, and local Fourier analysis method is used to estimate the local ridge frequency of the latent fingerprint. Candidate fingerprint (foreground) regions are obtained for each feature type; an intersection of regions from orientation and frequency features localizes the true latent fingerprint regions. To verify the viability of the proposed segmentation algorithm, we evaluated the segmentation results in two aspects: a comparison with the ground truth foreground and matching performance based on segmented region. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the development and integration of an user interface (UI) framework based on various current input devices that take advantage of our ergonomics. The purpose is to teleoperate a holonomic robot using upper member gestures and postures for studying the suitable of such interfaces when programming and interacting with a mobile robot. As performance vary from UI to UI the framework is focused to be used as a complementary industrial or didactic tool thus, changing how inexperience users tackle their first impressions when working with mobile robots while performing simple gesture-based teleoperation tasks. © 2012 ICROS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Ocular prosthesis materials should have specific properties for their indication and durability; therefore, it is important to investigate their physical behaviour when affected by several disinfectants. Objectives: This study evaluated the influence of different disinfecting solutions on the microhardness and surface roughness of acrylic resins for ocular prosthesis. Materials and Methods: Fifty samples simulating ocular prostheses were fabricated with N1 resin and colourless resin and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite (HYC) and 4% chlorhexidine (CHX). Samples were stored in saline solution at 37°C and disinfected during 120 days. Both microhardness and roughness were investigated before, after 60 days and 120 days of disinfection and storage. Microhardness was measured using a microhardner and the roughness with a roughness device. Results: N1 resin showed lower microhardness when compared with colourless resin (p < 0.05). HYC and CHX groups exhibited the highest change of microhardness and roughness values (p < 0.05). An increase in roughness and reduction in microhardness of ocular acrylic resins were observed after both periods of disinfection and storage (p < 0.05). Conclusion: Both disinfection/storage periods affected the microhardness and roughness values of the samples. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The consumer market demands food without pesticide residues. Therefore, this study focused on evaluating the control of green mold in Pera orange trees with biocontrol agents (Bacillus subtilis, Bacillus licheniformis and Bacillus subtilis (QST 713)), associated or not with heat treatment. The fruit was obtained in packinghouse before processing, being washed and disinfected with the use of Sodium Hypochlorite. Fruits submitted to these treatments were stored from 11 to 28 days at temperature of 10 °C and RH 90%±5 or for eight days at 20 °C and 90%±5. In general, the heat treatment reduced the disease severity determine by the area under the disease progress curve in the fruit and the incidence of natural postharvest disease in Pera oranges. On the other hand, biocontrol agents did not control the disease, showing that the organisms tested did not present curative activity against the green mold.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins. © 2013 Informa UK Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.