Hardness evaluation of prosthetic silicones containing opacifiers following chemical disinfection and accelerated aging


Autoria(s): Goiato, Marcelo Coelho; Haddad, Marcela Filié; Santos, Daniela Micheline dos; Pesqueira, Aldieris Alves; Moreno, Amália
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

27/05/2014

27/05/2014

01/07/2010

Resumo

We evaluated the effects of disinfection and aging on the hardness of silicones containing opacifiers and intended for use in facial prosthetics. A total of 90 samples were produced using a cylindrical metal mold 3 mm in height and 30 mm in diameter. The samples were fabricated from Silastic MDX 4-4210 silicone in three groups: GI contained no opacifier, GII contained barium sulfate (Ba), and GIII contained titanium dioxide (Ti). The samples were disinfected using effervescent tablets (Ef), neutral soap (Ns), or 4% chlorhexidine (Cl) 3 times a week for 60 days. After this period the samples underwent 1,008 hours of accelerated aging. The hardness was measured using a durometer immediately following the disinfection period and after 252, 504, and 1,008 hours of aging. The data were statistically analyzed using 3-way ANOVA and the Tukey test (p < .05). The GIII group exhibited the greatest variation in hardness regardless of elapsed time. All groups displayed greater hardness after 1,008 hours of accelerated aging independent of disinfectant type. All of the hardness values were within the clinically acceptable range.

Formato

303-308

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242010000300008

Brazilian Oral Research, v. 24, n. 3, p. 303-308, 2010.

1806-8324

1807-3107

http://hdl.handle.net/11449/71773

S1806-83242010000300008

2-s2.0-77957931277

2-s2.0-77957931277.pdf

Idioma(s)

eng

Relação

Brazilian Oral Research

Direitos

openAccess

Palavras-Chave #Disinfection #Hardness #Maxillofacial prosthesis #antiinfective agent #barium sulfate #dimeticone #titanium #chemistry #disinfection #drug effect #hardness #materials testing #maxillofacial prosthesis #surface property #time #Anti-Infective Agents #Barium Sulfate #Dimethylpolysiloxanes #Hardness Tests #Materials Testing #Maxillofacial Prosthesis #Surface Properties #Time Factors #Titanium
Tipo

info:eu-repo/semantics/article