991 resultados para Length measurement
Resumo:
OBJECTIVE: To identify characteristics of the hospitalizations due to ischemic heart disease (IHD) made by the Single Health System -- "Sistema Único de Saúde (SUS) in Brazil from 1993 to 1997. METHODS: The information used came from records of permissions for hospitalization due to IHD (diseases codified from 410 to 414 by the International Disease Classification -- 9th Revision) furnished by the data bank DATASUS. The material studied was classified according to age, sex and length of hospitalization of the patients, and expenses to the system for IHD. RESULTS: IHD represents 1.0% of total hospitalizations. Angina pectoris was the most frequent type, occurring in 53.3% of the cases, followed by acute myocardial infarct (26.6%). This later was more frequent in men and angina in women . The majority of patients with IHD stayed hospitalized from 5 to 8 days. In the years of 1997 the expenses due to hospital treatment for IHD reach to 0.01% of Brazil's Gross Internal Product. In the studied period (1993-1997), IHD was responsible by 1.0% of hospitalizations, however it was 3.3% of the expenses of SUS. CONCLUSION: IHD is an important cause of hospitalization by the SUS; it has a rather high cost, indicating the need for preventive measures aimed at reducing exposure to risk factors and to decrease the incidence of this group of diseases in the nation.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
Introdução: São escassas as medidas objetivas, válidas e consistentes da função sensoriomotora do complexo articular do ombro (CAO). Objetivos: desenvolvimento e validação de um protocolo de avaliação sensoriomotora do CAO. Materiais e métodos: 40 Sujeitos (16 atletas e 24 não atletas) completaram 6 momentos de teste, 3 por cada um de 2 investigadores. Em cada momento avaliou-se a NPA pelo Biodex System 3, na elevação do braço no plano da omoplata a 80º e 160º, e na rotação externa (RE) a 45º e 80º , bem como o controlo postural do CAO avaliou-se pela plataforma Rsscan. Resultados/Discussão: Todas as variáveis apresentaram estabilidade temporal, exceto os erros a 80º na RE (p=0,021) e 80º no PO (p=0,006), nos atletas, para o Investigador 1, e as componentes do CP nos não atletas, para o investigador 2. Os ICC’s foram globalmente baixos, apresentando valores moderados no grupo de não atletas, para o Investigador 2, no comprimento (0,862) e velocidade média do CP (0,852). Excluindo a área do CP no grupo de não atletas (p=0,030), não houve diferenças significativas nas médias entre observadores. Verificaram-se correlações fortes entre as componentes do CP, mas não ocorreram correlações fortes entre estas e as da NPA. Conclusões: Os resultados poucos consistentes, não permitem retirar conclusões sólidas, impossibilitando assumir o protocolo como fiável e válido na avaliação sensoriomotora do CAO.
Resumo:
Software engineering, software measurement, software process engineering, capability, maturity
Resumo:
Social intelligence
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2009
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2010
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2011
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012
Resumo:
The present study aims to compare the buccal apparatus and gastrointestinal tract of early life stages of Centropomus undecimalis (Bloch, 1792), and relate them to its diet. A total of 190 individuals collected with a channel net in the Catuama estuary (07º40'9.9''S, 34º50'36.7''W), northern coast of the state of Pernambuco, were examined. Morphometrical and meristic data were analyzed for the two initial developmental periods (larval and juvenile). Their digestive tube was morphologically characterized and its content identified. The longest transverse axis of food items was measured, and compared to the standard length (SL) and mouth gape size (D) of the individuals. Body measurement regressions differed significantly (p<0.001) between larvae and juveniles. The stomachs with food content (n=118 individuals) presented a proportion of 62% full and 30% empty (being 8% damaged). They differed in relation to the fullness level and presented a coiled shape when empty. The number of food items in relation to SL and D did not present an evident correlation. Larvae (SL<10 mm) feed on small copepods, while juveniles (SL=11.1 to 64.7 mm) ingest larvae of various decapod species, showing a distinct diet between these initial developmental stages.
Resumo:
The filling length of an edge-circuit η in the Cayley 2-complex of a finite presentation of a group is the minimal integer length L such that there is a combinatorial null-homotopy of η down to a base point through loops of length at most L. We introduce similar notions in which the full-homotopy is not required to fix a base point, and in which the contracting loop is allowed to bifurcate. We exhibit a group in which the resulting filling invariants exhibit dramatically different behaviour to the standard notion of filling length. We also define the corresponding filling invariants for Riemannian manifolds and translate our results to this setting.