915 resultados para LED Lamps
Resumo:
This study evaluated in vitro the shear bond strength of brackets bonded with xenon plasma arc light, light-emitting diode (LED) and conventional halogen light using different curing times. Brackets were bonded to the buccal surface of 60 human maxillary premolars allocated to five groups. In groups 1 and 2, the resin was cured with the plasma arc for three and six seconds (s), respectively; in groups 3 and 4, the LED was used for five and ten s, respectively; and in group 5, the halogen light was used for 40 s. The specimens were stored in water for 24 hours and subjected to a shear force until bracket failure. The debonding pattern was classified according to the adhesive remnant index (ARI). The results were assessed by Anova and the SNK post-hoc test. No differences were detected among groups 2, 4 and 5, which showed higher averages than groups 1 and 3, which were not different between themselves. The ARI scores showed no differences among the three types of light sources in all times tested. Plasma arc and LED lights can be used with shorter curing times, within certain limits, than conventional halogen light for bonding orthodontic brackets, without decreasing bond strength.
Resumo:
The aim of this study was to compare the bleaching efficacy of 35% hydrogen peroxide and 15% hydrogen peroxide with nitrogen-doped titanium dioxide catalysed by an LED-laser hybrid light. We studied 70 patients randomized to two groups. Tooth shade and pulpal sensitivity were registered. Group 1: 15% hydrogen peroxide with nitrogen-doped titanium dioxide. Group 2: 35% hydrogen peroxide. Both groups were activated by an LED-laser light. No significant differences were seen in shade change immediately, one week or one month after treatment (p > 0.05). Differences were seen in pulpal sensitivity (p < 0.05). The use of an LED-laser hybrid light to activate 15% hydrogen peroxide gel with N_TiO2 permits decreasing the peroxide concentration with similar aesthetic results and less pulpal sensitivity than using 35% hydrogen peroxide for bleaching teeth.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to assess the influence of the quantity of coloring agent on the bleaching efficiency of gels containing 35% H2O2. Sixty human third molars were sectioned mesiodistally, darkened in a coffee solution and sectioned in the occlusal-cervical direction, resulting in mesial (not bleached) and distal halves (bleached). They were distributed into three groups: Whiteness HP, Total Bleach, and Whiteform Perox Red Gel; and subdivided into four sub-groups: no coloring agent, manufacturer's standard, double the standard, and triple the standard. The gels were activated with light-ermitting diode/laser appliances. The images were analyzed with the Adobe Photoshop program (deltaEL*a*b*). The variation was submitted to the ANOVA test (two factors: type of gel and quantity of coloring agent) and Tukey test. Differences were observed for the quantity of coloring agent. The mean (+/-SD) was determined for each quantity of coloring used: no coloring agent -6.85 (+/-2.26)a, manufacturer's standard -794 (+/-2.55)ab, double the standard -8.65 (+/-2.47)b, triple the standard -9.05 (+/-2.72)b. In conclusion, the standard quantity of coloring agent did not provide significantly more intense bleaching than when it was completely absent. The use of double and triple the amount provided greater bleaching than that observed for the gel without coloring agent. No significant differences were observed between the tested gels.
Resumo:
This aim of the present study was to evaluate the pulp chamber penetration of 35% hydrogen peroxide activated by LED (light-emitting diode) or Nd:YAG laser in bovine teeth, after an in-office bleaching technique. Forty-eight bovine lateral incisors were divided into four groups, acetate buffer was placed into the pulp chamber and bleaching agent was applied as follows: for group A (n = 12), activation was performed by LED; for group B (n = 12), activation was performed by Nd:YAG laser (60 mJ, 20 Hz); group C (n = 12) received no light or laser activation; and the control group (n = 12) received no bleaching gel application or light or laser activation. The acetate buffer solution was transferred to a glass tube and Leuco Crystal Violet and horseradish peroxidase were added, producing a blue solution. The optical density of this solution was determined spectrophotometrically and converted into microgram equivalents of hydrogen peroxide. The results were analysed using ANOVA and Tukey's test (5%). It was verified that the effect of activation was significant, as groups activated by LED or laser presented greater hydrogen peroxide penetration into the pulp chamber (0.499 +/- 0.622 microg) compared with groups that were not (0.198 +/- 0.218 microg). There was no statistically significant difference in the penetration of hydrogen peroxide into the pulp chamber between the two types of activation (LED or laser). The results suggest that activation by laser or LED caused an increase in hydrogen peroxide penetration into the pulp chamber.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Math in the Middle Institute Partnership, Action Research Project Report, In partial fulfillment of the MAT Degree. Department of Mathematics. University of Nebraska-Lincoln. July 2009.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aims of this study were to evaluate the effects of PhotogemA (R)-mediated photosensitization on rat palatal mucosa and the biodistribution of the photosensitizer in this tissue. A solution of PhotogemA (R) (500 or 1000 mg/l) was applied to the palatal mucosa for 30 min and the exposure time to blue LED (460 nm) was 20 min (144 J/cm(2)). At 0, 1, 3, and 7 days, palatal mucosa was photographed for macroscopic analysis. After killing, the palate was removed for microscopic analysis. Thermal mapping evaluated temperature change in the tissue during irradiation. All experimental groups revealed intact mucosa in the macroscopic analysis. Tissue alterations were observed microscopically for only four out of 80 animals subjected to PDT. Fluorescence emitted by PhotogemA (R) was identified and was limited to the epithelial layer. A temperature increase from 35 to 41A degrees C was recorded. PhotogemA (R)- mediated PDT was not toxic to the rat palatal mucosa.
Resumo:
In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.
Resumo:
In a homemade UV-Ozone generator, different ignition tubes extracted from HID mercury vapor lamps were investigated, namely: 80, 125, 250 and 400 watts. The performance of the generator in function of the type of the ignition lamp was monitored by the measurements of the ozone concentration and the temperature increment. The results have shown that the 400 W set up presented the highest ozone production, which was used in the treatment of indium tin oxide (ITO) films. Polymer light emitting diodes were assembled using ITO films, treated for 10, 20 and 30 min, as an anode. The overall results indicate improvement of the threshold voltage (reduction) and electroluminescence of these devices.