UV-Ozone Generation from Modified High Intensity Discharge Mercury Vapor Lamps for Treatment of Indium Tin Oxide Films
Contribuinte(s) |
UNIVERSIDADE DE SÃO PAULO |
---|---|
Data(s) |
06/11/2013
06/11/2013
2012
|
Resumo |
In a homemade UV-Ozone generator, different ignition tubes extracted from HID mercury vapor lamps were investigated, namely: 80, 125, 250 and 400 watts. The performance of the generator in function of the type of the ignition lamp was monitored by the measurements of the ozone concentration and the temperature increment. The results have shown that the 400 W set up presented the highest ozone production, which was used in the treatment of indium tin oxide (ITO) films. Polymer light emitting diodes were assembled using ITO films, treated for 10, 20 and 30 min, as an anode. The overall results indicate improvement of the threshold voltage (reduction) and electroluminescence of these devices. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES) Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) Grupo de Eletronica Molecular Instituto Astronomico e Geofisico of the University of Sao Paulo |
Identificador |
OZONE-SCIENCE & ENGINEERING, PHILADELPHIA, v. 34, n. 2, Special Issue, pp. 129-135, MAR-APR, 2012 0191-9512 http://www.producao.usp.br/handle/BDPI/42029 10.1080/01919512.2011.649132 |
Idioma(s) |
eng |
Publicador |
TAYLOR & FRANCIS INC PHILADELPHIA |
Relação |
OZONE-SCIENCE & ENGINEERING |
Direitos |
closedAccess Copyright TAYLOR & FRANCIS INC |
Palavras-Chave | #OZONE #MERCURY LAMP #INDIUM TIN OXIDE #POLYMERIC ELECTROLUMINESCENT DEVICE #DEVICES #ENGINEERING, ENVIRONMENTAL #ENVIRONMENTAL SCIENCES |
Tipo |