988 resultados para WaDe equazione onda keypoint detector corrispondenze punti salienti elaborazione immagini piramide


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the planning, implementation, and initial results of the first planned move of the default position of spectra on the Hubble Space Telescope's Cosmic Origins Spectrograph (COS) Far Ultraviolet (FUV) cross-delay line detector. This was motivated by the limited amount of charge that can be extracted from the microchannel plate due to gain sag at any one position. Operations at a new location began on July 23, 2012, with a shift of the spectrum by +3.5"(corresponding to ~ 41 pixels or ~ 1 mm) in a direction orthogonal to the spectral dispersion. Operation at this second "lifetime position" allows for spectra to be collected which are not affected by detector artifacts and loss of sensitivity due to gain sag. We discuss programs designed to enable operations at the new lifetime position; these include determinations of operational high voltage, measuring walk corrections and focus, confirming spectrum placement and aperture centering, and target acquisition performance. We also present results related to calibration of the new lifetime position, including measurements of spectral resolution and wavelength calibration, flux and flat field calibration, carryover of time-dependent sensitivity monitoring, and operations with the Bright Object Aperture (BOA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed characterization of a X-ray Si(Li) detector was performed to obtain the energy dependence of efficiency in the photon energy range of 6.4 - 59.5 keV. which was measured and reproduced by Monte Carlo (MC) simulations. Significant discrepancies between MC and experimental values were found when lhe manufacturer parameters of lhe detector were used in lhe simulation. A complete Computerized Tomagraphy (CT) detector scan allowed to find the correct crystal dimensions and position inside the capsule. The computed efficiencies with the resulting detector model differed with the measured values no more than 10% in most of the energy range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doppler Broadening Spectroscopy of the large Ge crystal of an HPGe detector was perforrned using positrons from pair production of 6.13 MeV ϒ-rays from the 19F(p,αϒ) 16O reaction. Two HPGe detectors facing opposite sides of the Ge crystal acting as target provided both coincidence and singles spectra. Changes in the shape of the annihilation peak were observed when the high voltage applied to the target detector was switched on or off, amounting to somewhat less than 20% when the areas of equivalent energy intervals in the corresponding normalized spectra are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se estudió el papel de la longitud de onda de la luz (color) en el grado de actividad motriz de tres especies de pepino de mar (Holothuria sanctori, H. dakarensis y H. arguinensis). Con independencia del tamaño de los individuos, H. sanctori prefiere los ambientes oscuros, permaneciendo inactiva en zonas iluminadas con independencia del color de la luz. H. dakarensis muestra actividad bajo luz roja, y H. arguinensis prefiere ambientes oscuros pero su desplazamiento es mayor en presencia de luz azul. ABSTRACT: The effect of the light wave length on the degree of activity of three species of sea cucumbers (Holothuria sanctori, H. dakarensis and H. arguinensis) was studied. Regardless of individuals sizes, H. sanctori prefered dark environments; this species remained inactive in illuminated areas regardless of the light colour. H. dakarensis showed activity under red light and H. arguinensis preferred dark environments, though its displacement was larger under blue light.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES] Los cárabos se caracterizan por tener sus mayores niveles de actividad durante la noche. Al ser sometidos a distintas longitudes de onda de luz, estos muestran un fototropismo negativo al ser expuestos bajo luces de color índigo, azul y naranja, y muy negativo bajo a la luz verde. Bajo luz roja su actividad es alta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES] El Detector de Efectos Stroop (SED - Stroop Effect Detector), es una herramienta informática de asistencia, desarrollada a través del programa de investigación de Desarrollo Tecnológico Social de la Universidad de Las Palmas de Gran Canaria, que ayuda a profesionales del sector neuropsicológico a identificar problemas en la corteza orbitofrontal de un individuo, usándose para ello la técnica ideada por Schenker en 1998. Como base metodológica, se han utilizado los conocimientos adquiridos en las diferentes materias de la adaptación al grado en Ingeniería Informática como Gestión del Software, Arquitectura del Software y Desarrollo de Interfaces de Usuario así como conocimiento adquirido con anterioridad en asignaturas de Programación e Ingeniería del Software I y II. Como para realizar este proyecto sólo el conocimiento informático no era suficiente, he realizado una labor de investigación acerca del problema, teniendo que recopilar información de otros documentos científicos que abordan el tema, consultas a profesionales del sector como son el Doctor Don Ayoze Nauzet González Hernández, neurólogo del hospital Doctor Negrín de Las Palmas de Gran Canaria y el psicólogo Don José Manuel Rodríguez Pellejero que habló de este problema en clase del máster de Formación del Profesorado y que actualmente estoy cursando. Este trabajo presenta el test de Stroop con las dos versiones de Schenker: RCN (Reading Color Names) y NCW (Naming Colored Words). Como norma general, ambas pruebas presentan ante los sujetos estudios palabras (nombres de colores) escritas con la tinta de colores diferentes. De esta forma, el RCN consiste en leer la palabra escrita omitiendo la tonalidad de su fuente e intentando que no nos influya. Por el contrario, el NCW requiere enunciar el nombre del color de la tinta con la que está escrita la palabra sin que nos influya que ésta última sea el nombre de un color.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] The aortic dissection is a disease that can cause a deadly situation, even with a correct treatment. It consists in a rupture of a layer of the aortic artery wall, causing a blood flow inside this rupture, called dissection. The aim of this paper is to contribute to its diagnosis, detecting the dissection edges inside the aorta. A subpixel accuracy edge detector based on the hypothesis of partial volume effect is used, where the intensity of an edge pixel is the sum of the contribution of each color weighted by its relative area inside the pixel. The method uses a floating window centred on the edge pixel and computes the edge features. The accuracy of our method is evaluated on synthetic images of different hickness and noise levels, obtaining an edge detection with a maximal mean error lower than 16 percent of a pixel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Máster Universitario en Sistemas Inteligentes y Aplicaciones Numéricas en Ingeniería (SIANI)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Máster Universitario en Sistemas Inteligentes y Aplicaciones Numéricas en Ingeniería (SIANI)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Programa de doctorado: Ingeniería de Telecomunicación Avanzada