912 resultados para EXTERNAL IRRADIATION
Resumo:
A broadly tunable and high-power grating-coupled external cavity laser with a tuning range of more than 200 nm and a similar to 200-mW maximum output power was realized, by utilizing a gain device with the chirped multiple quantum-dot (QD) active layers and bent waveguide structure. The chirped QD active medium, which consists of QD layers with InGaAs strain-reducing layers different in thickness, is beneficial to the broadening of the material gain spectrum. The bent waveguide structure and facet antireflection coating are both effective for the suppression of inner-cavity lasing under large injection current.
Resumo:
We present a novel system design that can generate the optimized wavelength-tunable optical pulse streams from an uncooled gain-switched Fabry-Perot semiconductor laser using an optical amplifier as external light source. The timing jitter of gain-switched laser has been reduced from about 3 ps to 600 fs and the pulse width has been optimized by using our system. The stability of the system was also experimentally investigated. Our results show that an uncooled gain-switched FP laser system can feasibly produce the stable optical pulse trains with pulse width of 18 ps at the repetition frequency of 5 GHz during 7 h continuous working. We respectively proved the system feasibility under 1 GHz, 2.5 GHz and 5 GHz operation. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Photonic crystals (PC) have received extensive attention for the photonic band gap (PBG). The polystyrene (PS) particles bottom-up approach is a productive method for photonic crystal manufacture, this kind of photonic crystals having an unique PBG that depends on the particle's shape, sizes and defects. Heavy ion irradiation is a very useful method to induce defects in PC and change the shapes of the particles to tune the PBG. MeV heavy ion irradiation leads to an anisotropic deformation of the particles from spherical to ellipsoidal, the aspect ratio of which can be precisely controlled by using the ion energy and flux. Sub-micrometer PS particles were deposited on a Cu substrate and were irradiated at 230 K by using heavy ion energy and fluence in the range from 2 to 10 MeV and 1 x 10(14) cm(-2) to 1 x 10(15) cm(-2); respectively.
Resumo:
Photonic crystals (PC) have received extensive attention for the photonic band gap (PBG). The polystyrene (PS) particles bottom-up approach is a productive method for photonic crystal manufacture, this kind of photonic crystals having an unique PBG that depends on the particle's shape, sizes and defects. Heavy ion irradiation is a very useful method to induce defects in PC and change the shapes of the particles to tune the PBG. MeV heavy ion irradiation leads to an anisotropic deformation of the particles from spherical to ellipsoidal, the aspect ratio of which can be precisely controlled by using the ion energy and flux. Sub-micrometer PS particles were deposited on a Cu substrate and were irradiated at 230 K by using heavy ion energy and fluence in the range from 2 to 10 MeV and 1 x 10(14) cm(-2) to 1 x 10(15) cm(-2); respectively.
Resumo:
单宁是一种典型的有毒难降解污染物,在制革、造纸、制药、印染等行业废水中广泛存在,对水环境造成污染并且影响废水生物处理效果。本研究针对含单宁废水生物处理效率低、较高浓度时微生物受抑制且污泥容易膨胀等问题,采用超声和磁粉来强化含单宁废水生物处理,研究超声和磁粉对微生物活性、污染物去除及污泥沉降性能的影响,并对其作用机理进行了分析和探讨。 研究结果表明,活性污泥系统中单宁酸容积负荷可以达到1.8kgCOD/(m3·d),单宁酸和COD去除率分别达到85.2%和79.6%,但如果负荷进一步增大则微生物活性迅速降低。系统在pH 5~8、温度20~35℃、DO>1 mg/L的条件下具有较好的单宁酸降解效果和处理稳定性。单宁降解动力学参数为:μmax =0.208h-1;Ks=226mg/L;Ki=522mg/L;kd=0.0092h-1;Y =0.594。 磁粉对系统处理效果和污泥沉降性能有一定的促进作用,且效果要优于外磁场。适宜的磁粉粒径和投加量分别为0.05~0.15mm和1.0g/L,COD去除率比对照系统提高6.4%,SVI降低28.6%,污泥絮体结构紧密。磁粉强化主要是通过其对污泥菌胶团的凝聚、吸附作用以及对微生物活性的强化作用实现。 在适当强度(0.4W/cm2)和辐照时间(20min)的超声作用下污泥絮体和细胞膜通透性增大,酶分泌也增多,系统的COD去除率比对照提高了8.8%,单宁酶酶活提高了11%。但超声也使污泥絮体结构松散,沉降性能下降,SVI比对照系统升高9.3%。 由于污泥流失加剧导致污泥浓度相对较低,声磁联合强化系统相对于磁粉强化系统其处理效果并没有提高。但相对于单纯活性污泥系统,声磁联合作用下系统处理效果、污泥沉降性能以及系统运行稳定性都得到明显改善。本研究为难降解废水的生物处理提供了一个新的思路。 Tannins are typical refractory and toxic pollutants that commonly exist in wastewater from dye, medicine, paper and leather industries and cause many problems associated with environmental pollution and biological treatment of wastewater. Biological treatment efficiency of tannin-containing wastewater is usually low owing to its biological toxicity and low biodegradability, microbes are usually inhibited under high tannin concentration and sludge bulking frequently occurs. In this study, ultrasound and magnetic powder were used to improve the biological treatment performance of simulated tannic acid-containing wastewater. The effects of ultrasonic irradiation and magnetic powder on microbial activity, tannic acid degradation rate and sludge sedimentation were investigated. The augmentation mechanisms were analyzed and discussed. The experimental results showed that the microbes were prominently inhibited under high tannic acid concentration, but moderate degradation efficiency can be maintained under a tannic acid load of up to 1.8kgCOD/(m3·d), with the tannic acid degradation and COD removal percentage of 85.2% and 79.6% respectively. The highest degradation rates and treatment stability were achieved at pH range of 5~8, temperature range of 20~35℃ and DO concentration of above 1mg/L. The kinetic parameters were estimated, including: μmax =0.208h-1;Ks=226mg/L;Ki=522mg/L;kd=0.0092h-1;Y =0.594. The microbial activity, tannic acid degradation rate and sludge sedimentation were improved by adding Fe3O4 magnetic powder, and the augmentation performance was better than external magnetic field. The appropriate particle size and dosage of magnetic powder were found to be 0.05~0.15mm and 1.0g/L, respectively, under which the COD removal percentage was improved by 6.4% and SVI value decreased by 28.6%, and compact floc structure was observed. This was mainly caused by the flocculation and adsorption effects of magnetic powder against sludge floc and the stimulation of microbial activity under appropriate magnetic field. Under appropriate ultrasonic irradiation (ultrasonic intensity 0.4W/cm2, ultrasonic irradiation time 20min), the permeability of floc and cell membrane are improved, transfer of substrate and oxygen were reinforced; meanwhile, more enzyme were produced by microbes under the slight damage caused by ultrasound. However, the floc structure became loose under ultrasonic irradiation, leading to relatively poor sedimentation, with the SVI value 9.3% higher than the control system. Although the magnetic powder-ultrasonic irradiation combined augmentation system showed no improvement in treatment performance compared with sole magnetic augmentation system owing to its relatively low sludge concentration, it guaranteed the stable operation of system, meanwhile the tannic acid degradation and sludge sedimentation were significantly improved compared with sole activated sludge system. This study gives a new idea for biological treatment of refractory wastewater.
Resumo:
Irradiation efect in three carbon allotropes C60, diamond and highly oriented pyrolytic graphite (HOPG) induced by 170 keV B ions, mainly including the process of the damage creation, is investigated by means of Raman spectroscopy technique. The diferences on irradiation sensitivity and structural stability for C60, HOPG and diamond are compared. The analysis results indicate that C60 is the most sensitive for B ions irradiation,diamond is the second one and the structure of HOPG is the most stable under B ion irradiation. The damage cross sections ? of C60, diamond and HOPG deduced from the Raman spectra are 7.78×10−15 , 6.38×10−15 and1.31 × 10−15cm2, respectively.
Resumo:
Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator af...
Resumo:
To determine whether adenovirus-mediated wild-type p53 transfer after radiotherapy could radiosensitize non-small-cell lung cancer (NSCLC) cells to subclinical-dose carbon-ion beam (C-beam), H1299 cells were exposed to a C-beam or -ray and then infected with 5 MOI of AdCMV-p53 or GFP (C-beam or -ray with p53 or GFP).Cell cycle was detected by flow cytometric analysis. The apoptosis was examined by a fluorescent microscope with DAPI staining. DNA fragmentation was monitored by the TUNEL assay. P53 mRNA was detected by reverse-transcriptase polymerase chain reaction. The expression of p53, MDM2, and p21 was monitored by Western blot. Survival fractions were determined by colony-forming assay. The percentages of G1-phase cells in C-beam with p53 increased by 8.2%–16.0%, 5.2%–7.0%, and 5.8%–18.9%, respectively, compared with C-beam only, -ray with p53, or p53 only. The accumulation of G2-phase cells in C-beam with p53 increased by 5.7%–8.9% and 8.8%–14.8%, compared with those in -ray with p53 or p53 only, respectively. The percentage of apoptosis for C-beam with p53 increased by 7.4%–19.1%, 5.8%–11.7%, and 5.2%–19.2%, respectively, compared with C-beam only, -ray with p53, or p53 only. The level of p53 mRNA in C-beam with p53 was significantly higher than that in p53 only. The expression level of p53 and p21 in C-beam with p53 was significantly higher than that in both C-beam with GFP and p53 only. The survival fractions for C-beam with p53 were significantly less than those for the other groups (p 0.05). The data suggested that AdCMV-p53 transfer could more efficiently radiosensitize H1299 cells to subclinical-dose C-beam irradiation through the restoration of p53 function.
Resumo:
A high energy heavy ion microbeam irradiation system is constructed at the Institute of Modern Physics (IMP) of the Chinese Academy of Sciences (CAS). A quadrupole focusing system, in combination with a series of slits, has been designed here. The IMP microbeam system is described in detail. The intrinsic and parasitic aberrations associated with the magnets are simulated. The ion beam optics of this microbeam system is investigated systematically. Then the optimized initial beam parameters are given for high spatial resolution and high hitting rates.
Resumo:
Abstract A state-of-the-art high energy heavy ion microbeam irradiation system is constructed at the Institute of Modern Physics of the Chinese Academy of Sciences. This microbeam system operates in both full current intensity mode and single ion mode. It delivers a predefined number of ions to preselected targets for research in biology and material science. The characteristic of this microbeam system is high energy and vertical irradiation. A quadrupole focusing system, in combination with a series of slits, has been designed to optimize the spatial resolution. A symmetrically achromatic system leads the beam downwards and serves simultaneously as an energy analyzer. A high gradient quadrupole triplet finally focuses a C6+ ion beam to 1 µm in the vacuum chamber within the energy range from 10 MeV/u to 100 MeV/u. In this paper, the IMP microbeam system is described in detail. A systematic investigation of the ion beam optics of this microbeam system is presented together with the associated aberrations. Comparison is made between the IMP microbeam system and the other existing systems to further discuss the performance of this microbeam. Then the optimized initial beam parameters are given for high resolution and high hitting efficiency. At last, the experiment platform is briefly introduced.