922 resultados para planar antennas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of high-impedance surfaces (HISs) to increase the frequency-scanning sensitivity of hollow leaky-wave antennas (LWAs) is presented. The LWA consists of a hollow rectangular waveguide with one of its narrow walls replaced by a partially reflective surface, and it is loaded with a metallodielectric HIS to increase its beam-scanning response. Theoretical results based on a simple transverse equivalent network illustrate the physical mechanism responsible for the improvement, and they are verified by experiments on a prototype working in the 11-16 GHz band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional reconstruction from volumetric medical images (e.g. CT, MRI) is a well-established technology used in patient-specific modelling. However, there are many cases where only 2D (planar) images may be available, e.g. if radiation dose must be limited or if retrospective data is being used from periods when 3D data was not available. This study aims to address such cases by proposing an automated method to create 3D surface models from planar radiographs. The method consists of (i) contour extraction from the radiograph using an Active Contour (Snake) algorithm, (ii) selection of a closest matching 3D model from a library of generic models, and (iii) warping the selected generic model to improve correlation with the extracted contour.

This method proved to be fully automated, rapid and robust on a given set of radiographs. Measured mean surface distance error values were low when comparing models reconstructed from matching pairs of CT scans and planar X-rays (2.57–3.74 mm) and within ranges of similar studies. Benefits of the method are that it requires a single radiographic image to perform the surface reconstruction task and it is fully automated. Mechanical simulations of loaded bone with different levels of reconstruction accuracy showed that an error in predicted strain fields grows proportionally to the error level in geometric precision. In conclusion, models generated by the proposed technique are deemed acceptable to perform realistic patient-specific simulations when 3D data sources are unavailable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crystallisation of the square-planar complex trans-Pt{PPh2(C16H15)}(2)Cl-2 from dichloromethane-diethyl ether (1:1) affords two different solvates; trans-Pt{PPh2(C16H15)}(2)Cl-2. CH2Cl2 1 and trans-Pt{PPh2(C16H15)}(2)Cl-2. Et2O 2; the CH2Cl2 forms H-bonding interactions with the complex whereas the Et2O participates only in weak van der Waals interactions; these differences arise from the different hydrogen-bonding characteristics of each solvent.