929 resultados para PHASE MORPHOLOGY ANALYSIS


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The intestinal epithelial cells of ticks are fundamental for their full feeding and reproductive success, besides being considered important sites for the development of pathogens. Rhipicephalus sanguineus ticks are known for their great medical and veterinary importance, and for this reason, the knowledge of their intestinal morphology may provide relevant subsidies for the control of these animals, either by direct acaricidal action over these cells or by the production of vaccines. Therefore, this study aimed to describe the midgut morphology of male and female R. sanguineus ticks in different feeding stages, by means of histological analysis. Significant differences were observed between the genders, and such alterations may refer mainly to the distinct demands for nutrients, much higher in females, which need to develop and carry out the egg-laying process. In general, the midgut is coated by a thin muscle layer and presents a pseudostratified epithelium, in which two basic types of cells can be observed, connected to a basal membrane - generative or stem and digestive cells. The latter was classified as follows: residual, deriving from the phase anterior to ecdysis; pinocytic, with vesicles containing liquid or pre-digested components of blood; phagocytic, with entire cells or remnants of nuclear material inside cytoplasmic vesicles; and mature, free in the lumen. Digestion is presumably intracellular and asynchronous and corresponds to a process which starts with the differentiation of generative cells into pinocytic digestive cells, which subsequently start to phagocytize intact blood cells and finally detach from the epithelium, being eliminated with feces. © 2012 Springer-Verlag Berlin Heidelberg.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Plasma electrolytic oxidation (PEO) is a coating procedure that utilises anodic oxidation in aqueous electrolytes above the dielectric breakdown voltage to produce oxide coatings that have specific properties. These conditions facilitate oxide formation under localised high temperatures and pressures that originate from short-lived microdischarges at sites over the metal surface and have fast oxide volume expansion. Anodic ZrO2 films were prepared by subjecting metallic zirconium to PEO in acid solutions (H2C 2O4 and H3PO4) using a galvanostatic DC regime. The ZrO2 microstructure was investigated in films that were prepared at different charge densities. During the anodic breakdown, an important change in the amplitude of the voltage oscillations at a specific charge density was observed (i.e., the transition charge density (Q T)). We verified that this transition charge is a monotonic function of both the current density and temperature applied during the anodisation, which indicated that Q T is an intrinsic response of this system. The oxide morphology and microstructure were characterised using SEM and X-ray diffraction experiments (XRD) techniques. X-ray diffraction analysis revealed that the change in voltage oscillation was correlated with oxide microstructure changes during the breakdown process. © 2012 Springer-Verlag Berlin Heidelberg.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Gas chromatography with mass spectrometry is frequently used for the quantification of many classes of substances, including alkylphenols. Alkylphenol polyethoxylates are nonionic surfactants used in a wide variety of industrial and consumer applications. Alkylphenol polyethoxylates can degrade to alkylphenols, which are endocrine disruptors. In analytical validation procedures, the most common parameters studied are the detection and quantification limits, linearity, and recovery; however, the matrix effects are sometimes neglected. Although some investigators have evaluated matrix effects, there is no consensus on how to evaluate them during method validation. In this study, the matrix effects of alkylphenol polyethoxylates (nonylphenol monoethoxylate, nonylphenol diethoxylate, octylphenol monoethoxylate, octylphenol diethoxylate) and alkylphenols (nonylphenol and octylphenol) were studied using solid phase extraction and gas chromatography-mass spectrometry analysis. For alkylphenol polyethoxylates, the matrix effects ranged from 16 to 4692%, whereas for alkylphenols (nonylphenol and octylphenol), the effects were insignificant. Therefore, constructing an analytical curve in the matrix for alkylphenol polyethoxylates is essential. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACT: The present work uses multivariate statistical analysis as a form of establishing the main sources of error in the Quantitative Phase Analysis (QPA) using the Rietveld method. The quantitative determination of crystalline phases using x ray powder diffraction is a complex measurement process whose results are influenced by several factors. Ternary mixtures of Al2O3, MgO and NiO were prepared under controlled conditions and the diffractions were obtained using the Bragg-Brentano geometric arrangement. It was possible to establish four sources of critical variations: the experimental absorption and the scale factor of NiO, which is the phase with the greatest linear absorption coefficient of the ternary mixture; the instrumental characteristics represented by mechanical errors of the goniometer and sample displacement; the other two phases (Al2O3 and MgO); and the temperature and relative humidity of the air in the laboratory. The error sources excessively impair the QPA with the Rietveld method. Therefore it becomes necessary to control them during the measurement procedure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of breed and season on semen quality parameters of zebu bulls. Data (1,632 registers) of semen production from Gir (n = 4) and Nelore (n = 15) bulls were collected between October 2005 and November 2009. The ejaculates were collected twice a week during various seasons (summer, fall, winter, and spring) and evaluated for the following semen parameters: ejaculate volume, sperm concentration, sperm motility, forward progressive motility (FPM), and sperm morphology. Factor analysis was used to determine the relationship among variables. The effect of breed (Gir and Nelore) and season and their cross effect on each parameter and extracted factor were tested using ANOVA. A negative correlation (P < 0.05) was observed between FPM and proximal droplet, as well as with abnormal loose head, abnormal small head, pouch formation, abnormal mid-peace, and strongly folded tail. Gir bull sperm showed more major defects, detached acrosome, and minor FPM (P < 0.01), whereas Nelore bulls showed a higher number of sperm with normally loose head.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Direct immersion SPME-GC-MS-MS was used for the analysis of steroids in water at part-per-trillion(ppt) and lower concentrations. The method was validated and extended to real sample analysis. The method were linear from 0.01 to 5 ng/ml with precision less than 10% relative standard deviation for a steroid mixture at 1 ng/ml. Limit of quantitation and limit of detection was found to be 200- 1200 pg/L and 30-200 pg/L respectively and recoveries ranged from 88-103 %. To understand the extraction efficiency of the fiber, a depletion study was performed. The fiber/ sample partition coefficients for the steroids were determined to be 1.0 x 104 to 1.5 x 104 . The extraction was performed without derivatization or the use of an internal standard. SPMEGC-MS-MS effectively demonstrated ultra-trace level detection of steroids in water.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work we present a Raman study of PbZr1-xTi xO3 ceramics with composition values close to the morphotropic phase boundary region. The analysis of the Raman spectra leads to the determination of the monoclinic phase extension at different temperatures in a very good agreement with those determined by diffraction techniques. Therefore the obtained results show that Raman spectroscopy is a powerful and suitable technique to study structural phase transitions in PbZr 1-xTixO3. © 2002 Taylor & Francis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Most advanced eusocial bees recruit their nestmates to food resources. Recently, studies in Meliponini species showed that the cephalic salivary (labial) glands (CSGs) are responsible for the production of scent-trail pheromones. Studies on CSGs have shown changes in glandular cell morphology since the worker emerges from brood combs (newly emerged) till forager phase, which may be correlated to changes in the composition of secretion produced. However, no study has been made till now regarding to the composition of CSGs secretion of Scaptotrigona postica and the chemical changes that occur in this secretion according to the worker's life phase or tasks performed. In this study, the chemical profile of CSG secretion in S. postica workers was studied. Glands were taken from specimens newly emerged (NE), working in the brood combs area (CA) and forager (FO) and were analyzed by gas chromatography-mass spectrometry. The results showed that glandular secretion consists of oxygenated compounds of middle volatility (acids, alcohols, aldehydes, ketones, esters and ether), and their quantity varies among the different phases of life, increasing as the individual undergoes from intra- to extra-colonial activities. The NE phase contained the smallest variety and quantity of compounds. Due to the variability of compounds, the CA workers were separated into 3 groups according to the chemical constitution of their secretion. Forager workers showed the largest quantity and variety of chemical compounds. The major compounds in forager gland secretion are 7-hexadecen-1-yl acetate and 5-tetradecen-1-yl acetate. Statistical analysis indicates that the chemical composition of glandular secretion is task-related.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Morphology and deformation mechanisms and tensile properties of tetrafunctional multigraft (MG) polystrene-g-polyisoprene (PS-g-PI) copolymers were investigated dependent on PS volume fraction and number of branch points. The combination of various methods such as TEM, real time synchrotron SAXS, rheo-optical FTIR, and tensile tests provides comprehensive information at different dimension levels.TEMand SAXS studies revealed that the number of branch points has no obvious influence on the microphase-separated morphology of tetrafunction MG copolymers with 16 wt % PS. But for tetrafunctional MG copolymers with 25 wt % PS, the size and integrity of PS microdomains decrease with increasing number of branch point. The deformation mechanisms ofMGcopolymers are highly related to the morphology. Dependent on the microphase-separated morphology and integrity of the PS phase, the strain-induced orientation of the PS phase is at different size scales. Polarized FT-IR spectra analysis reveals that, for all investigated MG copolymers, the PI phase shows strain-induced orientation along SD at molecular scale. The proportion of the PI block effectively bridging PS domains controls the tensile properties of the MGcopolymers at high strain, while the stress-strain behavior in the low-mediate strain region is controlled by the continuity of PS microdomains. The special molecular architecture, which leads to the higher effective functionality of PS domains and the higher possibility for an individual PI backbone being tethered with a large number of PS domains, is proposed to be the origin of the superelasticity for MG copolymers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL(-1) (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT. PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.