867 resultados para Coated fertilizer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate animal performance and carcass characteristics of 64 Nellore young bulls at 22 months of age finished in a feedlot and slaughtered at five body weights (350; 455; 485; 555 and 580 kg) fed diets containing coated or uncoated urea. The experimental design adopted was completely randomized, set in a 4 × 2 factorial arrangement, and for the variables assessed in the control animals, it was 5 × 2. No effect of interaction between slaughter weights and diets were observed, so the variables were analyzed separately, compared by polynomial contrasts and by the F test, respectively. The time animals remained in the feedlot to reach slaughter weights was 66, 88, 145 and 194 days. Average daily gain (ADG) showed quadratic behavior, with a maximum of 1.44 kg/day with animals of 491.7 kg. Dry matter intake (DMI) (kg/day) was similar in all the treatments, but it decreased linearly as body weight increased. The bionutritional efficiency worsened linearly as body weight rose. The elevation in slaughter weight resulted in linear decrease in the percentage of beef round and increase in forequarter. Backfat thickness and rib eye area of the longissimus increased linearly and the percentages of muscle and protein in the carcass reduced and those of fat and ether extract increased linearly as body weight increased. Average daily gain, DMI, feed efficiency and carcass characteristics were not affected by diets containing coated or uncoated urea. However, animals fed coated urea presenter better crude fiber and neutral detergent fiber intake.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Algumas culturas têm pouca adaptação ao sistema plantio direto (SPD), em vista da alta compactação da camada superficial do solo. Nesse caso, o mecanismo utilizado na semeadora para a abertura dos sulcos para deposição do fertilizante pode ter grande importância no sentido de facilitar a penetração das raízes. Avaliouse a influência do mecanismo de distribuição de fertilizante e da adubação nitrogenada na cultura do arroz de terras altas (Oryza sativa) no sistema plantio direto. O experimento foi conduzido nos anos agrícolas 2001/2002 e 2002/2003, em Botucatu-SP, Brasil. O delineamento experimental foi em blocos casualizados, com parcelas subdivididas e quatro repetições. As parcelas foram constituídas por dois mecanismos de distribuição de fertilizantes (haste sulcadora e disco duplo). Nas subparcelas, quatro níveis de N foram aplicados em cobertura (0, 40, 80 e 120 kg ha-1). Avaliou-se a profundidade de abertura do sulco e de deposição das sementes, a população de plantas, a altura de plantas, o número de colmos e de panículas m-2, o número total de espiguetas por panícula, a fertilidade das espiguetas, a massa de 1.000 grãos, a matéria seca da parte aérea, a produtividade e o teor de N na folha bandeira. O sucesso no estabelecimento da cultura do arroz de terras altas no SPD nas regiões de inverno seco do Brasil está diretamente ligado ao mecanismo de distribuição das semeadoras-adubadoras. A haste sulcadora promoveu maior profundidade de deposição de sementes, conseqüentemente reduzindo o estande, o número de panículas por área e a produtividade. A aplicação de N em cobertura no arroz de terras altas em SPD proporciona maiores produtividades quando a semeadura é realizada com mecanismo de disco duplo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os ensaios de largura de trabalho e uniformidade de distribuição são de difícil execução para o agricultor por exigirem equipamentos, recursos e métodos complexos. Portanto, este trabalho teve como objetivo avaliar coletores alternativos para tornar mais acessível a regulagem e a avaliação de distribuidores de fertilizantes sólidos a lanço. Foram utilizados quatro diferentes conjuntos de coletores: i) coletores construídos segundo a norma ISO 5690/1; ii) coletores de polietileno (bandejas plásticas) com tela de sombreamento para evitar o ricochete de material; iii) coletores formados por caixas de leite longa vida, e iv) coletores formados por vasos de polietileno (número 3,5). Também foram utilizados três diferentes distribuidores para as avaliações. Os coletores alternativos apresentaram maior retenção de partículas que os coletores normatizados. A largura efetiva de trabalho obtida para os coeficientes de variação de 12,5; 15; 17,5 e 20% variou entre os coletores nos diferentes percursos. O coletor que mais se assemelhou à norma foram os vasos de polietileno. Constatou-se que a altura dos coletores foi mais importante para sua eficiência do que a sua área de coleta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of a microbiological assay, applying cylinder plate method for determination of the activity of lomefloxacin in coated tablets is described. Using a strain of Bacillus subtilis ATCC 9372 as the test organism, lomefloxacin was measured in concentrations ranging from 2.0 to 8.0 mu g/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation 1.15%), and accurate (it measured the added quantities). The excipients did not interfere in the determination. It was concluded that the microbiological assay is satisfactory for quantitation of lomefloxacin in tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fatigue, corrosion and wear resistance are important parameters in aircraft components development as landing gear. High strength/weight ratio and effective corrosion resistance make of titanium alloys an alternative choice to replace steel and aluminum alloys. However, titanium alloys have poor tribological properties, which reduce devices performance under friction. PVD coatings tribological systems has been increased due to their attractive mechanical properties as low environmental impact, low friction coefficient, low wear rate and hardness up to 2000 HV.In this study the influence of TiN deposited by PVD on the fatigue strength of Ti-6Al-4V alloy was evaluated. Comparison of fatigue strength of coated specimens and base material shows also a decrease when parts are coated. It was observed that the influence is more significant in high cycle fatigue tests. Scanning electron microscopy technique (SEM) was used to observe crack origin sites and fracture features. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral administration is a common route in the drug therapy and the solid pharmaceutical forms are widely used. Although much about the performance of these formulations can be learned from in vitro studies using conventional methods, evaluation in vivo is essential in product development. The knowledge of the gastrointestinal transit and how the physiological variables can interfere with the disintegration and drug absorption is a prerequisite for development of dosage forms. The aim of this work was to employing the ac biosusceptometry (ACB) to monitoring magnetic tablets in the human gastrointestinal tract and to obtain the magnetic images of the disintegration process in the colonic region. The ac biosusceptometry showed accuracy in the quantification of the gastric residence time, the intestinal transit time and the disintegration time (DT) of the magnetic formulations in the human gastrointestinal tract. Moreover, ac biosusceptometry is a non-invasive technique, radiation-free and harmless to the volunteers, as well as an important research tool in the pharmaceutical, pharmacological and physiological investigations. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To employ the AC Biosusceptometry (ACB) technique to evaluate in vitro and in vivo characteristics of enteric coated magnetic hydroxypropyl methylcellulose (HPMC) capsules and to image the disintegration process.Materials and Methods. HPMC capsules filled with ferrite (MnFe2O4) and coated with Eudragit (R) were evaluated using USP XXII method and administered to fasted volunteers. Single and multisensor ACB systems were used to characterize the gastrointestinal (GI) motility and to determine gastric residence time (GRT), small intestinal transit time (SITT) and orocaecal transit time (OCTT). Mean disintegration time (t (50)) was quantified from 50% increase of pixels in the imaging area.Results. In vitro and in vivo performance of the magnetic HPMC capsules as well as the disintegration process were monitored using ACB systems. The mean disintegration time (t (50)) calculated for in vitro was 25 +/- 5 min and for in vivo was 13 +/- 5 min. In vivo also were determined mean values for GRT (55 +/- 19 min), SITT (185 +/- 82 min) and OCTT (240 +/- 88 min).Conclusions. AC Biosusceptometry is a non-invasive technique originally proposed to monitoring pharmaceutical dosage forms orally administered and to image the disintegration process.