Fault Current Limiter Using YBCO Coated Conductor-The Limiting Factor and Its Recovery Time
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
20/05/2014
20/05/2014
01/06/2009
|
Resumo |
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) A fault current limiter (FCL) based on an arrangement of parallel connected high temperature superconducting tapes constituting a limiter element was designed and tested in 220 V line for a fault current peak between 1 kA to 2 kA. The limiter employed second generation (2G) HTS tapes of YBCO coated conductor reinforced with stainless steel. Four tapes were electrically connected in parallel with 0.4 m effective length per element wherein 16 elements connected in series constitutes a single-phase unit. The FCL performance was evaluated through over-current and current fault tests. Its recovery characteristics were used to design the shunt protection. The designed limiting ratio is 4 for 16 elements and the experimental result for one element showed a 20% limiting ratio. For the fault current test one element can withstand five cycles of fault without degradation. It was observed recovery times below 0.5 s under nominal load using a shunt resistance of 173 m Omega. |
Formato |
1810-1813 |
Identificador |
http://dx.doi.org/10.1109/TASC.2009.2019043 IEEE Transactions on Applied Superconductivity. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 19, n. 3, p. 1810-1813, 2009. 1051-8223 http://hdl.handle.net/11449/9013 10.1109/TASC.2009.2019043 WOS:000268282100169 |
Idioma(s) |
eng |
Publicador |
Institute of Electrical and Electronics Engineers (IEEE) |
Relação |
IEEE Transactions on Applied Superconductivity |
Direitos |
closedAccess |
Palavras-Chave | #Current limiting ratio #superconducting fault current limiter #YBCO coated conductor #YBCO recovery characteristics |
Tipo |
info:eu-repo/semantics/article |