Microbiological assay for lomefloxacin in coated tablets
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
20/05/2014
20/05/2014
01/07/2006
|
Resumo |
The validation of a microbiological assay, applying cylinder plate method for determination of the activity of lomefloxacin in coated tablets is described. Using a strain of Bacillus subtilis ATCC 9372 as the test organism, lomefloxacin was measured in concentrations ranging from 2.0 to 8.0 mu g/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation 1.15%), and accurate (it measured the added quantities). The excipients did not interfere in the determination. It was concluded that the microbiological assay is satisfactory for quantitation of lomefloxacin in tablets. |
Formato |
1077-1079 |
Identificador |
http://www.ingentaconnect.com/content/aoac/jaoac/2006/00000089/00000004/art00024 Journal of Aoac International. Gaithersburg: Aoac International, v. 89, n. 4, p. 1077-1079, 2006. 1060-3271 http://hdl.handle.net/11449/7739 WOS:000239470600025 |
Idioma(s) |
eng |
Publicador |
Aoac International |
Relação |
Journal of AOAC International |
Direitos |
closedAccess |
Tipo |
info:eu-repo/semantics/article |