985 resultados para self-deployment algorithms
Resumo:
Multilayered heterostructures based on embedded a-Si:H and a-SiC:H p-i-n filters are analyzed from differential voltage design perspective using short- and long-pass filters. The transfer functions characteristics are presented. A numerical simulation is presented to explain the filtering properties of the photonic devices. Several monochromatic pulsed lights, separately (input channels) or in a polychromatic mixture (multiplexed signal) at different bit rates, illuminated the device. Steady-state optical bias is superimposed from the front and the back side. Results show that depending on the wavelength of the external background and impinging side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. Particular attention is given to the amplification coefficient weights, which allow to take into account the wavelength background effects when a band or frequency needs to be filtered or the gate switch, in which optical active filter gates are used to select and filter input signals to specific output ports in wavelength division multiplexing (WDM) communication systems. This nonlinearity provides the possibility for selective removal or addition of wavelengths. A truth table of an encoder that performs 8-to-1 MUX function exemplifies the optoelectronic conversion.
Resumo:
Dissertação de Mestrado em Ciências Económicas e Empresariais
Resumo:
This work aims at investigating the impact of treating breast cancer using different radiation therapy (RT) techniques – forwardly-planned intensity-modulated, f-IMRT, inversely-planned IMRT and dynamic conformal arc (DCART) RT – and their effects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB treatment planning system were compared: Pencil Beam Convolution (PBC) and commercial Monte Carlo (iMC). Seven left-sided breast patients submitted to breast-conserving surgery were enrolled in the study. For each patient, four RT techniques – f-IMRT, IMRT using 2-fields and 5-fields (IMRT2 and IMRT5, respectively) and DCART – were applied. The dose distributions in the planned target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose–volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all techniques provided adequate coverage of the PTV. However, statistically significant dose differences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung and heart than tangential techniques. However, IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Differences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the iMC algorithm predicted.
Resumo:
Introduction: Image resizing is a normal feature incorporated into the Nuclear Medicine digital imaging. Upsampling is done by manufacturers to adequately fit more the acquired images on the display screen and it is applied when there is a need to increase - or decrease - the total number of pixels. This paper pretends to compare the “hqnx” and the “nxSaI” magnification algorithms with two interpolation algorithms – “nearest neighbor” and “bicubic interpolation” – in the image upsampling operations. Material and Methods: Three distinct Nuclear Medicine images were enlarged 2 and 4 times with the different digital image resizing algorithms (nearest neighbor, bicubic interpolation nxSaI and hqnx). To evaluate the pixel’s changes between the different output images, 3D whole image plot profiles and surface plots were used as an addition to the visual approach in the 4x upsampled images. Results: In the 2x enlarged images the visual differences were not so noteworthy. Although, it was clearly noticed that bicubic interpolation presented the best results. In the 4x enlarged images the differences were significant, with the bicubic interpolated images presenting the best results. Hqnx resized images presented better quality than 4xSaI and nearest neighbor interpolated images, however, its intense “halo effect” affects greatly the definition and boundaries of the image contents. Conclusion: The hqnx and the nxSaI algorithms were designed for images with clear edges and so its use in Nuclear Medicine images is obviously inadequate. Bicubic interpolation seems, from the algorithms studied, the most suitable and its each day wider applications seem to show it, being assumed as a multi-image type efficient algorithm.
Resumo:
Introduction: A major focus of data mining process - especially machine learning researches - is to automatically learn to recognize complex patterns and help to take the adequate decisions strictly based on the acquired data. Since imaging techniques like MPI – Myocardial Perfusion Imaging on Nuclear Cardiology, can implicate a huge part of the daily workflow and generate gigabytes of data, there could be advantages on Computerized Analysis of data over Human Analysis: shorter time, homogeneity and consistency, automatic recording of analysis results, relatively inexpensive, etc.Objectives: The aim of this study relates with the evaluation of the efficacy of this methodology on the evaluation of MPI Stress studies and the process of decision taking concerning the continuation – or not – of the evaluation of each patient. It has been pursued has an objective to automatically classify a patient test in one of three groups: “Positive”, “Negative” and “Indeterminate”. “Positive” would directly follow to the Rest test part of the exam, the “Negative” would be directly exempted from continuation and only the “Indeterminate” group would deserve the clinician analysis, so allowing economy of clinician’s effort, increasing workflow fluidity at the technologist’s level and probably sparing time to patients. Methods: WEKA v3.6.2 open source software was used to make a comparative analysis of three WEKA algorithms (“OneR”, “J48” and “Naïve Bayes”) - on a retrospective study using the comparison with correspondent clinical results as reference, signed by nuclear cardiologist experts - on “SPECT Heart Dataset”, available on University of California – Irvine, at the Machine Learning Repository. For evaluation purposes, criteria as “Precision”, “Incorrectly Classified Instances” and “Receiver Operating Characteristics (ROC) Areas” were considered. Results: The interpretation of the data suggests that the Naïve Bayes algorithm has the best performance among the three previously selected algorithms. Conclusions: It is believed - and apparently supported by the findings - that machine learning algorithms could significantly assist, at an intermediary level, on the analysis of scintigraphic data obtained on MPI, namely after Stress acquisition, so eventually increasing efficiency of the entire system and potentially easing both roles of Technologists and Nuclear Cardiologists. In the actual continuation of this study, it is planned to use more patient information and significantly increase the population under study, in order to allow improving system accuracy.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Non-suicidal self-injury (NSSI) is the deliberate, self-inflicted destruction of body tissue without suicidal intent and an important clinical phenomenon. Rates of NSSI appear to be disproportionately high in adolescents and young adults, and is a risk factor for suicidal ideation and behavior. The present study reports the psychometric properties of the Impulse, Self-harm and Suicide Ideation Questionnaire for Adolescents (ISSIQ-A), a measure designed to comprehensively assess the impulsivity, NSSI behaviors and suicide ideation. An additional module of this questionnaire assesses the functions of NSSI. Results of Confirmatory Factor Analysis (CFA) of the scale on 1722 youths showed items' suitability and confirmed a model of four different dimensions (Impulse, Self-harm, Risk-behavior and Suicide ideation) with good fit and validity. Further analysis showed that youth׳s engagement in self-harm may exert two different functions: to create or alleviate emotional states, and to influence social relationships. Our findings contribute to research and assessment on non-suicidal self-injury, suggesting that the ISSIQ-A is a valid and reliable measure to assess impulse, self-harm and suicidal thoughts, in adolescence.
Resumo:
The process of immobilization of biological molecules is one of the most important steps in the construction of a biosensor. In the case of DNA, the way it exposes its bases can result in electrochemical signals to acceptable levels. The use of self-assembled monolayer that allows a connection to the gold thiol group and DNA binding to an aldehydic ligand resulted in the possibility of determining DNA hybridization. Immobilized single strand of DNA (ssDNA) from calf thymus pre-formed from alkanethiol film was formed by incubating a solution of 2-aminoethanothiol (Cys) followed by glutaraldehyde (Glu). Cyclic voltammetry (CV) was used to characterize the self-assembled monolayer on the gold electrode and, also, to study the immobilization of ssDNA probe and hybridization with the complementary sequence (target ssDNA). The ssDNA probe presents a well-defined oxidation peak at +0.158 V. When the hybridization occurs, this peak disappears which confirms the efficacy of the annealing and the DNA double helix performing without the presence of electroactive indicators. The use of SAM resulted in a stable immobilization of the ssDNA probe, enabling the hybridization detection without labels. This study represents a promising approach for molecular biosensor with sensible and reproducible results.
Resumo:
Agências financiadoras: FCT - PEstOE/FIS/UI0618/2011; PTDC/FIS/098254/2008 ERC-PATCHYCOLLOIDS e MIUR-PRIN
Resumo:
Drawing on postcolonial studies and the theorization on imperial gothic, this paper centres on three texts: The Hosts of the Lord (1900) by Flora Annie Steel; East of Suez (1901) by Alice Perrin, and The Way of an Eagle (1912)by Ethel Dell. These three texts highlight in different ways the discursive mediation of the Other and its destabilizing effects on the identity of the European-minded colonizer, thus foregrounding the multifarious nature of the British imaginative engagement with India. In this context, it is particularly relevant to examine the political and ideological implications of representing anywhere East of Suez as a locus of primitivism and chaos vis-à-vis the colonizer’s ambivalent reactions. Thus we seek to demonstrate the power of two distinct practices or modes of representation – namely, the power of a metaphorical discourse versus metonymic discourse- within the proces of constructing the East for a vast Western readership.
Resumo:
OBJECTIVE: To estimate the validity of three single questions used to assess self-reported hearing loss as compared to pure-tone audiometry in an adult population. METHODS: A validity study was performed with a random sub-sample of 188 subjects aged 30 to 65 years, drawn from the fourth wave of a population-based cohort study carried out in Salvador, Northeastern Brazil. Data were collected in household visits using questionnaires. Three questions were used to separately assess self-reported hearing loss: Q1, "Do you feel you have a hearing loss?"; Q2, "In general, would you say your hearing is 'excellent,' 'very good,' 'good,' 'fair,' 'poor'?"; Q3, "Currently, do you think you can hear 'the same as before', 'less than before only in the right ear', 'less than before only in the left ear', 'less than before in both ears'?". Measures of accuracy were estimated through seven measures including Youden index. Responses to each question were compared to the results of pure-tone audiometry to estimate accuracy measures. RESULTS: The estimated sensitivity and specificity were 79.6%, 77.4% for Q1; 66.9%, 85.1% for Q2; and 81.5%, 76.4% for Q3, respectively. The Youden index ranged from 51.9% (Q2) to 57.0% (Q1) and 57.9% (Q3). CONCLUSIONS: Each of all three questions provides responses accurate enough to support their use to assess self-reported hearing loss in epidemiological studies with adult populations when pure-tone audiometry is not feasible.
Resumo:
OBJECTIVE: To assess regional and sociodemographic differences in self-perceived health status among older adults. METHODS: A face-to-face quality of life survey was conducted in a representative sample of the Spanish population comprising 1,106 non-institutionalized elderly aged 60 or more in 2008. Logistic regression models were used to explain self-perceived health status according to the EuroQol Group Visual Analogue Scale (EQ-VAS). Independent variables included sociodemographic and health characteristics as well as the nomenclature of territorial units for statistics level 1 (NUTS1: group of autonomous regions) and level 2 (NUTS 2: autonomous regions). RESULTS: Younger and better off respondents were more likely to have a positive self-perceived health status. Having no chronic conditions, independence in performing daily living activities and lower level of depression were also associated with positive self-perceived health status. People living in the south of Spain showed a more negative self-perceived health status than those living in other regions. CONCLUSION: The study results point to health inequality among Spanish older adults of lower socioeconomic condition and living in the south of Spain. The analysis by geographic units allows for international cross-regional comparisons.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações