957 resultados para non-destructive test


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several one-dimensional design methods have been used to predict the off-design performance of three modern centrifugal compressors for automotive turbocharging. The three methods used are single-zone, two-zone, and a more recent statistical method. The predicted results from each method are compared against empirical data taken from standard hot gas stand tests for each turbocharger. Each of the automotive turbochargers considered in this study have notably different geometries and are of varying application. Due to the non-adiabatic test conditions, the empirical data has been corrected for the effect of heat transfer to ensure comparability with the 1D models. Each method is evaluated for usability and accuracy in both pressure ratio and efficiency prediction. The paper presents an insight into the limitations of each of these models when applied to one-dimensional automotive turbocharger design, and proposes that a corrected single-zone modelling approach has the greatest potential for further development, whilst the statistical method could be immediately introduced to a design process where design variations are limited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ∼2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transpiration of two year-old olive trees of three different varieties, Arbequina, Cobrançosa and Galega (18 trees per variety), irrigated with three levels of salt (0, 80 or 200 mM NaCl) for about 90 days, was measured by a gravimetric method. To determine leaf area, each tree was photographed from the side against a white background and the total area of each projected image was determined with ImageJ software. To calibrate these area determinations, one tree of each variety was subsequently stripped of all its leaves and its total leaf area was accurately measured. A correlation was then obtained between the area on the photograph of this particular tree and the total area of the detached leaves of the same tree. Using the leaf area determined by this procedure, transpiration rates of the trees could be calculated. Knowing leaf and air temperatures and RH, it was possible to determine the difference in molar fraction of water between the leaf and the air. Using this and the values of the transpiration rate, stomatal conductance could be calculated (gs calc) and compared with the conductance measured on the same trees with a porometer (gs). Actual leaf area of a plant was 1,40 (Arbequina), 1,42 (Cobrançosa) or 1,24 (Galega) times the area measured with ImageJ on the photograph of the same plant. Leaf area of the trees, on average of all salt irrigations, was significantly higher on Arbequina (0,187 m2) then on the other two varieties (0,138 m2 or 0,148 m2, for Cobrançosa or Galega, respectively), but did not differ significantly in percentage of controls (0 salt). On average of all three varieties, leaf area was also higher on plants irrigated without salt (0,181 m2) than on plants exposed to 80 or 200 mM NaCl (0,152 m2 or 0,140 m2, respectively), which did not differ between them. The same significant difference was observed when leaf area was expressed as percentage of controls. Transpiration rate was significantly higher on Cobrançosa (1,17 mmol m-2 s-1), on average of all treatments, but there were no significant differences between Arbequina (1,08 mmol m-2 s-1) and Galega (0,82 mmol m-2 s-1). In percentage of controls, there were no significant differences between varieties. Salt reduced significantly the transpiration rate in all varieties, both the actual and percentual values, to about 50% or 30% of controls when exposed to 80 mM or 200 mM NaCl, respectively. Stomatal conductance (gs), assessed by porometry, was significantly higher in control plants, mainly in Cobrançosa (102 mmol m-2 s-1), then in Arbequina (77 mmol m-2 s-1) and the lower values were found in Galega (51 mmol m-2 s-1). Salt reduced gs, on average of the three varieties to 30% or 10% of controls on exposure to 80 mM or 200 mM NaCl, respectively. Calculated (gs calc) and measured (gs) values of stomatal conductance showed a close relation between them (0,967, R2 = 0,837) which indicates this non-destructive method to determine whole-plant leaf area to be reasonably accurate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Os sistemas aquáticos naturais podem estar sujeitos frequentemente a entrada de tóxicos, quer seja através da lixiviação dos campos agrícolas ou da descarga por parte de unidades industriais. Avaliar o impacto potencial destes contaminantes nos sistemas aquáticos é muito importante, porque pode promover consequências sérias no balanço ecológico dos ecossistemas. Os efeitos de níveis sub-letais destes tóxicos nas populações aquáticas são detectados, em muitos casos, somente após diversas gerações, dependendo da espécie e do contaminante. O comportamento animal é considerado como sendo a primeira linha de defesa perante estímulos ambientais, e pode ser uma representação de alterações fisiológicas no organismo, sendo portanto um indicador excelente de alterações ambientais. O desenvolvimento dos sistemas de aviso prévio que integram parâmetros comportamentais pode ajudar a prever mais rapidamente possíveis alterações ao nível das populações naturais, do que a utilização de testes ecotoxicológicos padrão com a mesma finalidade. O conhecimento acerca de possíveis implicações devido a alterações comportamentais, em organismos bentónicos e em populações do campo sujeitas a tóxicos, é ainda escasso. Sabendo isto, neste estudo pretendeu-se investigar como o comportamento de Chironomus riparius – usando um biomonitor em tempo real – e outros parâmetros tais como crescimento, emergência de adultos, bioacumulação e biomarcadores, são afectados pela exposição a imidacloprid e ao mercúrio, que foram seleccionados como contaminantes. Os resultados demonstraram que a exposição às concentrações sub-letais de imidacloprid afecta o crescimento e o comportamento dos quironomídeos e que estes organismos podem recuperar de uma exposição curta ao insecticida. O comportamento que corresponde à ventilação de C. riparius revelou-se como um parâmetro mais sensível do que a locomoção e do que as respostas bioquímicas, quando as larvas foram sujeitas ao imidacloprid. Larvas de C. riparius expostas a concentrações sub-letais de mercúrio apresentaram uma tendência de diminuição de actividade comportamental, em testes com concentrações crescentes do tóxico; o crescimento das larvas foi também prejudicado, e as taxas de emergência de adultos e o tempo de desenvolvimento apresentaram retardamento. Estes organismos podem bioacumular rapidamente o mercúrio em condições de não alimentação e apresentam uma lenta depuração deste metal. Estes efeitos podem, em último caso, conduzir a prováveis repercussões ao nível da população e das comunidades. As reduções em actividades comportamentais, mesmo em concentrações baixas, podem diminuir a quantidade de tempo gasta na procura de alimento, produzindo efeitos aos níveis morfo-fisiológicos, e assim afectar severamente o desempenho dos quironomídeos no ambiente. O uso destes factores comportamentais como um parâmetro ecotoxicológico sub-letal relevante ao nível da toxicologia aumentará a versatilidade dos testes, permitindo uma resposta comportamental mensurável e quantitativa ao nível do organismo, utilizando uma avaliação não destrutiva, e assim certificando que esta aproximação pode ser usada em testes ecotoxicológicos futuros.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente trabalho centra-se no desenvolvimento e aplicação de sensores de aceleração ópticos, baseados em redes de Bragg gravadas em fibras ópticas, para monitorização da integridade estrutural de estruturas de engenharia civil. Foram implementados dois acelerómetros uniaxiais e um acelerómetro biaxial. Recorreu-se a uma ferramenta de simulação baseada no método dos elementos finitos que permitiu optimizar, sem custos de produção, as características dos sensores, nomeadamente a sua frequência de ressonância. A caracterização dos sensores foi realizada em ambiente laboratorial e a sua resposta comparada com os resultados de simulação, de modo a validar os modelos numéricos. A aplicabilidade e demonstração de conceito foram realizadas na monitorização de estruturas com testes de campo. Foi monitorizado um teste destrutivo de uma parede de adobe, construída à escala real no Departamento de Engenharia Civil da Universidade de Aveiro, onde foram utilizados sensores estáticos e dinâmicos baseados em redes de Bragg gravadas em fibra óptica. Foram realizadas medidas dinâmicas na ponte pedonal do Campus Universitário da Universidade de Aveiro, onde se compararam os resultados obtidos com os sensores ópticos com resultados de sensores electrónicos comerciais. O acelerómetro biaxial foi testado na monitorização de estruturas esbeltas, nomeadamente na monitorização de duas torres de telecomunicações móveis, onde se demonstrou a possibilidade da utilização de sensores ópticos na caracterização dinâmica deste tipo de estruturas. Outro tipo de estruturas de engenharia civil onde foi demonstrada a aplicabilidade dos sensores ópticos desenvolvidos na monitorização estrutural foram os reservatórios de água elevados. Foi realizada a monitorização dinâmica de um exemplo deste tipo de estruturas, localizado no Campus Universitário da Universidade de Aveiro. A monitorização foi realizada recorrendo ao sensor biaxial desenvolvido e a um sismógrafo, ficando o sensor óptico instalado na estrutura de modo a permitir futuras leituras e assim a monitorização periódica da estrutura. Foi ainda desenvolvido um sensor de humidade relativa do ar, com um material sol-gel, que permitiu registar o nível de humidade relativa no interior de blocos de betão, durante um ano. Este sensor pode ser incluído numa rede de sensores multiplexados, na caracterização e monitorização da integridade estrutural de certas estruturas de engenharia civil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este trabalho descreve o desenvolvimento e aplicação de sistemas baseados em detetores gasosos microestruturados, para imagiologia de fluorescência de raios-X por dispersão em energia (EDXRF). A técnica de imagiologia por fluorescência de raios-X assume-se como uma técnica poderosa, não-destrutiva, em análises da distribuição espacial de elementos em materiais. Os sistemas para imagiologia de EDXRF desenvolvidos são constituídos por: um tubo de raios-X, usado para excitar os elementos da amostra; um detetor gasoso microestruturado; e uma lente pinhole que foca a radiação de fluorescência no plano do detetor formando assim a imagem e permitindo a sua ampliação. Por outro lado é estudada a influência do diâmetro da abertura do pinhole bem como do fator de ampliação obtido para a imagem, na resolução em posição do sistema. Foram usados dois conceitos diferentes de detetores gasosos microestruturados. O primeiro, baseado na microestrutura designada por 2D-Micro-Hole & Strip Plate (2D-MHSP) com uma área ativa de 3 3 cm2, enquanto que o segundo, baseado na estrutura 2D-Thick-COBRA (2D-THCOBRA) apresenta uma área ativa de deteção de 10 10 cm2. Estes detetores de raios-X de baixo custo têm a particularidade de funcionar em regime de fotão único permitindo a determinação da energia e posição de interação de cada fotão que chega ao detetor. Deste modo permitem detetar a energia dos fotões X de fluorescência, bem como obter imagens 2D da distribuição desses fotões X para o intervalo de energias desejado. São por isso adequados a aplicações de imagiologia de EDXRF. Os detetores desenvolvidos mostraram resoluções em energia de 17% e 22% para fotões incidentes com uma energia de 5.9 keV, respectivamente para o detetor 2D-MHSP e 2D-THCOBRA e resoluções em posição adequadas para um vasto número de aplicações. Ao longo deste trabalho é detalhado o desenvolvimento, o estudo das características e do desempenho de cada um dos detetores, e sua influência na performance final de cada sistema proposto. Numa fase mais avançada apresentam-se os resultados correspondentes à aplicação dos dois sistemas a diversas amostras, incluindo algumas do nosso património cultural e também uma amostra biológica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

K0.5Na0.5NbO3 (KNN), is the most promising lead free material for substituting lead zirconate titanate (PZT) which is still the market leader used for sensors and actuators. To make KNN a real competitor, it is necessary to understand and to improve its properties. This goal is pursued in the present work via different approaches aiming to study KNN intrinsic properties and then to identify appropriate strategies like doping and texturing for designing better KNN materials for an intended application. Hence, polycrystalline KNN ceramics (undoped, non-stoichiometric; NST and doped), high-quality KNN single crystals and textured KNN based ceramics were successfully synthesized and characterized in this work. Polycrystalline undoped, non-stoichiometric (NST) and Mn doped KNN ceramics were prepared by conventional ceramic processing. Structure, microstructure and electrical properties were measured. It was observed that the window for mono-phasic compositions was very narrow for both NST ceramics and Mn doped ceramics. For NST ceramics the variation of A/B ratio influenced the polarization (P-E) hysteresis loop and better piezoelectric and dielectric responses could be found for small stoichiometry deviations (A/B = 0.97). Regarding Mn doping, as compared to undoped KNN which showed leaky polarization (P-E) hysteresis loops, B-site Mn doped ceramics showed a well saturated, less-leaky hysteresis loop and a significant properties improvement. Impedance spectroscopy was used to assess the role of Mn and a relation between charge transport – defects and ferroelectric response in K0.5Na0.5NbO3 (KNN) and Mn doped KNN ceramics could be established. At room temperature the conduction in KNN which is associated with holes transport is suppressed by Mn doping. Hence Mn addition increases the resistivity of the ceramic, which proved to be very helpful for improving the saturation of the P-E loop. At high temperatures the conduction is dominated by the motion of ionized oxygen vacancies whose concentration increases with Mn doping. Single crystals of potassium sodium niobate (KNN) were grown by a modified high temperature flux method. A boron-modified flux was used to obtain the crystals at a relatively low temperature. XRD, EDS and ICP analysis proved the chemical and crystallographic quality of the crystals. The grown KNN crystals exhibit higher dielectric permittivity (29,100) at the tetragonal-to-cubic phase transition temperature, higher remnant polarization (19.4 μC/cm2) and piezoelectric coefficient (160 pC/N) when compared with the standard KNN ceramics. KNN single crystals domain structure was characterized for the first time by piezoforce response microscopy. It could be observed that <001> - oriented potassium sodium niobate (KNN) single crystals reveal a long range ordered domain pattern of parallel 180° domains with zig-zag 90° domains. From the comparison of KNN Single crystals to ceramics, It is argued that the presence in KNN single crystal (and absence in KNN ceramics) of such a long range order specific domain pattern that is its fingerprint accounts for the improved properties of single crystals. These results have broad implications for the expanded use of KNN materials, by establishing a relation between the domain patterns and the dielectric and ferroelectric response of single crystals and ceramics and by indicating ways of achieving maximised properties in KNN materials. Polarized Raman analysis of ferroelectric potassium sodium niobate (K0.5Na0.5)NbO3 (KNN) single crystals was performed. For the first time, an evidence is provided that supports the assignment of KNN single crystals structure to the monoclinic symmetry at room temperature. Intensities of A′, A″ and mixed A′+A″ phonons have been theoretically calculated and compared with the experimental data in dependence of crystal rotation, which allowed the precise determination of the Raman tensor coefficients for (non-leaking) modes in monoclinic KNN. In relation to the previous literature, this study clarifies that assigning monoclinic phase is more suitable than the orthorhombic one. In addition, this study is the basis for non-destructive assessments of domain distribution by Raman spectroscopy in KNN-based lead-free ferroelectrics with complex structures. Searching a deeper understanding of the electrical behaviour of both KNN single crystal and polycrystalline materials for the sake of designing optimized KNN materials, a comparative study at the level of charge transport and point defects was carried out by impedance spectroscopy. KNN single crystals showed lower conductivity than polycrystals from room temperature up to 200 ºC, but above this temperature polycrystalline KNN displays lower conductivity. The low temperature (T < 200 ºC) behaviour reflects the different processing conditions of both ceramics and single crystals, which account for less defects prone to charge transport in the case of single crystals. As temperature increases (T > 200 ºC) single crystals become more conductive than polycrystalline samples, in which grain boundaries act as barriers to charge transport. For even higher temperatures the conductivity difference between both is increased due to the contribution of ionic conduction in single crystals. Indeed the values of activation energy calculated to the high temperature range (T > 300 ºC) were 1.60 and 0.97 eV, confirming the charge transport due to ionic conduction and ionized oxygen vacancies in single crystals and polycrystalline KNN, respectively. It is suggested that single crystals with low defects content and improved electromechanical properties could be a better choice for room temperature applications, though at high temperatures less conductive ceramics may be the choice, depending on the targeted use. Aiming at engineering the properties of KNN polycrystals towards the performance of single crystals, the preparation and properties study of (001) – oriented (K0.5Na0.5)0.98Li0.02NbO3 (KNNL) ceramics obtained by templated grain growth (TGG) using KNN single crystals as templates was undertaken. The choice of KNN single crystals templates is related with their better properties and to their unique domain structure which were envisaged as a tool for templating better properties in KNN ceramics too. X-ray diffraction analysis revealed for the templated ceramics a monoclinic structure at room temperature and a Lotgering factor (f) of 40% which confirmed texture development. These textured ceramics exhibit a long range ordered domain pattern consisting of 90º and 180º domains, similar to the one observed in the single crystals. Enhanced dielectric (13017 at TC), ferroelectric (2Pr = 42.8 μC/cm2) and piezoelectric (d33 = 280 pC/N) properties are observed for textured KNNL ceramics as compared to the randomly oriented ones. This behaviour is suggested to be due to the long range ordered domain patterns observed in the textured ceramics. The obtained results as compared with the data previously reported on texture KNN based ceramics confirm that superior properties were found due to ordered repeated domain pattern. This study provides an useful approach towards properties improvement of KNN-based piezoelectric ceramics. Overall, the present results bring a significant contribution to the pool of knowledge on the properties of sodium potassium niobate materials: a relation between the domain patterns and di-, ferro-, and piezo-electric response of single crystals and ceramics was demonstrated and ways of engineering maximised properties in KNN materials, for example by texturing were established. This contribution is envisaged to have broad implications for the expanded use of KNN over the alternative lead-based materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La construction dans l’Arctique nécessite une connaissance précise des propriétés thermiques et géotechniques du pergélisol. La connaissance de ces propriétés est également nécessaire pour le paramétrage des modèles de transfert de chaleur. Des études antérieures ont démontré le grand potentiel de l’utilisation de la tomodensitométrie pour les mesures du volume des composantes du pergélisol et la visualisation de la cryostructure. Une nouvelle approche est proposée pour mesurer la conductivité thermique du pergélisol. Les objectifs généraux de ce projet sont (1) d’élaborer une nouvelle méthode de caractérisation du pergélisol à l’aide de la tomodensitométrie et de modèle éprouvés et (2) de comparer et mettre au point une méthode novatrice pour mesurer la conductivité thermique et des paramètres géotechniques. Les résultats démontrent que les tests effectués à l’aide de la tomodensitométrie donnent des résultats d’une valeur scientifique comparable aux autres méthodes existantes de mesure de déjà existantes de conductivité thermique du pergélisol.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tese de doutoramento, Física, Universidade de Lisboa, Faculdade de Ciências, 2013

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Drilling of carbon fibre/epoxy laminates is usually carried out using standard drills. However, it is necessary to adapt the processes and/or tooling as the risk of delamination, or other damages, is high. These problems can affect mechanical properties of produced parts, therefore, lower reliability. In this paper, four different drills – three commercial and a special step (prototype) – are compared in terms of thrust force during drilling and delamination. In order to evaluate damage, enhanced radiography is applied. The resulting images were then computational processed using a previously developed image processing and analysis platform. Results show that the prototype drill had encouraging results in terms of maximum thrust force and delamination reduction. Furthermore, it is possible to state that a correct choice of drill geometry, particularly the use of a pilot hole, a conservative cutting speed – 53 m/min – and a low feed rate – 0.025 mm/rev – can help to prevent delamination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A utilização da madeira enquanto material estrutural é um aspeto abordado com algum receio ou até desconhecimento por parte dos elementos intervenientes no processo de construção civil, sendo ainda uma área pouco lecionada e muitas vezes excluída dos planos curriculares em Engenharia Civil. Assim sendo é importante o surgimento de trabalhos relacionados com esta matéria, relembrando ao sector da construção civil e ao ramo de estudo relacionado, que a madeira já teve e possivelmente voltará a ter um papel importante a desempenhar na área da construção. Um dos aspetos evidenciados nos estudos realizados consiste na importância da reabilitação de edifícios e do seu papel cada vez mais determinante na sociedade. Esta metodologia de intervenção apresenta-se muitas vezes como uma vantagem económica assim como contribui para a preservação do património arquitetónico e cultural, cujo valor histórico é incalculável. A importância da reabilitação de edifícios habitacionais nas zonas históricas, bem como de monumentos de grande importância cultural apresenta-se cada vez mais como um desafio devido à falta de conservação dos mesmos ao longo da sua vida útil, e da necessidade de preservar a identidade do local, beneficiando assim a qualidade do tecido urbano. Assim sendo, este trabalho apresenta um levantamento dos danos possíveis de ocorrer em elementos de madeira, dando especial destaque aos agentes patológicos e às consequências da sua atividade na madeira assim como às metodologias de inspeção e diagnóstico que poderão ser aplicadas em estruturas de madeira existentes, favorecendo assim a vertente da reabilitação ao invés da demolição. Estas metodologias recorrem a ensaios não destrutivos, como é exemplo o Pilodyn, o Resistógrafo, o Ultra-sons, etc., referindo também o recurso a ensaios destrutivos, cuja utilização terá de ser uma questão muito bem ponderada devido às consequências que implica. Por fim, apresenta-se um caso real de estudo em que se analisa um pavimento em madeira através da aplicação de metodologias de ensaio não destrutivas e destrutivas a amostras recolhidas. O objetivo será determinar o estado de conservação da madeira e algumas características físicas tais como a sua densidade e os módulos de elasticidade, sendo posteriormente efetuada uma análise estrutural. Os resultados obtidos permitem efetuar uma avaliação qualitativa do estado geral do pavimento sendo as principais conclusões que o pavimento se encontra atacado por parte de insetos xilófagos e apresenta problemas a nível de verificação a estados limite de utilização, deformação e vibração, fator que condiciona a possível utilização do pavimento.