871 resultados para fast reactor
Resumo:
In this thesis concurrent communication event handling is implemented using thread pool approach. Concurrent events are handled with a Reactor design pattern and multithreading is implemented using a Leader/Followers design pattern. Main focus is to evaluate behaviour of implemented model by different numbers of concurrent connections and amount of used threads. Furthermore, model feasibility in a PeerHood middleware is evaluated. Implemented model is evaluated with created test environment which enables concurrent message sending from multiple connections to the system under test. Messages round trip times are measured in the tester application. In the evaluation processing delay into system is simulated and influence of delay to the average round trip time is analysed.
Resumo:
Natriumhypokloriittia voidaan valmistaa kloorista ja lipeästä jatkuvatoimisessa absorberissa. Tässä työssä tutkittiin kokeellisesti, miten kaasun ja nesteen virtausnopeudet vaikuttavat täytekappalekolonnin tulvimiseen ja painehäviöön, kuinka nopeasti kloori absorboituu lipeään ja kuinka suuri hypokloriittiliuoksen kierrätys tarvitaan, ettei hypokloriitti ala hajota. Lisäksi luotiin matemaattinen malli, jolla voidaan mitoittaa jatkuvatoiminen vastavirtaperiaatteella toimiva natriumhypokloriittireaktori. Kloori–lipeäsysteemin havaittiin tulvivan suuremmilla virtausnopeuksilla kuin ilma–vesisysteemin. Tosin osa kloorista absorboituu jo ennen täytekappalekerrosta, minkä vuoksi kaasun todellinen virtausnopeus täytekappalekerroksen alaosassa on pienempi kuin mitattu arvo. Kolonnin painehäviö nousee erittäin jyrkästi tulvimispisteen läheisyydessä. Koska kloori absorboituu lähes täydellisesti ja vain kolonnin alaosa tulvii, voidaan kolonnia painehäviön kannalta operoida lähellä tulvimispistettä. Sekä mallinnuksen että koetulosten perusteella yli 99,99 % kloorista absorboituu koeolosuhteissa kahden metrin täytekappalekerroksessa. Nopea absorptio johtuu erittäin nopeasta, irreversiibelistä kloorin reaktiosta ja prosessille tyypillisestä natriumhydroksidikonversion rajoittamisesta alle 94 %:iin. Jotta varmistetaan, ettei hypokloriitti ala hajota, valmista hypokloriittiliuosta täytyy kierrättää kolonniin vähintään noin 4-kertainen määrä tuoreen lipeän syöttömäärän nähden.
Resumo:
Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and break- through volume were investigated. The method's enrichment factor and detection limit are 300 and 45.5 pg mL-1, respectively. The maximum capacity of the 10 mg of modified silylated MCM-41 was found to be 400.5±4.7 µg for Cr(III). The method was applied to the determination of Cr(III) and Cr(VI) in the wastewater of the chromium electroplating industry and in environmental and biological samples (black tea, hot and black pepper).
Resumo:
Soitinnus: piano.
Resumo:
Amyloid aggregation is linked to a large number of human disorders, from neurodegenerative diseases as Alzheimer"s disease (AD) or spongiform encephalopathies to non-neuropathic localized diseases as type II diabetes and cataracts. Because the formation of insoluble inclusion bodies (IBs) during recombinant protein production in bacteria has been recently shown to share mechanistic features with amyloid self-assembly, bacteria have emerged as a tool to study amyloid aggregation. Herein we present a fast, simple, inexpensive and quantitative method for the screening of potential anti-aggregating drugs. This method is based on monitoring the changes in the binding of thioflavin-S to intracellular IBs in intact Eschericchia coli cells in the presence of small chemical compounds. This in vivo technique fairly recapitulates previous in vitro data. Here we mainly use the Alzheimer"s related beta-amyloid peptide as a model system, but the technique can be easily implemented for screening inhibitors relevant for other conformational diseases simply by changing the recombinant amyloid protein target. Indeed, we show that this methodology can be also applied to the evaluation of inhibitors of the aggregation of tau protein, another amyloidogenic protein with a key role in AD.
Resumo:
Amyloid aggregation is linked to a large number of human disorders, from neurodegenerative diseases as Alzheimer"s disease (AD) or spongiform encephalopathies to non-neuropathic localized diseases as type II diabetes and cataracts. Because the formation of insoluble inclusion bodies (IBs) during recombinant protein production in bacteria has been recently shown to share mechanistic features with amyloid self-assembly, bacteria have emerged as a tool to study amyloid aggregation. Herein we present a fast, simple, inexpensive and quantitative method for the screening of potential anti-aggregating drugs. This method is based on monitoring the changes in the binding of thioflavin-S to intracellular IBs in intact Eschericchia coli cells in the presence of small chemical compounds. This in vivo technique fairly recapitulates previous in vitro data. Here we mainly use the Alzheimer"s related beta-amyloid peptide as a model system, but the technique can be easily implemented for screening inhibitors relevant for other conformational diseases simply by changing the recombinant amyloid protein target. Indeed, we show that this methodology can be also applied to the evaluation of inhibitors of the aggregation of tau protein, another amyloidogenic protein with a key role in AD.
Resumo:
BACKGROUND: The Cancer Fast-track Programme's aim was to reduce the time that elapsed between well-founded suspicion of breast, colorectal and lung cancer and the start of initial treatment in Catalonia (Spain). We sought to analyse its implementation and overall effectiveness. METHODS: A quantitative analysis of the programme was performed using data generated by the hospitals on the basis of seven fast-track monitoring indicators for the period 2006-2009. In addition, we conducted a qualitative study, based on 83 semistructured interviews with primary and specialised health professionals and health administrators, to obtain their perception of the programme's implementation. RESULTS: About half of all new patients with breast, lung or colorectal cancer were diagnosed via the fast track, though the cancer detection rate declined across the period. Mean time from detection of suspected cancer in primary care to start of initial treatment was 32 days for breast, 30 for colorectal and 37 for lung cancer (2009). Professionals associated with the implementation of the programme showed that general practitioners faced with suspicion of cancer had changed their conduct with the aim of preventing lags. Furthermore, hospitals were found to have pursued three specific implementation strategies (top-down, consensus-based and participatory), which made for the cohesion and sustainability of the circuits. CONCLUSION: The programme has contributed to speeding up diagnostic assessment and treatment of patients with suspicion of cancer, and to clarifying the patient pathway between primary and specialised care.
Resumo:
The decolorization of acid orange 7 azo dye by photolysis and photocatalysis by ZnO was investigated in the presence of oxidants such as NaClO3, NaBrO3, NaIO4, and K2S2O8 in an open reactor at 30 ºC. The decolorization was relatively fast at lower oxidants concentrations and slow rate at larger concentrations, except for persulfate in the photocatalysis. Concerning photolysis the rate constant enhanced gradually, except for chlorate, outreaching the obtained values by photocatalysis, at higher concentrations. The air saturation decreased the rate constant in both processes and indicated that the azo dye can be decolorized without dissolved oxygen in persulfate medium.
Resumo:
This work deals with the method validation for the determination of acetic, propionic and butyric acids (VFAs) in wastewaters from anaerobic reactors by HPLC-DAD. Separation was performed using a C18 column and the mobile phase composition were water pH 3.0 and methanol 90:10 (v/v). The detection and quantification was carried out at 220 nm. The method shows good linearity (r²>0.996), with adequate accuracy (89-102%) and relative standard deviations lower than 18%. The matrix effect was considered low (-4.1, -3.9 and 1.4%). The developed method is fast, simple and cheap; and it was applied in wastewater samples from anaerobic reactor.
Resumo:
A fast gas chromatography with a flame ionisation detector (GC-FID) method for the simultaneous analysis of methyl palmitate (C16:0), stearate (C18:0), oleate (C18:1), linoleate (C18:2) and linolenate (C18:3) in biodiesel samples was proposed. The analysis was conducted in a customised ionic-liquid stationary-phase capillary, SLB-IL 111, with a length of 14 m, an internal diameter of 0.10 mm, a film thickness of 0.08 µm and operated isothermally at 160 °C using hydrogen as the carrier gas at a rate of 50 cm s-1 in run time about 3 min. Once methyl myristate (C14:0) is present lower than 0.5% m/m in real samples it was used as an internal standard. The method was successful applied to monitoring basic and acidic catalysis transesterification reactions of vegetable oils such as soybean, canola, corn, sunflower and those used in frying process.
Resumo:
In the theoretical part, the different polymerisation catalysts are introduced and the phenomena related to mixing in the stirred tank reactor are presented. Also the advantages and challenges related to scale-up are discussed. The aim of the applied part was to design and implement an intermediate-sized reactor useful for scale-up studies. The reactor setting was tested making one batch of Ziegler–Natta polypropylene catalyst. The catalyst preparation with a designed equipment setting succeeded and the catalyst was analysed. The analyses of the catalyst were done, because the properties of the catalyst were compared to the normal properties of Ziegler–Natta polypropylene catalyst. The total titanium content of the catalyst was slightly higher than in normal Ziegler–Natta polypropylene catalyst, but the magnesium and aluminium content of the catalyst were in the normal level. By adjusting the siphonation tube and adding one washing step the titanium content of the catalyst could be decreased. The particle size of the catalyst was small, but the activity was in a normal range. The size of the catalyst particles could be increased by decreasing the stirring speed. During the test run, it was noticed that some improvements for the designed equipment setting could be done. For example more valves for the chemical feed line need to be added to ensure inert conditions during the catalyst preparation. Also nitrogen for the reactor needs to separate from other nitrogen line. With this change the pressure in the reactor can be kept as desired during the catalyst preparation. The proposals for improvements are presented in the applied part. After these improvements are done, the equipment setting is ready for start-up. The computational fluid dynamics model for the designed reactor was provided by cooperation with Lappeenranta University of Technology. The experiments showed that for adequate mixing with one impeller, stirring speed of 600 rpm is needed. The computational fluid dynamics model with two impellers showed that there was no difference in the mixing efficiency if the upper impeller were pumping downwards or upwards.
Resumo:
A flow injection spectrophotometric procedure with on-line solid-phase reactor containing ion triiodide immobilized in an anion-exchange resin is proposed for the determination of adrenaline (epinephrine) in pharmaceutical products. Adrenaline is oxidized by triiodide ion immobilized in an anionic-exchange resin yielding adrenochrome which is transported by the carrier solution and detected at a wavelength of 488 nm. Adrenaline was determined in three pharmaceutical products in the 6.4 x 10-6 to 3.0 x 10-4 mol L-1 concentration range with a detection limit of 4.8 x 10-7 mol L-1. The recovery of this analyte in three samples ranged from 96.0 to 105 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1 % for adrenaline concentrations of 6.4 x 10-5 and 2.0 x 10-4 mol L-1 (n=10). A paired t-test showed that all results obtained for adrenaline in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.
Resumo:
A photometric flow titration based on the redox reaction between KMnO4 and minoxidil is described. The best titration results were observed at 3.20 x 10-4 mol L-1 KMnO4 and 1.00 x 10-3 mol L-1 minoxidil, using the minoxidil solutions as titrant. The flow rate was fixed at 17 mL min-1 and the titrant was added to the system in aliquots of 500 µL, the color changes were monitored at 550 nm. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.6 to 102.8 % were observed depending on the sample. Comparison with the chromatographic procedure reveled relative errors of 3.5 - 4.0 %.
Resumo:
The goal of this work was to develop a simple and rapid preparation method for patulin analysis in apple juice without previous clean-up. This method combined sonication and liquid extraction techniques and was used for determination of patulin in 37 commercial apple juices available on the market in the South of Brazil. The method performance characteristics were determined using a sample obtained in a local market fortified at five concentration levels of patulin and done in triplicates. The coefficient of variation for repeatability at the fortification level of 20.70µg.L-1 was 3.53 % and the recovery 94.63 %, respectively. The correlation coefficient was 0.9996 and agrees with the requirements for a linear analytical method value. The detection limit was 0.21µg.L-1 and the quantification limit 0.70 µg.L-1. Only three of the analyzed samples were upper the allowed level of 50.00 µg.L-1 recommended for the World Health Organization.