889 resultados para Reconfiguration of electrical distribution systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper contains a study of the synchronization by homogeneous nonlinear driving of systems that are symmetric in phase space. The main consequence of this symmetry is the ability of the response to synchronize in more than just one way to the driving systems. These different forms of synchronization are to be understood as generalized synchronization states in which the motions of drive and response are in complete correlation, but the phase space distance between them does not converge to zero. In this case the synchronization phenomenon becomes enriched because there is multistability. As a consequence, there appear multiple basins of attraction and special responses to external noise. It is shown, by means of a computer simulation of various nonlinear systems, that: (i) the decay to the generalized synchronization states is exponential, (ii) the basins of attraction are symmetric, usually complicated, frequently fractal, and robust under the changes in the parameters, and (iii) the effect of external noise is to weaken the synchronization, and in some cases to produce jumps between the various synchronization states available

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine the incidence and risk factors of electrical seizures and other electrical epileptic activity using continuous EEG (cEEG) in patients with acute stroke. METHODS: One hundred consecutive patients with acute stroke admitted to our stroke unit underwent cEEG using 10 electrodes. In addition to electrical seizures, repetitive focal sharp waves (RSHWs), repetitive focal spikes (RSPs), and periodic lateralized epileptic discharges (PLEDs) were recorded. RESULTS: In the 100 patients, cEEG was recorded for a mean duration of 17 hours 34 minutes (range 1 hour 12 minutes to 37 hours 10 minutes). Epileptic activity occurred in 17 patients and consisted of RSHWs in seven, RSPs in seven, and PLEDs in three. Electrical seizures occurred in two patients. On univariate Cox regression analysis, predictors for electrical epileptic activity were stroke severity (high score on the National Institutes of Health Stroke Scale) (hazard ratio [HR] 1.12; p = 0.002), cortical involvement (HR 5.71; p = 0.021), and thrombolysis (HR 3.27; p = 0.040). Age, sex, stroke type, use of EEG-modifying medication, and cardiovascular risk factors were not predictors of electrical epileptic activity. On multivariate analysis, stroke severity was the only independent predictor (HR 1.09; p = 0.016). CONCLUSION: In patients with acute stroke, electrical epileptic activity occurs more frequently than previously suspected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lappeenrannan teknillisen korkeakoulun sähkötekniikan osasto muutti 1.8.2005 sähkötekniikan tutkinnon kaksiportaiseksi ja vastaamaan näin Bologna-prosessia ja Suomen yliopistolainsäädäntöä. Tutkinnonuudistuksen myötä osasto haluaa varmistaa sähkötekniikan tutkintojen laadun ja vertailtavuuden sekä parantaa opiskelijoidensekä henkilökunnan liikkuvuutta. Tutkintojen laatu ja vertailtavuus osoitetaan sähkötekniikan osaston benchmark-projektilla, jossa kerätään tietoja maisteri- ja tohtorintutkintoa tarjoavista eurooppalaisista yliopistoista. Diplomityö käsittää BM-projektin kolmannen vaiheen suunnittelun ja toteutuksen sisältäen teoriaa benchmark-projekteille tyypillisistä toimintatavoista. Hyväksi havaitut menetelmiä, kuten kyselyt ja matriisit, on tässä työssä otettu soveltuvin osin sähkötekniikan osaston BM-projektin työkaluiksi. Diplomityössä analysoidaan työkalujen avulla BM-kumppaneilta kerättyjä tietoja sekä esitetään ratkaisuja, miten sähkötekniikan osastolla voidaan jatkaa parhaiden toimintatapojen löytämistä.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Talouden kasvaessa myös tavarankuljetusmäärät kasvavat. Kuljetusjärjestelmät ja niiden sujuva toiminta on erittäin tärkeää taloudellisen kasvun kannalta tällä hetkellä, ja se tulee olemaan yhä tärkeämpää tulevaisuudessa. Tulevaisuudessa tarvitaan kokonaisvaltainen ja selkeästi tehokkaampi kuljetusjärjestelmä, mikäli tulevaisuuden kuljetusvirrat halutaan hoitaa kestävästi. Tässä opinnäytetyössäni tutkin kolmen eurooppalaisen kuljetusjärjestelmän (rautatiet, lentoliikenne ja konttiliikenne meritse) suhteellista teknistä tehokkuutta ja menetelmänä on data envelopment analysis (DEA). Vertailtaessa kuljetusjärjestelmiä löytyi suuria eroja kuljetusmuotojen välille. lentoyhtiöt suoriutuivat huomattavan tasaisesti eli tehokkaiden ja ei-tehokkaiden toimijoiden välillä ei ollut suuria eroja. Rautatiepuolella erot venyivät huomattavan suuriksi niin eri yritysten välillä kuin jopa saman yrityksen sisällä eri vuosina. Pikaisemmassa laivayhtiöiden tarkastelussa erot niiden välillä olivat lähes yhtä pieniä kuin lentoyhtiöiden välillä. Tarkasteltaessa omistajuuden vaikutusta lentoyhtiöiden toiminnassa huomattiin, että yksityisessä omistuksessa olevat yritykset olivat huomattavasti tehokkaampia matkustajien kuljettamisessa. Rahtipuolella merkittäviä eroja ei havaittu. Merkittävät korrelaatiot eri mallien välillä antoivat joitain viitteitä myös kuljetuspoliittiseen päätöksentekoon; investoinnit matkustajienkuljetuksiin raiteilla parantaisivat koko rautatiepuolen teokkuutta, mutta myös samalla lentopuolen matkustajakuljetuksen tehokkuutta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: As it might lead to less discomfort, magnetic nerve stimulation (MNS) is increasingly used as an alternative to electrical stimulation methods. Yet, MNS and electrical nerve stimulation (ENS) and electrical muscle stimulation (EMS) have not been formally compared for the evaluation of plantar flexor neuromuscular function. METHODS: We quantified plantar flexor neuromuscular function with ENS, EMS and MNS in 10 volunteers in fresh and fatigued muscles. Central alterations were assessed through changes in voluntary activation level (VAL) and peripheral function through changes in M-wave, twitch and doublet (PS100) amplitudes. Discomfort associated with 100-Hz paired stimuli delivered with each method was evaluated on a 10-cm visual analog scale. RESULTS: VAL, agonist and antagonist M-wave amplitudes and PS100 were similar between the different methods in both fresh and fatigued states. Potentiated peak twitch was lower in EMS compared to ENS, whereas no difference was found between ENS and MNS for any parameter. Discomfort associated with MNS (1.5 ± 1.4 cm) was significantly less compared to ENS (5.5 ± 1.9 cm) and EMS (4.2 ± 2.6 cm) (p < 0.05). CONCLUSION: When PS100 is used to evaluate neuromuscular properties, MNS, EMS and ENS can be used interchangeably for plantar flexor neuromuscular function assessment as they provide similar evaluation of central and peripheral factors in unfatigued and fatigued states. Importantly, electrical current spread to antagonist muscles was similar between the three methods while discomfort from MNS was much less compared to ENS and EMS. MNS may be potentially employed to assess neuromuscular function of plantar flexor muscles in fragile populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämän tutkielman tavoitteena on perehtyä globaalin yrityksen laskentatoimen tietojärjestelmien yhtenäistämiseen ja käyttöönottoon esimerkkinä UPM-Kymmene konsernin projekti. Tutkielmassa sovelletaan hermeneuttista tutkimusotetta. Teoreettisesti aihetta tarkastellaan globalisoitumisen ja laskentatoimen tietojärjestelmille asetettavien vaatimusten pohjalta, sekä järjestelmän muutosprosessin eri vaiheissa huomioon otettavien muuttujien perusteella. Yhtenäisen laskentatoimen tietojärjestelmän tuomat edut globaalille yritykselle ovat ilmeisiä. Ennen yhtenäisen projektin kehittelyä on olennaista tutkia lähtökohdat projektin onnistumiselle ja suunnitella projektin eri vaiheet huolella. Tutkielmassa havaitaan myös, että globaalissa yrityksessä tulee huomioida eri yrityskulttuurit sekä tulosyksiköiden erilaiset toimintatavat. Johtopäätöksenä todetaan, että sekä yritysjohdon että tulosyksiköiden sitoutuneisuus projektiin ja yhtenäiset tavoitteet ovat oleellisia projektin onnistumisen kannalta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää Stora Enso Oyj:llä käytössä olevan Fenix myynnin- ja logistiikanhallintajärjestelmän logistiikkapalveluiden suorituskyky, tuottaa asiakasohjelmisto suorituskykymittauksista muodostuneen tiedon hallintaan sekä tuottaa toteuttamissuunnitelma suorituskyvyn parantamiseksi. Suorituskyky mitattiin käyttämällä TUXEDOn tarjoamia ominaisuuksia. Suorituskykymittausten tuloksien arviointia varten rakennettiin asiakasohjelmisto, jolla pystyttiin tuottamaan tarvittavat yhteenvetotiedot palveluiden kestoista ja rakenteista. Valmiita ratkaisuja ei ollut tarjolla, joten kaikki tarvittavat ohjelmistot on rakennettu osana tätä työtä. Kaikki komponenttiliittymät toteutettiin siten, että myös muitakin kuin logistiikkaan liittyviä palveluita voidaan tarvittaessa mitata. Mittausten tuloksena saatuja keskimääräisiä suoritusaikoja käytettiin hyväksi toteuttamissuunnitelmaa tehdessä. Toteutussuunnitelma sisältää useiden logistiikka-alueiden kehittämisideoita, joilla Fenixin logistiikkapalveluiden suorituskykyä voidaan tehostaa., ja nykyinen järjestelmän toimintanopeus pystytään säilyttämään tulevaisuudessa. Toteuttamissuunnitelmassa esitettyjä toimenpiteitä tullaan toteuttamaan TietoEnator Oyj:ssä vuoden 2003 aikana.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Very large molecular systems can be calculated with the so called CNDOL approximate Hamiltonians that have been developed by avoiding oversimplifications and only using a priori parameters and formulas from the simpler NDO methods. A new diagonal monoelectronic term named CNDOL/21 shows great consistency and easier SCF convergence when used together with an appropriate function for charge repulsion energies that is derived from traditional formulas. It is possible to obtain a priori molecular orbitals and electron excitation properties after the configuration interaction of single excited determinants with reliability, maintaining interpretative possibilities even being a simplified Hamiltonian. Tests with some unequivocal gas phase maxima of simple molecules (benzene, furfural, acetaldehyde, hexyl alcohol, methyl amine, 2,5 dimethyl 2,4 hexadiene, and ethyl sulfide) ratify the general quality of this approach in comparison with other methods. The calculation of large systems as porphine in gas phase and a model of the complete retinal binding pocket in rhodopsin with 622 basis functions on 280 atoms at the quantum mechanical level show reliability leading to a resulting first allowed transition in 483 nm, very similar to the known experimental value of 500 nm of "dark state." In this very important case, our model gives a central role in this excitation to a charge transfer from the neighboring Glu(-) counterion to the retinaldehyde polyene chain. Tests with gas phase maxima of some important molecules corroborate the reliability of CNDOL/2 Hamiltonians.