503 resultados para Infiltração vítrea
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The adoption of management practices that reduce water losses is essential to conserve moisture and improve soil temperature, especially in arid and semiarid environments of the Brazilian Northeast, characterized by high evapotranspiration and the adoption of irrigation with saline water, which harms growth and yield of commercial crops. Given these factories, an experiment was conducted in Nova Floresta, Paraiba, from August 2010 to February 2011 in Oxisoil, in order to evaluate the production of bell pepper and soil moisture in grooves with side trim, and application of biofertilizer and mulch cattle. The experimental design was randomized blocks with four replications using a factorial 2 x 2 x 2 for the ground beef with and without biofertilizer, with and without residues of sisal fiber (Agave sisalana), with and without the side facing the grooves, to reduce lateral water losses by infiltration of water with polyethylene plastic film. From the results, the lining of the lateral grooves provided higher values of soil moisture, number of fruits, fruit mass, plant production and productivity, bell pepper plants. It was also found that the combination of biofertilizer and mulch the ground beef remained wetter in the first 15 cm depth.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O objetivo deste trabalho foi avaliar o pH e a densidade óptica das soluções de azul de metileno a 1% e 2% (tamponadas e não tamponadas) após a imersão de três cimentos endodônticos. Foram preparados oitenta espécimes de cada cimento endodôntico (Endofill, AH Plus e Sealapex), os quais foram imersos nas soluções corantes. As soluções foram analisadas antes e após a imersão dos materiais nos períodos de tempo de 0, 24, 48 e 72h. Foram realizadas avaliações do pH utilizando um pHmetro e da densidade óptica utilizando um espectofotômetro ajustado em 596nm. Os dados de pH foram analisados através de estatística descritiva e os dados da densidade óptica foram analisados pela ANOVA e teste de Tukey 5%. Pôde-se verificar que as soluções corantes de azul de metileno tamponadas e não tamponadas apresentaram pequena variação nos valores de pH e densidade óptica antes do contato com os cimentos endodônticos. As soluções corantes não tamponadas apresentaram valores de pH menores que as tamponadas, independentemente do contato com qualquer cimento endodôntico. Os cimentos endodônticos promoveram alterações nos valores de pH das soluções corantes, sendo que as maiores alterações ocorreram nas soluções não tamponadas. Ocorreram alterações nos valores da densidade óptica das soluções corantes tamponadas e não tamponadas nos diferentes períodos de tempo de análise, sendo diferentes para cada cimento endodôntico utilizado
Resumo:
O Lago Azul (Rio Claro – SP), oriundo da canalização do Córrego Servidão, vem sofrendo com problemas de inundação, infiltração, erosão e contaminação das águas por esgoto. Alguns dos compostos mais despejados nas águas de rios, e responsáveis por tais problemas de contaminação são os detergentes biodegradáveis, que têm sido alvo de críticas, não apenas devido aos problemas de biodegradação, mas também devido ao fato de provocarem o fenômeno conhecido como eutrofização. A preocupação com a possível contaminação das espécies do Lago Azul levou a prefeitura de Rio Claro, junto da SABESP, a iniciar estudos das águas e sedimentos do Lago Azul. Visando essa preocupação o projeto pretende analisar os efeitos da água do Lago Azul e de uma diluição de detergentes em indivíduos de Prochilodus lineatus (Curimbatá), comparados a um controle exposto a água pura clorada do poço artesiano situado no Campus da UNESP de Rio Claro. O projeto procurou caracterizar o epitélio que recobre as escamas da espécie tratada, haja vista que se trata de uma estrutura inexplorada na literatura. A partir desses dados, análises foram realizadas através da detecção de possíveis alterações morfológicas na histologia e histoquímica das células epiteliais de escamas para avaliar os efeitos dos possíveis agentes contaminantes. Para as análises histológicas o material foi processado em resina para as técnicas de Alcian e PAS para detecção de polissacarídeos ácidos e básicos, Azul de Bromofenol para detecção de proteínas, Picrossirus Red para detecção de fibras colágenas I e III e Hematoxilina-Eosina para analisar alterações morfológicas. Os dados coletados foram analisados com auxílio de um microscópio Leica DM 2000, dotado de câmera para captura de imagens
Resumo:
Contamination of rivers and lakes, waste disposed by infiltration into the soil as fertilizer, for example, has been highlighted around the world, since such compounds can contain toxic elements, causing changes in aquatic and/or terrestrial ecosystem. Due to the possible presence of these elements in these wastes, it is possible assess damage to organisms exposed through breaks in genetic material and mutations. In this sense, this work aimed at exploring the cytotoxic, mutagenic and genotoxic vinasse pontential, residue used as fertilizer, from the processing of sugar cane into alcohol, using fish (Oreochromis niloticus - Cichlidae) as a test organism. The individuals were exposed to different dilutions of vinasse in the water and later carried out analysis of their erythrocytes using the micronucleus test and nuclear abnormalities associated and the comet assay. In the first bioassay, tilapia exhibited 5% and 10% vinasse concentrations died after 48h. The number of micronucleated erythrocytes was statistically significant for the 1% vinasse concentration and also for nuclear abnormalities such as broken-egg and nuclear bud, when compared with negative and positive controls; were also significant lobed type erythrocytes, when compared to the negative control. The test results of the comet assay were not significant for 1% vinasse when compared to the negative control, due to the high rate of comets with damage control, which is unusual. The same was observed for changes as notched and blebbed type. In the second chemical analyzes conducted, the detection of heavy metals in the vinasse sample, charged only the presence of copper and chromium, the latter with a concentration 89 times higher than in the first test. Differentially the first bioassay, fish exposed to dilution of 5% did not die... (Complete abstract click electronic access below)
Resumo:
The aim of this study was to verify through microtensile test the influence of time and concentration of surface conditioning with hydrofluoric acid and its interference in the adhesion of dual resin cement to porcelain.We used 32 bodies of glass-ceramic lithium disilicate system IPS e.max Press LT with dimensions of 6mm thick, 8 mm in length and 8 mm in length, which will be molded to obtain composite resin blocks corresponding to blocks ceramics. Ceramic and resin blocks were divided into 16 groups (n = 4) and numbered according to the concentration of hydrofluoric acid (2.5%, 5%, 7.5% and 10%) and conditioning time (20 seconds, 40 seconds, 1 minute and 2 minutes). The blocks were cleaned in ultrasonic apparatus with distilled water and dried with compressed air, subjected to acid etching and air-jet washed with water, dried with compressed air and received application of silane agent Monobond-S, followed by adhesive Excite ( Ivoclar Vivaden). Each ceramic block was bonded to the corresponding block of resin through the resin cement Multilink Automix. The specimens were cut to obtain nine micro samples for each set of ceramic-resin with 1 mm X 1 mm X 12 mm in length, which were submitted to microtensile test. The results were analyzed with descriptive statistics and analysis of variance with significance level of 5%, revealing that there were statistically significant (p = 0.000001 <0.05). From the Tukey test can be concluded that etching with hydrofluoric acid and 2.5% for 120 seconds gave the best bond strength, however, no statistical difference between the conditioning with the same acid in the concentration of 5.0% for 20 to 40 seconds
Resumo:
With the accelerated urbanization process of Brazil from the 50s, there was a disorderly occupation of spaces and consequent soil sealing. Unlike this growth, the support capacity of urban environments has not evolved in the same way, generating negative environmental impacts to the citizens. Among these impacts are the effects of flooding. In order to minimize the negative effects of extreme precipitation over cities, the government invests in corrective measures, like compensatory techniques on urban drainage, which have as a basic principle the retention and infiltration of the rainfall, dampening the peak flow and runoff. An example of applying these techniques in urban areas are the detention basins, commonly called large pools. The hydraulic design of these structures is dependent of complex data and variables, and projects involving small areas generally use simplified methods for defining the reservoirs volume of the storage (Tassi, 2005). One of these methods is presented in this study, which relates to the percentage of soil sealing to the specific storage volume (m³/ha) in combination by applying the hydrological model of the Rational Method and analyzing regional rainfall and soil occupation over the basin. Within this context, the basin of the Wenzel stream, which is located amidst the urban area of Rio Claro/SP, also presents the problems related to human occupation in its valley. Thus, by the method presented has been adjusted a curve correlating the percentage of impermeable area and the specific volume of a detention basin. For the current situation of Wenzel Basin with 82% of impermeable area, and return period of 10 years, the specific volume is 262.1 m³/ha. The presented method is consistent with the results of other studies in the area, and the expression obtained allows estimating the volume of storage required to match hydrograph pre and post-occupancy. It presents itself as a useful tool in the planning stage of...