956 resultados para Illuminated manuscripts


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Jabirian Corpus refers to the K. Thahirat Al-`Iskandar, ""The Book of the Treasure of Alexander"" (hereafter BTA), as one of several forgeries suggesting that alchemical secrets were hidden in inscriptions in various places. The book was neglected until 1926, when Julius Ruska discussed it in his work on the Emerald Tablet, placing the BTA within the literature related to the development of Arabic alchemy. His preliminary study became an essential reference and encouraged many scholars to work on the BTA in the following decades. Some years ago, we completed the first translation of the BTA into a Western language. The work was based on the acephalous Escorial manuscript, which we identified as a fourteenth-century copy of the BTA. This manuscript is peculiar, as part of it is encoded. After finishing our translation, we started to establish the text of the BTA. At present, the text is in process of fixation-to be followed by textual criticism-and has been the main focus of a thorough study of ours on medieval hermeticism and alchemy. A sample of the work currently in progress is presented in this paper: an analysis of the variations between different manuscripts along with a study and English translation of its alchemical chapter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Candiduria is a hospital-associated infection and a daily problem in the intensive care unit. The treatment of asymptomatic candiduria is not well established and the use of amphotericin B bladder irrigation (ABBI) is controversial. The aim of this systematic review was to determine the best place for this therapy in practice. Methods: The databases searched in this study included MEDLINE, EMBASE, Web of Science, and LILACS (January 1960-June 2007). We included manuscripts with data on the treatment of candiduria using ABBI. The studies were classified as comparative, dose-finding, or non-comparative. Results: From 213 studies, nine articles (377 patients) met our inclusion criteria. ABBI showed a higher clearance of the candiduria 24 hours after the end of therapy than fluconazole (odds ratio (OR) 0.57, 95% confidence interval (CI) 0.32-1.00). Fungal culture 5 days after the end of both therapies showed a similar response (OR 1.51, 95% CI 0.81-2.80). The evaluation of ABBI using an intermittent or continuous system of delivery showed an early candiduria clearance (24 hours after therapy) of 80% and 82%, respectively (OR 0.87, 95% CI 0.52-1.36). Candiduria clearance at >5 days after the therapy showed a superior response using continuous bladder irrigation with amphotericin B (OR 0.52, 95% CI 0.29-0.94). The use of continuous ABBI for more than 5 days showed a better result (88% vs. 78%) than ABBI for less than 5 days, but without significance (OR 0.55, 95% CI 0.34-1.04). Conclusion: Although the strength of the results in the underlying literature is not sufficient to allow the drawing of definitive conclusions, ABBI appears to be as effective as fluconazole, but it does not offer systemic antifungal therapy and should only be used for asymptomatic candiduria. (C) 2008 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the extent to which adults with Down syndrome (DS) are able to utilise advance information to prepare reach to grasp movements. The study comprised ten adults with DS; ten children matched to an individual in the group with DS on the basis of their intellectual ability, and twelve adult controls. The participants used their right hand to reach out and grasp illuminated perspex blocks. Four target blocks were positioned on a table surface, two to each side of the midsagittal plane. In the complete precue condition, participants were provided with information specifying the location of the target. In the partial precue condition, participants were given advance information indicating the location of the object relative to the midsagittal plane (left or right). In the null condition, advance information concerning the position of the target object was entirely ambiguous. It was found that both reaction times and movement times were greater for the participants with DS than for the adults without DS. The reaction times exhibited by individuals with DS in the complete precue condition were lower than those observed in the null condition, indicating that they had utilised advance information to prepare their movements. In the group with DS, when advance information specified only the location of the target object relative to the midline, reaction times were equivalent to those obtained when ambiguous information was given. In contrast, the adults without DS exhibited reaction times that were lower in both the complete and partial precue conditions when compared to the null condition. The pattern of results exhibited by the children was similar to that of the adults without DS. The movement times exhibited by all groups were not influenced by the precue condition. In summary, our findings indicate that individuals with DS are able to use advance information if it specifies precisely the location of the target object in order to prepare a reach to grasp movement. The group with DS were unable, however, to obtain the normal advantage of advance information specifying only one dimension of the movement goal (i.e., the position of an object relative to the body midline). (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To provide recommendations for the core outcome domains that should be considered by investigators conducting clinical trials of the efficacy and effectiveness of treatments for chronic pain. Development of a core set of outcome domains would facilitate comparison and pooling of data, encourage more complete reporting of outcomes, simplify the preparation and review of research proposals and manuscripts, and allow clinicians to make informed decisions regarding the risks and benefits of treatment. Methods. Under the auspices of the Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials (IMMPACT), 27 specialists from academia. governmental agencies, and the pharmaceutical industry participated in a consensus meeting and identified core outcome domains that should be considered in clinical trials of treatments for chronic pain. Conclusions. There was a consensus that chronic pain clinical trials should assess outcomes representing six core domains: (1) pain, (2) physical functioning, (3) emotional functioning, (4) participant ratings of improvement and satisfaction with treatment, (5) symptoms and adverse events, (6) participant disposition (e.g. adherence to the treatment regimen and reasons for premature withdrawal from the trial). Although consideration should be given to the assessment of each of these domains, there may be exceptions to the general recommendation to include all of these domains in chronic pain trials. When this occurs, the rationale for not including domains should be provided. It is not the intention of these recommendations that assessment of the core domains should be considered a requirement for approval of product applications by regulatory agencies or that a treatment must demonstrate statistically significant effects for all of the relevant core domains to establish evidence of its efficacy. (C) 2003 International Association for the Study of Pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An optically addressed read-write sensor based on two stacked p-i-n heterojunctions is analyzed. The device is a two terminal image sensing structure. The charge packets are injected optically into the p-i-n writer and confined at the illuminated regions changing locally the electrical field profile across the p-i-n reader. An optical scanner is used for charge readout. The design allows a continuous readout without the need for pixel-level patterning. The role of light pattern and scanner wavelengths on the readout parameters is analyzed. The optical-to-electrical transfer characteristics show high quantum efficiency, broad spectral response, and reciprocity between light and image signal. A numerical simulation supports the imaging process. A black and white image is acquired with a resolution around 20 mum showing the potentiality of these devices for imaging applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A two terminal optically addressed image processing device based on two stacked sensing/switching p-i-n a-SiC:H diodes is presented. The charge packets are injected optically into the p-i-n sensing photodiode and confined at the illuminated regions changing locally the electrical field profile across the p-i-n switching diode. A red scanner is used for charge readout. The various design parameters and addressing architecture trade-offs are discussed. The influence on the transfer functions of an a-SiC:H sensing absorber optimized for red transmittance and blue collection or of a floating anode in between is analysed. Results show that the thin a-SiC:H sensing absorber confines the readout to the switching diode and filters the light allowing full colour detection at two appropriated voltages. When the floating anode is used the spectral response broadens, allowing B&W image recognition with improved light-to-dark sensitivity. A physical model supports the image and colour recognition process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of large area single layers and heterojunction cells in the assembly glass/ZnO:Al/p (SixC1-x:H)/i (Si:H)/n (SixC1-x:H)/Al (0 illuminated current-voltage and capacitance-voltage characteristics. For the heterojunction cells S-shaped J-V characteristics under different illumination conditions are observed leading to poor fill factors. High serial resistances around 10(5)Ohm are also measured Simulated results confirm the experimental findings suggesting that the transport in dark depends almost exclusively on field-aided drift while under illumination it is dependent mainly on minority carriers the diffusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of large area single layers and glass/ZnO:AVp(SixC1-x:H)/i(Si:H)/n(SixC1-x:H)/AI (0 < x < 1) heterojunction cells were produced by plasma-enhanced chemical vapour deposition (PE-CVD) at low temperature. Junction properties, carrier transport and photogeneration are investigated from dark and illuminated current-voltage (J-V) and capacitance-voltage (C-V) characteristics. For the heterojunction cells atypical J-V characteristics under different illumination conditions are observed leading to poor fill factors. High series resistances around 106 Q are also measured. These experimental results were used as a basis for the numerical simulation of the energy band diagram, and the electrical field distribution of the structures. Further comparison with the sensor performance gave satisfactory agreement. Results show that the conduction band offset is the most limiting parameter for the optimal collection of the photogenerated carriers. As the optical gap increases and the conductivity of the doped layers decreases, the transport mechanism changes from a drift to a diffusion-limited process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An optimized ZnO:Al/a-pin SixCl1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed. The LSP utilizes light induced depletion layers as detector and a laser beam for readout. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Experimental data reveal that the large optical gap and the low conductivity of the doped a-SixC1-x:H layers are responsible by an induced inversion layer at the illuminated interfaces which blocks the carrier collection. These insulator-like layers act as MIS gates preventing image smearing. The physical background of the LSP is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An optimized ZnO:Al/a-pin SixC1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed and the read-out parameters improved. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Data reveals that for sensors with wide band gap doped layers an increase on the image signal optimized to the blue is achieved with a dynamic range of two orders of magnitude, a responsivity of 6 mA W-1 and a sensitivity of 17 muW cm(-2) at 530 nm. The main output characteristics such as image responsivity, resolution, linearity and dynamic range were analyzed under reverse, forward and short circuit modes. The results show that the sensor performance can be optimized in short circuit mode. A trade-off between the scan time and the required resolution is needed since the spot size limits the resolution due to the cross-talk between dark and illuminated regions leading to blurring effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents preliminary results in the study of a novel structure for a laser scanned photodiode (LSP) type of image sensor. In order to increase the signal output, a stacked p-i-n-p-i-n structure with an intermediate light-blocking layer is used. The image and the scanning beam are incident through opposite sides of the sensor and their absorption is kept in separate junctions by an intermediate light-blocking layer. As in the usual LSP structure the scanning beam-induced photocurrent is dependent on the local illumination conditions of the image. The main difference between the two structures arises from the fact that in this new structure the image and the scanner have different optical paths leading to an increase in the photocurrent when the scanning beam is incident on a region illuminated on the image side of the sensor, while a decreasing in the photocurrent was observed in the single junction LSP. The results show that the structure can be successfully used as an image sensor even though some optimization is needed to enhance the performance of the device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZnO:Al/p (SiC:H)/i (Si:H)/n (SiC:H) large area image and colour sensor are analysed. Carrier transport and collection efficiency are investigated from dark and illuminated current-voltage (I-V) dependence and spectral response measurements under different optical and electrical bias conditions. Results show that the carrier collection depends on the optical bias and on the applied voltage. By changing the electrical bias around the open circuit voltage it is possible to filter the absorption at a given wavelength and so to tune the spectral sensitivity of the device. Transport and optical modelling give insight into the internal physical process and explain the bias control of the spectral response and the image and colour sensing properties of the devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper discusses the difficulties in judging the quality of scientific manuscripts and describes some common pitfalls that should be avoided when preparing a paper for submission to a peer-reviewed journal. Peer review is an imperfect system, with less than optimal reliability and uncertain validity. However, as it is likely that it will remain as the principal process of screening papers for publication, authors should avoid some common mistakes when preparing a report based on empirical findings of human research. Among these are: excessively long abstracts, extensive use of abbreviations, failure to report results of parsimonious data analyses, and misinterpretation of statistical associations identified in observational studies as causal. Another common problem in many manuscripts is their excessive length, which makes them more difficult to be evaluated or read by the intended readers, if published. The evaluation of papers after their publication with a view towards their inclusion in a systematic review is also discussed. The limitations of the impact factor as a criterion to judge the quality of a paper are reviewed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the photodiode capacitance dependence on imposed light and applied voltage using different devices. The first device is a double amorphous silicon pin-pin photodiode; the second one a crystalline pin diode and the last one a single pin amorphous silicon diode. Double amorphous silicon diodes can be used as (de)multiplexer devices for optical communications. For short range applications, using plastic optical fibres, the WDM (wavelength-division multiplexing) technique can be used in the visible light range to encode multiple signals. Experimental results consist on measurements of the photodiode capacitance under different conditions of imposed light and applied voltage. The relation between the capacitive effects of the double diode and the quality of the semiconductor internal junction will be analysed. The dynamics of charge accumulations will be measured when the photodiode is illuminated by a pulsed monochromatic light.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multilayered heterostructures based on embedded a-Si:H and a-SiC:H p-i-n filters are analyzed from differential voltage design perspective using short- and long-pass filters. The transfer functions characteristics are presented. A numerical simulation is presented to explain the filtering properties of the photonic devices. Several monochromatic pulsed lights, separately (input channels) or in a polychromatic mixture (multiplexed signal) at different bit rates, illuminated the device. Steady-state optical bias is superimposed from the front and the back side. Results show that depending on the wavelength of the external background and impinging side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. Particular attention is given to the amplification coefficient weights, which allow to take into account the wavelength background effects when a band or frequency needs to be filtered or the gate switch, in which optical active filter gates are used to select and filter input signals to specific output ports in wavelength division multiplexing (WDM) communication systems. This nonlinearity provides the possibility for selective removal or addition of wavelengths. A truth table of an encoder that performs 8-to-1 MUX function exemplifies the optoelectronic conversion.