826 resultados para "quality assurance
Resumo:
The aim of this paper was to assess the Projeto UNI (Kellogg Foundation) in one of the Mental Health Centers (ARE) of Botucatu, SP, Brazil. We analysed 20% of the charts and the number of patients seen by psychiatrists and other mental health professionals before and after. Our results showed that: 1) the service users were mainly of neurotic patients (anxious, dysthymiacs, ICD-9 V code), followed by psychotics (schizophrenics, affectives) and organics (epileptics, mental deficients, demented patients); 2) there were more treatment options after the Projeto UNI implementation and over 2,495 group consultations were made in one year (as opposed to 90 in the year prior the project); 3) medical and nurse students are evaluating the program favourably; 4) there is a clear necessity of reassessing and changing some prescription practices: 43% of the patients were taking drug associations, there was an excessive use of benzodiazepines (54%) and low use of mood stabilizers (5%). There is also a need for more availability of depot neuroleptics, other antidepressants and better quality psychotropic drugs, and 5) there is a necessity of improving quality and quantity of charts information.
Resumo:
Two experiments of seed ageing of Eucalyptus grandis Hill ex Maiden were carried out at laboratory conditions. In the first experiment, two seed lots were classified in two square mesh screens (< 0.84 to ≥ 0.71 mm and < 0.71 mm to ≥ 0.59 mm), submitted to 42 °C and 100% relative humidity, for 0, 8, 12, 24, and 32 hours of stress treatments. Seed germination tests were done with just aged seeds. The results showed that the stress period was not sufficient for ageing the seeds. In the second experiment, the best quality seed lot was separated in the same two sizes. The seeds were submitted under the same stress conditions of the first experiment but for 0, 48, 72, and 96 hours. The germination test was done right after the seeds were taken from the stress conditions, and with stored seeds at dry chamber (2 weeks and 26 months). It was concluded that both seed sizes reached 30% of moisture content under 72 hours of ageing conditions and showed significant germination losses when compared with seeds without ageing (control), as the moist seeds as the stored ones at dry chamber, for both 2 weeks and 26 months.
Resumo:
The designs of filters made by granular material or textile are mainly based on empirical or semi empirical retention criteria according to Terzaghi proposal, which compares particle diameter of the soil base with the filter porous spaces. Silveira in 1965, proposed one rational design retention criteria based on the probability of a particle from the soil base, carried by one dimensional flow, be restrained by the porous of the filter while trying to pass through its thickness. This new innovating theory, besides of being very simple, it is not frequently used for granular filters since the necessary parameters for the design has to be determine for each natural material. However, for textile this problem no longer exists because it has quality control during manufacturing and the necessary characteristics properties of the product are specify in the product catalog. This work presents one adaptation of the Silveira theory for textile filters and the step-by-step procedure for the determination of the characteristics properties of the textile products necessary for the design. This new procedure permits the determination of the confiability level of retention that one specific particle diameter form the soil base has for one specified textile. One complete example is presented to demonstrate the simplicity of the method proposed and how the textile characteristics are obtained.
Resumo:
The use of the Internet as a means of ensuring greater visibility for products, services and information offered by companies is gaining strength in recent decades. However, it is known that to ensure satisfaction and subsequent virtual customer loyalty, it is necessary to guarantee the quality of the websites, allowing indiscriminate access regardless of the resources used, as well as rapid responses to possible requests. In order to assist this process, this paper presents a set of guidelines for the development of websites having quality characteristics, efficiency and portability as per ISO 9126 norms. An observational analysis of e-commerce websites was done which showed that they are inadequate as to the proposed guidelines, making them difficult to access available content. Therefore, the adoption of the proposed guidelines can greatly contribute to increasing the quality of websites and, consequently, enable quick and effective access regardless of the resources used.
Resumo:
Polymorphism can cause quality deviations during the production of medicines and can influence their effectiveness. Therefore, an understanding of this phenomenon and its implications opens a wide field of possibilities to be explored in the pharmaceutical field, including the emergence of new paradigms and tools for the quality assurance of medicines. This paper presents an introduction to basic aspects of the polymorphism phenomenon and its implications for the production and control of medicines, with emphasis on drug polymorphs.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
Pós-graduação em Alimentos e Nutrição - FCFAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Almost forty years computed tomography (CT) has been one of the most powerful tools in diagnostic imaging. However, this modality delivers relatively high doses to their patients. It is known that the inappropriate use and unnecessary radiation may be associated with a significant risk of cancer, especially in pediatric patients. Moreover, the quality assurance in CT, provided and required by Portaria 453/98 and the guide of the RE 1016/05, ensures that the images generated by computer tomography provide reliable diagnostic information with doses as low as reasonably achievable. This research aimed to make the quality control (QC) of CT equipment; establish a better relationship between dose and noise on the image to protocols of skull CT according to the study of optimization proposed in 2005 by Daros; and assess the dose distribution in different cranial organs for protocols of adult and pediatric use in the routine of the Department of Diagnostic Imaging of HCFMB-UNESP. The equipment used for testing QC, optimization and dosimetry was a third generation tomograph GE Sytec 3000i
Resumo:
Currently, with the competitiveness that is seen in the market, it is crucial to the success of the business, develop new strategies to keep and win new customer preference. To ensure the success of a particular service or product, the secret is to continually meet the wishes and demands of the customers, which are the key parts of the business, through innovation, variety and quality assurance. To achieve this goal managers should be aware of all types of process that exist in the company, as they are primarily responsible and interested by quality service, customer satisfaction and consequently, generating favorable financial results. A tool used to ensure good results to business is the Quality Function Deployment (QFD) that seeks to hear and interpret customers requirements and turn them into essential features for a project
Resumo:
Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected
Resumo:
The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)