997 resultados para Conformational study of filaments


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrogel polymers are used for the manufacture of soft (or disposable) contact lenses worldwide today, but have a tendency to dehydrate on the eye. In vitro methods that can probe the potential for a given hydrogel polymer to dehydrate in vivo are much sought after. Nuclear magnetic resonance (NMR) has been shown to be effective in characterising water mobility and binding in similar systems (Barbieri, Quaglia et al., 1998, Larsen, Huff et al., 1990, Peschier, Bouwstra et al., 1993), predominantly through measurement of the spin-lattice relaxation time (T1), the spinspin relaxation time (T2) and the water diffusion coefficient (D). The aim of this work was to use NMR to quantify the molecular behaviour of water in a series of commercially available contact lens hydrogels, and relate these measurements to the binding and mobility of the water, and ultimately the potential for the hydrogel to dehydrate. As a preliminary study, in vitro evaporation rates were measured for a set of commercial contact lens hydrogels. Following this, comprehensive measurement of the temperature and water content dependencies of T1, T2 and D was performed for a series of commercial hydrogels that spanned the spectrum of equilibrium water content (EWC) and common compositions of contact lenses that are manufactured today. To quantify material differences, the data were then modelled based on theory that had been used for similar systems in the literature (Walker, Balmer et al., 1989, Hills, Takacs et al., 1989). The differences were related to differences in water binding and mobility. The evaporative results suggested that the EWC of the material was important in determining a material's potential to dehydrate in this way. Similarly, the NMR water self-diffusion coefficient was also found to be largely (if not wholly) determined by the WC. A specific binding model confirmed that the we was the dominant factor in determining the diffusive behaviour, but also suggested that subtle differences existed between the materials used, based on their equilibrium we (EWC). However, an alternative modified free volume model suggested that only the current water content of the material was important in determining the diffusive behaviour, and not the equilibrium water content. It was shown that T2 relaxation was dominated by chemical exchange between water and exchangeable polymer protons for materials that contained exchangeable polymer protons. The data was analysed using a proton exchange model, and the results were again reasonably correlated with EWC. Specifically, it was found that the average water mobility increased with increasing EWe approaching that of free water. The T1 relaxation was also shown to be reasonably well described by the same model. The main conclusion that can be drawn from this work is that the hydrogel EWe is an important parameter, which largely determines the behaviour of water in the gel. Higher EWe results in a hydrogel with water that behaves more like bulk water on average, or is less strongly 'bound' on average, compared with a lower EWe material. Based on the set of materials used, significant differences due to composition (for materials of the same or similar water content) could not be found. Similar studies could be used in the future to highlight hydrogels that deviate significantly from this 'average' behaviour, and may therefore have the least/greatest potential to dehydrate on the eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Micropolar and RNG-based modelling of industrially relevant boundary layer and recirculating swirling flows is described. Both models contain a number of adjustable parameters and auxiliary conditions that must be either modelled or experimentally determined, and the effects of varying these on the resulting flow solutions is quantified. To these ends, the behaviour of the micropolar model for self-similar flow over a surface that is both stretching and transpiring is explored in depth. The simplified governing equations permit both analytic and numerical approaches to be adopted, and a number of closed form solutions (both exact and approximate) are obtained using perturbation and order of magnitude analyses. Results are compared with the corresponding Newtonian flow solution in order to highlight the differences between the micropolar and classical models, and significant new insights into the behaviour of the micropolar model are revealed for this flow. The behaviour of the RNG-bas based models for swirling flow with vortex breakdown zones is explored in depth via computational modelling of two experimental data sets and an idealised breakdown flow configuration. Meticulous modeling of upstream auxillary conditions is required to correctly assess the behavior of the models studied in this work. The novel concept of using the results to infer the role of turbulence in the onset and topology of the breakdown zone is employed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Professional coaching is a rapidly expanding field with interdisciplinary roots and broad application. However, despite abundant prescriptive literature, research into the process of coaching, and especially life coaching, is minimal. Similarly, although learning is inherently recognised in the process of coaching, and coaching is increasingly being recognised as a means of enhancing teaching and learning, the process of learning in coaching is little understood, and learning theory makes up only a small part of the evidence-based coaching literature. In this grounded theory study of life coaches and their clients, the process of learning in life coaching across a range of coaching models is examined and explained. The findings demonstrate how learning in life coaching emerged as a process of discovering, applying and integrating self-knowledge, which culminated in the development of self. This process occurred through eight key coaching processes shared between coaches and clients and combined a multitude of learning theory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human-technology nexus is a strong focus of Information Systems (IS) research; however, very few studies have explored this phenomenon in anaesthesia. Anaesthesia has a long history of adoption of technological artifacts, ranging from early apparatus to present-day information systems such as electronic monitoring and pulse oximetry. This prevalence of technology in modern anaesthesia and the rich human-technology relationship provides a fertile empirical setting for IS research. This study employed a grounded theory approach that began with a broad initial guiding question and, through simultaneous data collection and analysis, uncovered a core category of technology appropriation. This emergent basic social process captures a central activity of anaesthestists and is supported by three major concepts: knowledge-directed medicine, complementary artifacts and culture of anaesthesia. The outcomes of this study are: (1) a substantive theory that integrates the aforementioned concepts and pertains to the research setting of anaesthesia and (2) a formal theory, which further develops the core category of appropriation from anaesthesia-specific to a broader, more general perspective. These outcomes fulfill the objective of a grounded theory study, being the formation of theory that describes and explains observed patterns in the empirical field. In generalizing the notion of appropriation, the formal theory is developed using the theories of Karl Marx. This Marxian model of technology appropriation is a three-tiered theoretical lens that examines appropriation behaviours at a highly abstract level, connecting the stages of natural, species and social being to the transition of a technology-as-artifact to a technology-in-use via the processes of perception, orientation and realization. The contributions of this research are two-fold: (1) the substantive model contributes to practice by providing a model that describes and explains the human-technology nexus in anaesthesia, and thereby offers potential predictive capabilities for designers and administrators to optimize future appropriations of new anaesthetic technological artifacts; and (2) the formal model contributes to research by drawing attention to the philosophical foundations of appropriation in the work of Marx, and subsequently expanding the current understanding of contemporary IS theories of adoption and appropriation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Simulation study of a custom power park (CPP) is presented. It is assumed that the park contains unbalanced and nonlinear loads in addition to a sensitive load. Two different types of compensators are used separately to protect the sensitive load against unbalance and distortion caused by the other loads. It has been shown that a shunt compensator can regulate the voltage of the CPP bus, whereas the series compensator can only regulate the sensitive load terminal voltage. Additional issues such as the load transfer through a static transfer switch, detection of sag/fault etc. are also discussed. The concepts are validated through PSCAD/EMTDC simulation studies on a sample distribution system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This methodological paper reports on the development and validation of a work sampling instrument and data collection processes to conduct a national study of nurse practitioners’ work patterns. ---------- Design: Published work sampling instruments provided the basis for development and validation of a tool for use in a national study of nurse practitioner work activities across diverse contextual and clinical service models. Steps taken in the approach included design of a nurse practitioner-specific data collection tool and development of an innovative web-based program to train and establish inter rater reliability of a team of data collectors who were geographically dispersed across metropolitan, rural and remote health care settings. ---------- Setting: The study is part of a large funded study into nurse practitioner service. The Australian Nurse Practitioner Study is a national study phased over three years and was designed to provide essential information for Australian health service planners, regulators and consumer groups on the profile, process and outcome of nurse practitioner service. ---------- Results: The outcome if this phase of the study is empirically tested instruments, process and training materials for use in an international context by investigators interested in conducting a national study of nurse practitioner work practices. ---------- Conclusion: Development and preparation of a new approach to describing nurse practitioner practices using work sampling methods provides the groundwork for international collaboration in evaluation of nurse practitioner service.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A hip fracture causes permanent changes to life style for older people. Further, two important mortality indicators found post operatively for this group include, the time until surgery after fracture, and pre-operative health status prior to surgery, yet no research is available investigating relationships between time to surgery and health status. The researchers aimed to establish the health status risks for patients aged over 65 years with a non-pathological hip fracture to guide nursing care interventions. A prospective cohort design was used to investigate relationships between time to surgery and measures on pre-operative health status indicators including, skin integrity risk, vigor, mental state, bowel function and continence. Twenty-nine patients with a mean age in years of 81.93 (SD,9.49), were recruited. The mean number of hours from time 1 assessment to surgery was 52.72 (SD,58.35) and the range was 1 hour to 219 hours. At Time 2, the mean scores of vigor and skin integrity risk were significantly higher, indicating poorer health status. A change in health status occurred but possibly due to the small sample size it was difficult to relate this result to time. However the results informed preoperative care prior to surgery, for this group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Australian climate, soils and agricultural management practices are significantly different from those of the northern hemisphere nations. Consequently, experimental data on greenhouse gas production from European and North American agricultural soils and its interpretation are unlikely to be directly applicable to Australian systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gel dosimeters are of increasing interest in the field of radiation oncology as the only truly three-dimensional integrating radiation dosimeter. There are a range of ferrous-sulphate and polymer gel dosimeters. To be of use, they must be water-equivalent. On their own, this relates to their radiological properties as determined by their composition. In the context of calibration of gel dosimeters, there is the added complexity of the calibration geometry; the presence of containment vessels may influence the dose absorbed. Five such methods of calibration are modelled here using the Monte Carlo method. It is found that the Fricke gel best matches water for most of the calibration methods, and that the best calibration method involves the use of a large tub into which multiple fields of different dose are directed. The least accurate calibration method involves the use of a long test tube along which a depth dose curve yields multiple calibration points.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gel dosimeters are of increasing interest in the field of radiation oncology as the only truly three-dimensional integrating radiation dosimeter. There are a range of ferrous-sulphate and polymer gel dosimeters. To be of use, they must be water-equivalent. On their own, this relates to their radiological properties as determined by their composition. In the context of calibration of gel dosimeters, there is the added complexity of the calibration geometry; the presence of containment vessels may influence the dose absorbed. Five such methods of calibration are modelled here using the Monte Carlo method. It is found that the Fricke gel best matches water for most of the calibration methods, and that the best calibration method involves the use of a large tub into which multiple fields of different dose are directed. The least accurate calibration method involves the use of a long test tube along which a depth dose curve yields multiple calibration points.