1000 resultados para virtual microscopy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 26-hour English reading comprehension course was taught to two groups of second year Finnish Pharmacy students: a virtual group (33 students) and a teacher-taught group (25 students). The aims of the teaching experiment were to find out: 1.What has to be taken into account when teaching English reading comprehension to students of pharmacy via the Internet and using TopClass? 2. How will the learning outcomes of the virtual group and the control group differ? 3. How will the students and the Department of Pharmacy respond to the different and new method, i.e. the virtual teaching method? 4. Will it be possible to test English reading comprehension learning material using the groupware tool TopClass? The virtual exercises were written within the Internet authoring environment, TopClass. The virtual group was given the reading material and grammar booklet on paper, but they did the reading comprehension tasks (written by the teacher), autonomously via the Internet. The control group was taught by the same teacher in 12 2-hour sessions, while the virtual group could work independently within the given six weeks. Both groups studied the same material: ten pharmaceutical articles with reading comprehension tasks as well as grammar and vocabulary exercises. Both groups took the same final test. Students in both groups were asked to evaluate the course using a 1 to 5 rating scale and they were also asked to assess their respective courses verbally. A detailed analysis of the different aspects of the student evaluation is given. Conclusions: 1.The virtual students learned pharmaceutical English relatively well but not significantly better than the classroom students 2. The overall student satisfaction in the virtual pharmacy English reading comprehension group was found to be higher than that in the teacher-taught control group. 3. Virtual learning is easier for linguistically more able students; less able students need more time with the teacher. 4. The sample in this study is rather small, but it is a pioneering study. 5. The Department of Pharmacy in the University of Helsinki wishes to incorporate virtual English reading comprehension teaching in its curriculum. 6. The sophisticated and versatile TopClass system is relatively easy for a traditional teacher and quite easy for the students to learn. It can be used e.g. for automatic checking of routine answers and document transfer, which both lighten the workloads of both parties. It is especially convenient for teaching reading comprehension. Key words: English reading comprehension, teacher-taught class, virtual class, attitudes of students, learning outcomes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

My thesis concerns the notion of existence as an encounter, as developed in the philosophy of Gilles Deleuze (1925 1995). What this denotes is a critical stance towards a major current in Western philosophical tradition which Deleuze nominates as representational thinking. Such thinking strives to provide a stable ground for identities by appealing to transcendent structures behind the apparent reality and explaining the manifest diversity of the given by such notions as essence, idea, God, or totality of the world. In contrast to this, Deleuze states that abstractions such as these do not explain anything, but rather that they need to be explained. Yet, Deleuze does not appeal merely to the given. He sees that one must posit a genetic element that accounts for experience, and this element must not be naïvely traced from the empirical. Deleuze nominates his philosophy as transcendental empiricism and he seeks to bring together the approaches of both empiricism and transcendental philosophy. In chapter one I look into the motivations of Deleuze s transcendental empiricism and analyse it as an encounter between Deleuze s readings of David Hume and Immanuel Kant. This encounter regards, first of all, the question of subjectivity and results in a conception of identity as non-essential process. A pre-given concept of identity does not explain the nature of things, but the concept itself must be explained. From this point of view, the process of individualisation must become the central concern. In chapter two I discuss Deleuze s concept of the affect as the basis of identity and his affiliation with the theories of Gilbert Simondon and Jakob von Uexküll. From this basis develops a morphogenetic theory of individuation-as-process. In analysing such a process of individuation, the modal category of the virtual becomes of great value, being an open, indeterminate charge of potentiality. As the virtual concerns becoming or the continuous process of actualisation, then time, rather than space, will be the privileged field of consideration. Chapter three is devoted to the discussion of the temporal aspect of the virtual and difference-without-identity. The essentially temporal process of subjectification results in a conception of the subject as composition: an assemblage of heterogeneous elements. Therefore art and aesthetic experience is valued by Deleuze because they disclose the construct-like nature of subjectivity in the sensations they produce. Through the domain of the aesthetic the subject is immersed in the network of affectivity that is the material diversity of the world. Chapter four addresses a phenomenon displaying this diversified indentity: the simulacrum an identity that is not grounded in an essence. Developed on the basis of the simulacrum, a theory of identity as assemblage emerges in chapter five. As the problematic of simulacra concerns perhaps foremost the artistic presentation, I shall look into the identity of a work of art as assemblage. To take an example of a concrete artistic practice and to remain within the problematic of the simulacrum, I shall finally address the question of reproduction particularly in the case recorded music and its identity regarding the work of art. In conclusion, I propose that by overturning its initial representational schema, phonographic music addresses its own medium and turns it into an inscription of difference, exposing the listener to an encounter with the virtual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pin-on-disc machine was used to wear Al-Si alloy pins under dry conditions. Unmodified and modified binary alloys and commercial multi-component alloys were tested. The surfaces of the worn alloys were examined by scanning electron microscopy to identify distinct topographical features to aid elucidation of the mechanisms of wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light interception is a major factor influencing plant development and biomass production. Several methods have been proposed to determine this variable, but its calculation remains difficult in artificial environments with heterogeneous light. We propose a method that uses 3D virtual plant modelling and directional light characterisation to estimate light interception in highly heterogeneous light environments such as growth chambers and glasshouses. Intercepted light was estimated by coupling an architectural model and a light model for different genotypes of the rosette species Arabidopsis thaliana (L.) Heynh and a sunflower crop. The model was applied to plants of contrasting architectures, cultivated in isolation or in canopy, in natural or artificial environments, and under contrasting light conditions. The model gave satisfactory results when compared with observed data and enabled calculation of light interception in situations where direct measurements or classical methods were inefficient, such as young crops, isolated plants or artificial conditions. Furthermore, the model revealed that A. thaliana increased its light interception efficiency when shaded. To conclude, the method can be used to calculate intercepted light at organ, plant and plot levels, in natural and artificial environments, and should be useful in the investigation of genotype-environment interactions for plant architecture and light interception efficiency. This paper originates from a presentation at the 5th International Workshop on Functional–Structural Plant Models, Napier, New Zealand, November 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Corneal confocal microscopy is a novel diagnostic technique for the detection of nerve damage and repair in a range of peripheral neuropathies, in particular diabetic neuropathy. Normative reference values are required to enable clinical translation and wider use of this technique. We have therefore undertaken a multicenter collaboration to provide worldwide age-adjusted normative values of corneal nerve fiber parameters. RESEARCH DESIGN AND METHODS A total of 1,965 corneal nerve images from 343 healthy volunteers were pooled from six clinical academic centers. All subjects underwent examination with the Heidelberg Retina Tomograph corneal confocal microscope. Images of the central corneal subbasal nerve plexus were acquired by each center using a standard protocol and analyzed by three trained examiners using manual tracing and semiautomated software (CCMetrics). Age trends were established using simple linear regression, and normative corneal nerve fiber density (CNFD), corneal nerve fiber branch density (CNBD), corneal nerve fiber length (CNFL), and corneal nerve fiber tortuosity (CNFT) reference values were calculated using quantile regression analysis. RESULTS There was a significant linear age-dependent decrease in CNFD (-0.164 no./mm(2) per year for men, P < 0.01, and -0.161 no./mm(2) per year for women, P < 0.01). There was no change with age in CNBD (0.192 no./mm(2) per year for men, P = 0.26, and -0.050 no./mm(2) per year for women, P = 0.78). CNFL decreased in men (-0.045 mm/mm(2) per year, P = 0.07) and women (-0.060 mm/mm(2) per year, P = 0.02). CNFT increased with age in men (0.044 per year, P < 0.01) and women (0.046 per year, P < 0.01). Height, weight, and BMI did not influence the 5th percentile normative values for any corneal nerve parameter. CONCLUSIONS This study provides robust worldwide normative reference values for corneal nerve parameters to be used in research and clinical practice in the study of diabetic and other peripheral neuropathies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE This study determined if deficits in corneal nerve fiber length (CNFL) assessed using corneal confocal microscopy (CCM) can predict future onset of diabetic peripheral neuropathy (DPN). RESEARCH DESIGN AND METHODS CNFL and a range of other baseline measures were compared between 90 nonneuropathic patients with type 1 diabetes who did or did not develop DPN after 4 years. The receiver operator characteristic (ROC) curve was used to determine the capability of single and combined measures of neuropathy to predict DPN. RESULTS DPN developed in 16 participants (18%) after 4 years. Factors predictive of 4-year incident DPN were lower CNFL (P = 0.041); longer duration of diabetes (P = 0.002); higher triglycerides (P = 0.023); retinopathy (higher on the Early Treatment of Diabetic Retinopathy Study scale) (P = 0.008); nephropathy (higher albumin-to-creatinine ratio) (P = 0.001); higher neuropathy disability score (P = 0.037); lower cold sensation (P = 0.001) and cold pain (P = 0.027) thresholds; higher warm sensation (P = 0.008), warm pain (P = 0.024), and vibration (P = 0.003) thresholds; impaired monofilament response (P = 0.003); and slower peroneal (P = 0.013) and sural (P = 0.002) nerve conduction velocity. CCM could predict the 4-year incident DPN with 63% sensitivity and 74% specificity for a CNFL threshold cutoff of 14.1 mm/mm2 (area under ROC curve = 0.66, P = 0.041). Combining neuropathy measures did not improve predictive capability. CONCLUSIONS DPN can be predicted by various demographic, metabolic, and conventional neuropathy measures. The ability of CCM to predict DPN broadens the already impressive diagnostic capabilities of this novel ophthalmic marker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to analyze and facilitate collaborative design in a virtual learning environment (VLE). Discussions of virtual design in design education have typically focused on technological or communication issues, not on pedagogical issues. Yet in order to facilitate collaborative design, it is also necessary to address the pedagogical issues related to the virtual design process. In this study, the progressive inquiry model of collaborative designing was used to give a structural level of facilitation to students working in the VLE. According to this model, all aspects of inquiry, such as creating the design context, constructing a design idea, evaluating the idea, and searching for new information, can be shared in a design community. The study consists of three design projects: 1) designing clothes for premature babies, 2) designing conference bags for an international conference, and 3) designing tactile books for visually impaired children. These design projects constituted a continuum of design experiments, each of which highlighted certain perspectives on collaborative designing. The design experiments were organized so that the participants worked in design teams, both face-to-face and virtually. The first design experiment focused on peer collaboration among textile teacher students in the VLE. The second design experiment took into consideration end-users needs by using a participatory design approach. The third design experiment intensified computer-supported collaboration between students and domain experts. The virtual learning environments, in these design experiments, were designed to support knowledge-building pedagogy and progressive inquiry learning. These environments enabled a detailed recording of all computer-mediated interactions and data related to virtual designing. The data analysis was based on qualitative content analysis of design statements in the VLE. This study indicated four crucial issues concerning collaborative design in the VLE in craft and design education. Firstly, using the collaborative design process in craft and design education gives rise to special challenges of building learning communities, creating appropriate design tasks for them, and providing tools for collaborative activities. Secondly, the progressive inquiry model of collaborative designing can be used as a scaffold support for design thinking and for reflection on the design process. Thirdly, participation and distributed expertise can be facilitated by considering the key stakeholders who are related to the design task or design context, and getting them to participate in virtual designing. Fourthly, in the collaborative design process, it is important that team members create and improve visual and technical ideas together, not just agree or disagree about proposed ideas. Therefore, viewing the VLE as a medium for collaborative construction of the design objects appears crucial in order to understand and facilitate the complex processes in collaborative designing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report here that the structural origin of an easily reversible Ge15Te83Si2 glass can be a promising candidate for phase change random access memories. In situ Raman scattering studies on Ge15Te83Si2 sample, undertaken during the amorphous set and reset processes, indicate that the degree of disorder in the glass is reduced from off to set state. It is also found that the local structure of the sample under reset condition is similar to that in the amorphous off state. Electron microscopic studies on switched samples indicate the formation of nanometric sized particles of c-SiTe2 structure. ©2009 American Institute of Physics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim of this study was to determine alterations to the corneal subbasal nerve plexus (SNP) over four years using in vivo corneal confocal microscopy (IVCM) in participants with type 1 diabetes and to identify significant risk factors associated with these alterations. Methods A cohort of 108 individuals with type 1 diabetes and no evidence of peripheral neuropathy at enrollment underwent laser-scanning IVCM, ocular screening, and health and metabolic assessment at baseline and the examinations continued for four subsequent annual visits. At each annual visit, eight central corneal images of the SNP were selected and analyzed to quantify corneal nerve fiber density (CNFD), branch density (CNBD) and fiber length (CNFL). Linear mixed model approaches were fitted to examine the relationship between risk factors and corneal nerve parameters. Results A total of 96 participants completed the final visit and 91 participants completed all visits. No significant relationships were found between corneal nerve parameters and time, sex, duration of diabetes, smoking, alcohol consumption, blood pressure or BMI. However, CNFD was negatively associated with HbA1c (β=-0.76, P<0.01) and age (β=-0.13, P<0.01) and positively related to high density lipids (HDL) (β=2.01, P=0.03). Higher HbA1c (β=-1.58, P=0.04) and age (β=-0.23, P<0.01) also negatively impacted CNBD. CNFL was only affected by higher age (β=-0.06, P<0.01). Conclusions Glycemic control, HDL and age have significant effects on SNP structure. These findings highlight the importance of diabetic management to prevent corneal nerve damage as well as the capability of IVCM for monitoring subclinical alterations in the corneal SNP in diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Corneal innervation is increasingly used as a surrogate marker of human diabetic peripheral neuropathy (DPN) however its temporal relationship with the other microvascular complications of diabetes is not fully established. In this cross-sectional, observational study we aimed to assess whether neuropathy occurred in patients with type 1 diabetes, without retinopathy or microalbuminuria. Materials and Methods All participants underwent detailed assessment of peripheral neuropathy [neuropathy disability score (NDS), vibration perception threshold (VPT), peroneal motor nerve conduction velocity (PMNCV), sural sensory nerve conduction velocity (SSNCV) and in vivo corneal confocal microscopy (IVCCM)], retinopathy (digital fundus photography) and albuminuria status [albumin: creatinine ratio (ACR)]. Results 53 patients with Type 1 diabetes with (n=37) and without retinopathy (n=16) were compared to control subjects (n=27). SSNCV, corneal nerve fibre (CNFD) and branch (CNBD) density and length (CNFL) were reduced significantly (p<0.001) in diabetic patients without retinopathy compared to control subjects. Furthermore, CNFD, CNBD and CNFL were also significantly (p<0.001) reduced in diabetic patients without microalbuminuria (n=39), compared to control subjects. Greater neuropathic severity was associated with established retinopathy and microalbuminuria. Conclusions IVCCM detects early small fibre damage in the absence of retinopathy or microalbuminuria in patients with Type 1 diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Quantitative assessment of small fiber damage is key to the early diagnosis and assessment of progression or regression of diabetic sensorimotor polyneuropathy (DSPN). Intraepidermal nerve fiber density (IENFD) is the current gold standard, but corneal confocal microscopy (CCM), an in vivo ophthalmic imaging modality, has the potential to be a noninvasive and objective image biomarker for identifying small fiber damage. The purpose of this study was to determine the diagnostic performance of CCM and IENFD by using the current guidelines as the reference standard. RESEARCH DESIGN AND METHODS Eighty-nine subjects (26 control subjects and 63 patients with type 1 diabetes), with and without DSPN, underwent a detailed assessment of neuropathy, including CCM and skin biopsy. RESULTS Manual and automated corneal nerve fiber density (CNFD) (P < 0.0001), branch density (CNBD) (P < 0.0001) and length (CNFL) (P < 0.0001), and IENFD (P < 0.001) were significantly reduced in patients with diabetes with DSPN compared with control subjects. The area under the receiver operating characteristic curve for identifying DSPN was 0.82 for manual CNFD, 0.80 for automated CNFD, and 0.66 for IENFD, which did not differ significantly (P = 0.14). CONCLUSIONS This study shows comparable diagnostic efficiency between CCM and IENFD, providing further support for the clinical utility of CCM as a surrogate end point for DSPN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In vivo corneal confocal microscopy (CCM) is increasingly used as a surrogate endpoint in studies of diabetic polyneuropathy (DPN). However, it is not clear whether imaging the central cornea provides optimal diagnostic utility for DPN. Therefore, we compared nerve morphology in the central cornea and the inferior whorl, a more distal and densely innervated area located inferior and nasal to the central cornea. METHODS: A total of 53 subjects with type 1/type 2 diabetes and 15 age-matched control subjects underwent detailed assessment of neuropathic symptoms (NPS), deficits (neuropathy disability score [NDS]), quantitative sensory testing (vibration perception threshold [VPT], cold and warm threshold [CT/WT], and cold- and heat-induced pain [CIP/HIP]), and electrophysiology (sural and peroneal nerve conduction velocity [SSNCV/PMNCV], and sural and peroneal nerve amplitude [SSNA/PMNA]) to diagnose patients with (DPN+) and without (DPN-) neuropathy. Corneal nerve fiber density (CNFD) and length (CNFL) in the central cornea, and inferior whorl length (IWL) were quantified. RESULTS: Comparing control subjects to DPN- and DPN+ patients, there was a significant increase in NDS (0 vs. 2.6 ± 2.3 vs. 3.3 ± 2.7, P < 0.01), VPT (V; 5.4 ± 3.0 vs. 10.6 ± 10.3 vs. 17.7 ± 11.8, P < 0.01), WT (°C; 37.7 ± 3.5 vs. 39.1 ± 5.1 vs. 41.7 ± 4.7, P < 0.05), and a significant decrease in SSNCV (m/s; 50.2 ± 5.4 vs. 48.4 ± 5.0 vs. 39.5 ± 10.6, P < 0.05), CNFD (fibers/mm2; 37.8 ± 4.9 vs. 29.7 ± 7.7 vs. 27.1 ± 9.9, P < 0.01), CNFL (mm/mm2; 27.5 ± 3.6 vs. 24.4 ± 7.8 vs. 20.7 ± 7.1, P < 0.01), and IWL (mm/mm2; 35.1 ± 6.5 vs. 26.2 ± 10.5 vs. 23.6 ± 11.4, P < 0.05). For the diagnosis of DPN, CNFD, CNFL, and IWL achieved an area under the curve (AUC) of 0.75, 0.74, and 0.70, respectively, and a combination of IWL-CNFD achieved an AUC of 0.76. CONCLUSIONS: The parameters of CNFD, CNFL, and IWL have a comparable ability to diagnose patients with DPN. However, IWL detects an abnormality even in patients without DPN. Combining IWL with CNFD may improve the diagnostic performance of CCM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural defects of three chloritoid minerals from distinet geologic melieu have been investigated by high resolution electron microscopy. X-ray powder and electron diffraction patterns indicate that the chloritoid from one geological source (A) is2M 1+2M2 monoclinic variant while those from another geological source (B) are 2M 2 monoclinic variants. In a typical one-dimensional lattice image of a crystal from sourceA, the 2M 2 matrix is broken by insertion of triclinic inter-growths. Another crystal with the 2M 2 matrix showed single, triple, quadruple and quintuple layers displaying an unusually high degree of disorder. Lattice images of 2M 2 monoclinic variants from sourceB yielded more homogeneous micrographs. The important finding from the present studies is that the chloritoid from sourceA is a severely disordered low-temperature intermediate phase in the conversion of the triclinic chloritoid to the high-temperature ordered monoclinic variants of sourceB. Severely disordered chloritoids, marking the beginning of low grade metamorphism, are generated as intermediates between the state of complete disordered arrangement towards the end of low grade metamorphism within the narrow stability range of 400°–500°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Examination of the structure of worn surfaces has shown that the wear of LM13 and LM13-graphite particulate composite is controlled by the nature and extent of subsurface deformation. The addition of graphite influences the wear characteristics by affecting the plastically deformed zone. The possible mechanisms of wear are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To determine the association between conjunctival goblet cell density (GCD) assessed using in vivo laser scanning confocal microscopy and conjunctival impression cytology in a healthy population. Methods Ninety (90) healthy participants undertook a validated 5-item dry eye questionnaire, non-invasive tear film break-up time measurement, ocular surface fluorescein staining and phenol red thread test. These tests where undertaken to diagnose and exclude participants with dry eye. The nasal bulbar conjunctiva was imaged using laser scanning confocal microscopy (LSCM). Conjunctival impression cytology (CIC) was performed in the same region a few minutes later. Conjunctival goblet cell density was calculated as cells/mm2. Results There was a strong positive correlation of conjunctival GCD between LSCM and CIC (ρ = 0.66). Conjunctival goblet cell density was 475 ± 41 cells/mm2 and 466 ± 51 cells/mm2 measured by LSCM and CIC, respectively. Conclusions The strong association between in vivo and in vitro cellular analysis for measuring conjunctival GCD suggests that the more invasive CIC can be replaced by the less invasive LSCM in research and clinical practice.