1000 resultados para tuber quality


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews the literature for lowering of dose to paediatric patients through use of exposure factors and additional filtration. Dose reference levels set by The International Commission on Radiological Protection (ICRP) will be considered. Guidance was put in place in 1996 requires updating to come into line with modern imaging equipment. There is a wide range of literature that specifies that grids should not be used on paediatric patients. Although much of the literature advocates additional filtration, contrasting views on the relative benefits of using aluminium or copper filtration, and their effects on dose reduction and image quality can vary. Changing kVp and mAs has an effect on the dose to the patient and image quality. Collimation protects adjacent structures whilst reducing scattered radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Todas as crianças, independentemente das suas necessidades, deveriam ter acesso a uma educação de qualidade e a serem incluídas nas suas famílias e comunidades. Esta afirmação inclui as crianças mais vulneráveis, em particular as crianças com dificuldades intelectuais e multideficiência. Os resultados da investigação sobre a educação de crianças com dificuldades intelectuais e multideficiência ainda não produziram até ao momento informação suficiente que possa ser usada para desenvolver indicadores de qualidade para a avaliação das práticas e dos serviços. A investigação nesta área é limitada por constrangimentos éticos, dificuldades na determinação de amostras e desafios metodológicos, sendo reduzido o número de estudos capaz de produzir a informação necessária. Este artigo tem como objetivo discutir fatores que contribuam para a qualidade do envolvimento de crianças com dificuldades intelectuais e multideficiência em atividades educativas, com base na experiência das autoras e na informação disponível que tem sido publicada sobre este assunto. Com base nesta discussão é sugerido um conjunto de indicadores que poderão ajudar os profissionais a dirigir as suas observações para a qualidade da oferta educativa e para aspetos significativos dos desempenhos das crianças quando envolvidas em atividades curriculares.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Journal of Business, Vol. 78 Issue 3, p1049-1072

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To develop and validate a psychometric scale for assessing image quality for chest radiographs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo de síntese sobre alguns dos mais conceituados Especialistas da Qualidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

57Th EOQ Congress, Quality Renaissance - Co-creating a Viable Future"

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring the quality of a b-learning environment is critical to determine the success of a b-learning course. There are a lot of materials related to the quality process, namely different approaches and perspectives but none of them is specific of the product of a b-learning context. In this paper we identify the indicators that should be analyzed in order to determine the quality of a b-learning course, since its success reflect not only the student’s perception, but also what should be taken into account. B-Learning environments are relatively new and combine educational characteristics with technological elements that support the learning process and the training delivery. Our main objective is to know what a high quality b-learning environment is in students’’ perception and what are the main quality dimensions of these courses, in the perspective of the products and services offered. After a literature review concerning the quality process and in particular the b-learning quality field, a structure that provides the main elements that should be evaluated by students when we are measuring the quality and the success of b-learning product/services was created. The structure obtained was applied to a case study of the Polytechnic Institute of Oporto. Results presented will help institutions to deliver services with more quality and improve their long-term competitiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical content of administrative databases includes, among others, patient demographic characteristics, and codes for diagnoses and procedures. The data in these databases is standardized, clearly defined, readily available, less expensive than collected by other means, and normally covers hospitalizations in entire geographic areas. Although with some limitations, this data is often used to evaluate the quality of healthcare. Under these circumstances, the quality of the data, for instance, errors, or it completeness, is of central importance and should never be ignored. Both the minimization of data quality problems and a deep knowledge about this data (e.g., how to select a patient group) are important for users in order to trust and to correctly interpret results. In this paper we present, discuss and give some recommendations for some problems found in these administrative databases. We also present a simple tool that can be used to screen the quality of data through the use of domain specific data quality indicators. These indicators can significantly contribute to better data, to give steps towards a continuous increase of data quality and, certainly, to better informed decision-making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ventilation efficiency concept is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the building spaces. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by Computational fluid dynamics (CFD). Were compared the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE), the two indicators most internationally accepted. The main results from this work shows that the values of the numerical simulations are in good agreement with experimental measurements and also, that the solutions to be adopted for maximizing the ventilation efficiency should be the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spent coffee grounds (SCG) are usually disposed as common garbage, without specific reuse strategies implemented so far. Due to its recognised richness in bioactive compounds, the effect of SCG on lettuce’s macro- and micro-elements was assessed to define its effectiveness for agro industrial reuse. A greenhouse pot experiment was conducted with different amounts of fresh and composted spent coffee, and potassium, magnesium, phosphorous, calcium, sodium, iron, manganese, zinc and copper were analysed. A progressive decrease on all lettuce mineral elements was verified with the increase of fresh spent coffee, except for potassium. In opposition, an increment of lettuce’s essential macro-elements was verified when low amounts of composted spent coffee were applied (5%, v/v), increasing potassium content by 40%, manganese by 30%, magnesium by 20%, and sodium by 10%, of nutritional relevance This practical approach offers an alternative reuse for this by-product, extendable to other crops, providing value-added vegetable products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to optimize the water quality monitoring of a polluted watercourse (Leça River, Portugal) through the principal component analysis (PCA) and cluster analysis (CA). These statistical methodologies were applied to physicochemical, bacteriological and ecotoxicological data (with the marine bacterium Vibrio fischeri and the green alga Chlorella vulgaris) obtained with the analysis of water samples monthly collected at seven monitoring sites and during five campaigns (February, May, June, August, and September 2006). The results of some variables were assigned to water quality classes according to national guidelines. Chemical and bacteriological quality data led to classify Leça River water quality as “bad” or “very bad”. PCA and CA identified monitoring sites with similar pollution pattern, giving to site 1 (located in the upstream stretch of the river) a distinct feature from all other sampling sites downstream. Ecotoxicity results corroborated this classification thus revealing differences in space and time. The present study includes not only physical, chemical and bacteriological but also ecotoxicological parameters, which broadens new perspectives in river water characterization. Moreover, the application of PCA and CA is very useful to optimize water quality monitoring networks, defining the minimum number of sites and their location. Thus, these tools can support appropriate management decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fresh-cut vegetables are a successful convenient healthy food. Nowadays, the presence of new varieties of minimally processed vegetables in the market is common in response to the consumers demand for new flavours and high quality products. Within the most recent fresh-cut products are the aromatic herbs. In this work, the objective was to evaluate the nutritional quality and stability of four fresh-cut aromatic herbs. Several physicochemical quality characteristics (colour, pH, total soluble solids, and total titratable acidity) were monitored in fresh-cut chives, coriander, spearmint and parsley leaves, stored under refrigeration (3 ± 1 ºC) during 10 days. Their nutritional composition was determined, including mineral composition (phosphorous, potassium, sodium, calcium, magnesium, iron, zinc, manganese and copper) and fat- and water-soluble vitamin contents. Total soluble phenolics, flavonoids and the antioxidant capacity were determined by spectrophotometric methods. The aromatic herbs kept their fresh appearance during the storage, maintaining their colour throughout shelf-life. Their macronutrient composition and mineral content were stable during storage. Coriander had the highest mineral and fatsoluble vitamin content, while spearmint showed the best scores in the phenolic, flavonoid and antioxidant capacity assays. Vitamins and antioxidant capacity showed some variation during storage, with a differential behaviour of each compound according to the sample.