958 resultados para irregularities in proceeding by plaintiff


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different kinds of modifiers and coatings on the integrated platform of transversely heated graphite atomizer (THGA) have been tested for the simultaneous determination of two group of elements: the first, the more volatile, formed by arsenic, bismuth, lead, antimony and selenium; the second, the less volatile, formed by cobalt, chromium, cupper, iron and manganese in milk by electrothermal atomic absorption spectrometry. Different Rh-modifiers were studied, such as Rh-coated platforms (Rh), carbide plus rhodium coated platforms (W-Rh, Zr-Rh), carbide-coated platforms (W and Zr) with co-injection of RhCl3, solutions and uncoated platforms with injection of solutions of Pd(NO3)(2), Mg(NO3)(2), and RhCl3. Milk samples were diluted 1:10 in 1.0% HNO3 and injected into the tube. The mass of modifier deposited and co-injected in the tube and the use of end capped tubes were also evaluated in order to improve the electrothermal behavior of analytes. Integrated platform pretreated with W plus co-injection RhCl3 for first group and pretreated with W-Rh for second group were elected. For 20 mu L injected samples the analytical curves in the 5.0-20.0 mu g L-1 concentration range have good linear correlation coefficients (r > 0.998). Relative standard deviations (n = 12) are < 6% and the calculated characteristic masses are between 5 pg and 62 pg.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim of the study was to evaluate the influence of an extra corporal perfusion (cardiopulmonary bypass operation - cpb) on activation and biodistribution of Tc-99m labelled granulocytes in pigs with and without inhibition of the granulocytes by a leukocyte inhibition module (LIM). The cpb is often related to an activation of granulocytes resulting in an inflammatory answer. The biological mechanisms are unsolved yet. First trials of our group showed that LIM may inhibit the activation of neutrophils and therefore antagonize a cpb-caused impairment of cardiac function. This study is the continuation of these experiments with a higher number of animals and the focus on scintigraphic imaging. Animals, material, methods: 39 German landrace pigs were subdivided into three groups: group A (control) median sternotomy without cpb, group B with cpb, group C with LIM in addition to cpb. After labelling with Tc-99m-HMPAO autologues granulocytes were reinjected. Subsequently to cpb, the animals underwent scintigraphic imaging. Quantification was performed with ROI evaluation and with tissue samples (section analysis) examined in a well counter. Results:A high uptake of Tc-99m-HMPAO was found in the liver. The count rates in brain, heart, lung, spleen and kidneys were far below. The amount of Tc-99m-activity in the organ related to the half life corrected administered activity [%] was for the tissue samples (group A/B/C): brain 0.01/0.02/0.03; lung 12.1/8.3/11.5; heart 0.35/0.54/0.42; kidney 1.24/0.87/1.02; spleen 4.0/4.0/4.5, liver 16.8/20.9/19.6. The count rates determined by ROI-evaluation of the scintigraphic images related to the total count rate in the image [%] were (group A/B/C): brain 1.1/0.9/1.0; lung 15.6/10.4/12.2; heart 4.0/3.5/3.4; kidney 4.0/2.9/3.2; spleen 7.6/7.7/9.5, liver 23.1/36.7/31.4. A significant difference in the tracer uptake between the groups could neither be detected by scintigraphic imaging nor evaluation of tissue samples. Conclusion: Scintigraphic imaging as well as section analysis showed a comparable biodistribution of the tracer. Therefore, the initial results of our group were not confirmed with a considerably higher number of animals. Neither cpb nor the use of the LIM influenced distribution of Tc-99m-labelled granulocytes in pigs significantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The in vitro cytogenetic effects of the 43-kDa molecular mass exocellular glycoproteic component (GP 43) from Paracoccidioides brasiliensis were studied in cultures from human lymphocytes. The sample included 10 healthy, white, non-smoking, non-related males (mean age of 31.3 ± 8.2 years). Besides the control, three concentrations of GP 43 (0.125, 1.25 and 5 μg/ml) were used. In each group, around 1000 cells were examined in search of chromosome aberrations, and 30,000 metaphases were analysed for the determination of the Mitotic Index. The authors conclude that GP 43 most probably causes inhibition of the cell cycle and aneugenic and clastogenic effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to propose a flow spectrophotometric procedure for manganese determination in steel based on electrochemical oxidation of Mn(II) to Mn(VII) at a Pt electrode surface by means of the catalytic effect of Ag(I). The on-line oxidation step was obtained by injecting sample and electrolyte solution directly into an electrolytic cell. After electrolysis, the injectate was homogenized by bubbling air. The permanganate ions produced were passed through the spectrophotometer where absorbance was monitored at 545 nm. Effects of direct current, silver concentration, timing, flow rates, concentration and composition of support electrolyte were investigated. Direct current and silver content manifested themselves as the most relevant parameters. For determination of manganese in the 5.00 - 150 mg L -1 range (r=0,9998) and 60 s electrolysis time, the sample throughput was 20 h -1. Accuracy was assessed by analyzing ten steel standard reference materials. Results are precise (R.S.D. <3%) and in agreement with certified values of reference materials and with standard methods at 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diarylpropenamine derivatives are a class of compounds which have been evaluated as potential drug candidates. Here a specific and reproducible HPLC method for the determination of cis- and trans-isomers of the unsubstituted derivative, 3-(4'-bromo-[1,1'-biphenyl]-4-yl)-3-(4-X-phenyl-N,N-dimethyl-2-propen-1-amine (I, where X=H) in feces is described. The analyte I and internal standard, nitro derivative (II, where X=NO2), were isolated from the basified biological matrix using a liquid-liquid extraction with ethyl acetate followed by a solid-phase procedure performed on a silica cartridge. The organic phase was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The analytes were eluted with ethyl acetate-hexane-triethylamine (59:40:1) in HPLC column (silica) and detected by UV spectrophotometry at 272 nm. Linearity, precision and accuracy data for feces standards after extraction were acceptable. The method has been applied to analyses of feces samples from rats dosed with I, in which it could be anticipated that fecal excretion is quantitatively the major route for I elimination. Copyright (C) 1999 Elsevier Science B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to emphasize the technique of micro-marsupialization as an alternative for the treatment of mucus retention phenomena. Out of 41 patients, 14 were selected for treatment by the micro-marsupialization technique on the basis of clinical criteria. Patient age ranged from 5-9 years. The technique was performed as follows: the area was disinfected with 0.1% iodine; a topical anesthetic was applied to cover the entire lesion for approximately 3 min; a 4.0 silk suture was passed through the internal part of the lesion along its widest diameter; and a surgical knot was made. Of the original 14 patients treated by the micro-marsupialization technique, 12 presented full regression one week after treatment. Recurrence occurred in two cases. It was possible to conclude that the micro-marsupialization technique is an alternative to be considered, especially in pediatric dentistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Grinding process is usually the last finishing process of a precision component in the manufacturing industries. This process is utilized for manufacturing parts of different materials, so it demands results such as low roughness, dimensional and shape error control, optimum tool-life, with minimum cost and time. Damages on the parts are very expensive since the previous processes and the grinding itself are useless when the part is damaged in this stage. This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding process. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045 e VC131 steels. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate acquisition system at 2.5 MHz was used to collect the raw acoustic emission instead of root mean square value usually employed. In each test AE data was analyzed off-line, with results compared to inspection of each workpiece for burn and other metallurgical anomaly. A number of statistical signal processing tools have been evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface-relief gratings are photoinscribed on ionically adsorbed layer-by-layer (LBL) films of an azodye, Brilliant Yellow (BY), which was layered alternately with a polyelectrolyte. Photoinscription is performed by impinging an interference pattern of p- or s-polarized laser light with moderate intensity onto the LBL film, which is unlikely to cause thermal effects. Large-scale mass transport occurs due to the force associated with the field gradient of the light pattern. The ionic interactions between adjacent layers appear to provide the means for the chromophores to drag the polymer chains upon photoizomerization. LBL films were produced from two different polyelectrolytes and under two distinct pH values leading to markedly different film properties especially concerning photodegradation. Exposure to the laser light, for instance, leads to higher photodegradation in the poly(dimethyl diallylammonium chloride)/BY system, in comparison to the poly(allylamine hydrochloride)/BY films. Mass transport in the latter case is predominantly light-driven, which is consistent with the higher amplitude of modulation for p-polarized light (70 nm) compared to that caused by s-polarized light (18 nm). © 2003 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid and sensitive method is described for the determination of clofentezine residues in apple, papaya, mango and orange. The procedure is based on the extraction of the sample with a hexane:ethyl acetate mixture (1:1, v/v) and liquid chromatographic analysis using UV detection. Mean recoveries from 4 replicates of fortified fruit samples ranged from 81% to 96%, with coefficients of variation from 8.9% to 12.5%. The detection and quantification limits of the method were of 0.05 and 0.1 mg kg-1, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work it was developed a procedure for the determination of vanadium in urine samples by electrothermal atomic absorption spectrometry using successive injections for preconcentration into a preheated graphite tube. Three 60 μL volumes were sequentially injected into the atomizer preheated to a temperature of 110°C. Drying and pyrolysis steps were carried out after each injection. A chemical modifier, barium difluoride (100 mg L-1), and a surfactant, Triton X-100 (0.3% v v-1), were added to the urine sample. When injecting into a hot graphite tube, the sample flow-rate was 0.5 μL s-1. The limits of detection and quantification were 0.54 and 1.82 without preconcentration, and 0.11 and 0.37 μg L-1 with preconcentration, respectively. The accuracy of the procedure was evaluated by an addition-recovery experiment employing urine samples. Recoveries varied from 96.0 to 103% for additions ranging from 0.8 to 3.5 μg L-1 V. The developed procedure allows the determination of vanadium in urine without any sample pretreatment and with minimal dilution of the sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.