872 resultados para Validation of test results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method using liquid chromatography has been developed and validated for determination of buclizine in pharmaceutical formulations and in release studies. Isocratic chromatography was performed on a C18 column with methanol:water (80:20 v/v, pH 2.6) as mobile phase, at a flow rate of 1.0 mL/min, and UV detection at 230 nm. The method was linear, accurate, precise, sensible and robust. The dissolution test was optimized and validated in terms of dissolution medium, apparatus agitation and rotation speed. The presented analytical and dissolution procedures can be conveniently adopted in the quality and stability control of buclizine in tablets and oral suspension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to develop and validate simple, accurate and precise spectroscopic methods (multicomponent, dual wavelength and simultaneous equations) for the simultaneous estimation and dissolution testing of ofloxacin and ornidazole tablet dosage forms. The medium of dissolution used was 900 ml of 0.01N HCl, using a paddle apparatus at a stirring rate of 50 rpm. The drug release was evaluated by developed and validated spectroscopic methods. Ofloxacin and ornidazole showed 293.4 and 319.6nm as λmax in 0.01N HCl. The methods were validated to meet requirements for a global regulatory filing. The validation included linearity, precision and accuracy. In addition, recovery studies and dissolution studies of three different tablets were compared and the results obtained show no significant difference among products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scarcity of long-term series of sediment-related variables has led watershed managers to apply mathematical models to simulate sediment fluxes. Due to the high efforts for installation and maintenance of sedimentological gauges, tracers have been pointed out as an alternative to validate soil redistribution modelling. In this study, the 137Cs technique was used to assess the WASA-SED model performance at the Benguê watershed (933 km²), in the Brazilian semiarid. Qualitatively, good agreement was found among the 137Cs technique and the WASA-SED model results. Nonetheless, quantitatively great differences, up to two orders of magnitude, were found between the two methods. Among the uncertainties inherent to the 137Cs technique, definition of the reference inventory seems to be a major source of imprecision. In addition, estimations of water and sediment fluxes with mathematical models usually also present high uncertainty, contributing to the quantitative differences of the soil redistribution estimates with the two methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis presents an approach for formulating and validating a space averaged drag model for coarse mesh simulations of gas-solid flows in fluidized beds using the two-fluid model. Proper modeling for fluid dynamics is central in understanding any industrial multiphase flow. The gas-solid flows in fluidized beds are heterogeneous and usually simulated with the Eulerian description of phases. Such a description requires the usage of fine meshes and small time steps for the proper prediction of its hydrodynamics. Such constraint on the mesh and time step size results in a large number of control volumes and long computational times which are unaffordable for simulations of large scale fluidized beds. If proper closure models are not included, coarse mesh simulations for fluidized beds do not give reasonable results. The coarse mesh simulation fails to resolve the mesoscale structures and results in uniform solids concentration profiles. For a circulating fluidized bed riser, such predicted profiles result in a higher drag force between the gas and solid phase and also overestimated solids mass flux at the outlet. Thus, there is a need to formulate the closure correlations which can accurately predict the hydrodynamics using coarse meshes. This thesis uses the space averaging modeling approach in the formulation of closure models for coarse mesh simulations of the gas-solid flow in fluidized beds using Geldart group B particles. In the analysis of formulating the closure correlation for space averaged drag model, the main parameters for the modeling were found to be the averaging size, solid volume fraction, and distance from the wall. The closure model for the gas-solid drag force was formulated and validated for coarse mesh simulations of the riser, which showed the verification of this modeling approach. Coarse mesh simulations using the corrected drag model resulted in lowered values of solids mass flux. Such an approach is a promising tool in the formulation of appropriate closure models which can be used in coarse mesh simulations of large scale fluidized beds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis, a model called CFB3D is validated for oxygen combustion in circulating fluidized bed boiler. The first part of the work consists of literature review in which circulating fluidized bed and oxygen combustion technologies are studied. In addition, the modeling of circulating fluidized bed furnaces is discussed and currently available industrial scale three-dimensional furnace models are presented. The main features of CFB3D model are presented along with the theories and equations related to the model parameters used in this work. The second part of this work consists of the actual research and modeling work including measurements, model setup, and modeling results. The objectives of this thesis is to study how well CFB3D model works with oxygen combustion compared to air combustion in circulating fluidized bed boiler and what model parameters need to be adjusted when changing from air to oxygen combustion. The study is performed by modeling two air combustion cases and two oxygen combustion cases with comparable boiler loads. The cases are measured at Ciuden 30 MWth Flexi-Burn demonstration plant in April 2012. The modeled furnace temperatures match with the measurements as well in oxygen combustion cases as in air combustion cases but the modeled gas concentrations differ from the measurements clearly more in oxygen combustion cases. However, the same model parameters are optimal for both air and oxygen combustion cases. When the boiler load is changed, some combustion and heat transfer related model parameters need to be adjusted. To improve the accuracy of modeling results, better flow dynamics model should be developed in the CFB3D model. Additionally, more measurements are needed from the lower furnace to find the best model parameters for each case. The validation work needs to be continued in order to improve the modeling results and model predictability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The demand for more efficient manufacturing processes has been increasing in the last few years. The cold forging process is presented as a possible solution, because it allows the production of parts with a good surface finish and with good mechanical properties. Nevertheless, the cold forming sequence design is very empirical and it is based on the designer experience. The computational modeling of each forming process stage by the finite element method can make the sequence design faster and more efficient, decreasing the use of conventional "trial and error" methods. In this study, the application of a commercial general finite element software - ANSYS - has been applied to model a forming operation. Models have been developed to simulate the ring compression test and to simulate a basic forming operation (upsetting) that is applied in most of the cold forging parts sequences. The simulated upsetting operation is one stage of the automotive starter parts manufacturing process. Experiments have been done to obtain the stress-strain material curve, the material flow during the simulated stage, and the required forming force. These experiments provided results used as numerical model input data and as validation of model results. The comparison between experiments and numerical results confirms the developed methodology potential on die filling prediction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the problems that slows the development of off-line programming is the low static and dynamic positioning accuracy of robots. Robot calibration improves the positioning accuracy and can also be used as a diagnostic tool in robot production and maintenance. A large number of robot measurement systems are now available commercially. Yet, there is a dearth of systems that are portable, accurate and low cost. In this work a measurement system that can fill this gap in local calibration is presented. The measurement system consists of a single CCD camera mounted on the robot tool flange with a wide angle lens, and uses space resection models to measure the end-effector pose relative to a world coordinate system, considering radial distortions. Scale factors and image center are obtained with innovative techniques, making use of a multiview approach. The target plate consists of a grid of white dots impressed on a black photographic paper, and mounted on the sides of a 90-degree angle plate. Results show that the achieved average accuracy varies from 0.2mm to 0.4mm, at distances from the target from 600mm to 1000mm respectively, with different camera orientations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis method designed originally for the analysis of monosaccharides was validated using reference solutions of polydatin. The validation was conducted by studying and determining the concentration levels of LOD and LOQ and the range of linearity and by determining levels of uncertainty in respect to repeatability and reproducibility. The reliability of the gained results is also discussed. A guide with recommendations considering the validation and overall design of analysis sequences with CE is also produced as a result of this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A web service is a software system that provides a machine-processable interface to the other machines over the network using different Internet protocols. They are being increasingly used in the industry in order to automate different tasks and offer services to a wider audience. The REST architectural style aims at producing scalable and extensible web services using technologies that play well with the existing tools and infrastructure of the web. It provides a uniform set of operation that can be used to invoke a CRUD interface (create, retrieve, update and delete) of a web service. The stateless behavior of the service interface requires that every request to a resource is independent of the previous ones facilitating scalability. Automated systems, e.g., hotel reservation systems, provide advanced scenarios for stateful services that require a certain sequence of requests that must be followed in order to fulfill the service goals. Designing and developing such services for advanced scenarios with REST constraints require rigorous approaches that are capable of creating web services that can be trusted for their behavior. Systems that can be trusted for their behavior can be termed as dependable systems. This thesis presents an integrated design, analysis and validation approach that facilitates the service developer to create dependable and stateful REST web services. The main contribution of this thesis is that we provide a novel model-driven methodology to design behavioral REST web service interfaces and their compositions. The behavioral interfaces provide information on what methods can be invoked on a service and the pre- and post-conditions of these methods. The methodology uses Unified Modeling Language (UML), as the modeling language, which has a wide user base and has mature tools that are continuously evolving. We have used UML class diagram and UML state machine diagram with additional design constraints to provide resource and behavioral models, respectively, for designing REST web service interfaces. These service design models serve as a specification document and the information presented in them have manifold applications. The service design models also contain information about the time and domain requirements of the service that can help in requirement traceability which is an important part of our approach. Requirement traceability helps in capturing faults in the design models and other elements of software development environment by tracing back and forth the unfulfilled requirements of the service. The information about service actors is also included in the design models which is required for authenticating the service requests by authorized actors since not all types of users have access to all the resources. In addition, following our design approach, the service developer can ensure that the designed web service interfaces will be REST compliant. The second contribution of this thesis is consistency analysis of the behavioral REST interfaces. To overcome the inconsistency problem and design errors in our service models, we have used semantic technologies. The REST interfaces are represented in web ontology language, OWL2, that can be part of the semantic web. These interfaces are used with OWL 2 reasoners to check unsatisfiable concepts which result in implementations that fail. This work is fully automated thanks to the implemented translation tool and the existing OWL 2 reasoners. The third contribution of this thesis is the verification and validation of REST web services. We have used model checking techniques with UPPAAL model checker for this purpose. The timed automata of UML based service design models are generated with our transformation tool that are verified for their basic characteristics like deadlock freedom, liveness, reachability and safety. The implementation of a web service is tested using a black-box testing approach. Test cases are generated from the UPPAAL timed automata and using the online testing tool, UPPAAL TRON, the service implementation is validated at runtime against its specifications. Requirement traceability is also addressed in our validation approach with which we can see what service goals are met and trace back the unfulfilled service goals to detect the faults in the design models. A final contribution of the thesis is an implementation of behavioral REST interfaces and service monitors from the service design models. The partial code generation tool creates code skeletons of REST web services with method pre and post-conditions. The preconditions of methods constrain the user to invoke the stateful REST service under the right conditions and the post condition constraint the service developer to implement the right functionality. The details of the methods can be manually inserted by the developer as required. We do not target complete automation because we focus only on the interface aspects of the web service. The applicability of the approach is demonstrated with a pedagogical example of a hotel room booking service and a relatively complex worked example of holiday booking service taken from the industrial context. The former example presents a simple explanation of the approach and the later worked example shows how stateful and timed web services offering complex scenarios and involving other web services can be constructed using our approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to translate the Roland-Morris (RM) questionnaire into Brazilian-Portuguese and adapt and validate it. First 3 English teachers independently translated the original questionnaire into Brazilian-Portuguese and a consensus version was generated. Later, 3 other translators, blind to the original questionnaire, performed a back translation. This version was then compared with the original English questionnaire. Discrepancies were discussed and solved by a panel of 3 rheumatologists and the final Brazilian version was established (Brazil-RM). This version was then pretested on 30 chronic low back pain patients consecutively selected from the spine disorders outpatient clinic. In addition to the traditional clinical outcome measures, the Brazil-RM, a 6-point pain scale (from no pain to unbearable pain), and its numerical pain rating scale (PS) (0 to 5) and a visual analog scale (VAS) (0 to 10) were administered twice by one interviewer (1 week apart) and once by one independent interviewer. Spearman's correlation coefficient (SCC) and intraclass correlation coefficient (ICC) were computed to assess test-retest and interobserver reliability. Cross-sectional construct validity was evaluated using the SCC. In the pretesting session, all questions were well understood by the patients. The mean time of questionnaire administration was 4 min and 53 s. The SCC and ICC were 0.88 (P<0.01) and 0.94, respectively, for the test-retest reliability and 0.86 (P<0.01) and 0.95, respectively, for interobserver reliability. The correlation coefficient was 0.80 (P<0.01) between the PS and Brazil-RM score and 0.79 (P<0.01) between the VAS and Brazil-RM score. We conclude that the Brazil-RM was successfully translated and adapted for application to Brazilian patients, with satisfactory reliability and cross-sectional construct validity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to translate the Kidney Disease Quality of Life - Short Form (KDQOL-SF™1.3) questionnaire into Portuguese to adapt it culturally and validate it for the Brazilian population. The KDQOL-SF was translated into Portuguese and back-translated twice into English. Patient difficulties in understanding the questionnaire were evaluated by a panel of experts and solved. Measurement properties such as reliability and validity were determined by applying the questionnaire to 94 end-stage renal disease patients on chronic dialysis. The Nottingham Health Profile Questionnaire, the Karnofsky Performance Scale and the Kidney Disease Questionnaire were administered to test validity. Some activities included in the original instrument were considered to be incompatible with the activities usually performed by the Brazilian population and were replaced. The mean scores for the 19 components of the KDQOL-SF questionnaire in Portuguese ranged from 22 to 91. The components "Social support" and "Dialysis staff encouragement" had the highest scores (86.7 and 90.8, respectively). The test-retest reliability and the inter-observer reliability of the instrument were evaluated by the intraclass correlation coefficient. The coefficients for both reliability tests were statistically significant for all scales of the KDQOL-SF (P < 0.001), ranging from 0.492 to 0.936 for test-retest reliability and from 0.337 to 0.994 for inter-observer reliability. The Cronbach's alpha coefficient was higher than 0.80 for most of components. The Portuguese version of the KDQOL-SF questionnaire proved to be valid and reliable for the evaluation of quality of life of Brazilian patients with end-stage renal disease on chronic dialysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to investigate the psychometric properties and cross-cultural validity of the Beck Depression Inventory (BDI) among ethnic Chinese living in the city of São Paulo, Brazil. The study was conducted on 208 community individuals. Reliability and discriminant analysis were used to test the psychometric properties and validity of the BDI. Principal component analysis was performed to assess the BDI's factor structure for the total sample and by gender. The mean BDI score was lower (6.74, SD = 5.98) than observed in Western counterparts and showed no gender difference, good internal consistency (Cronbach's alpha 0.82), and high discrimination of depressive symptoms (75-100%). Factor analysis extracted two factors for the total sample and each gender: cognitive-affective dimension and somatic dimension. We conclude that depressive symptoms can be reliably assessed by the BDI in the Brazilian Chinese population, with a validity comparable to that for international studies. Indeed, cultural and measurement biases might have influenced the response of Chinese subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Graphite furnace atomic absorption spectrometry (GF AAS) was the technique chosen by the inorganic contamination laboratory (INCQ/ FIOCRUZ) to be validated and applied in routine analysis for arsenic detection and quantification. The selectivity, linearity, sensibility, detection, and quantification limits besides accuracy and precision parameters were studied and optimized under Stabilized Temperature Platform Furnace (STPF) conditions. The limit of detection obtained was 0.13 µg.L-1 and the limit of quantification was 1.04 µg.L-1, with an average precision, for total arsenic, less than 15% and an accuracy of 96%. To quantify the chemical species As(III) and As(V), an ion-exchange resin (Dowex 1X8, Cl- form) was used and the physical-chemical parameters were optimized resulting in a recuperation of 98% of As(III) and of 90% of As(V). The method was applied to groundwater, mineral water, and hemodialysis purified water samples. All results obtained were lower than the maximum limit values established by the legal Brazilian regulations, in effect, 50, 10, and 5 µg.L-1 para As total, As(III) e As(V), respectively. All results were statistically evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate cancer (PCa) has emerged as the most commonly diagnosed lethal cancer in European men. PCa is a heterogeneous cancer that in the majority of the cases is slow growing: consequently, these patients would not need any medical treatment. Currently, the measurement of prostate-specific antigen (PSA) from blood by immunoassay followed by digital rectal examination and a pathological examination of prostate tissue biopsies are the most widely used methods in the diagnosis of PCa. These methods suffer from a lack of sensitivity and specificity that may cause either missed cancers or overtreatment as a consequence of over-diagnosis. Therefore, more reliable biomarkers are needed for a better discrimination between indolent and potentially aggressive cancers. The aim of this thesis was the identification and validation of novel biomarkers for PCa. The mRNA expression level of 14 genes including AMACR, AR, PCA3, SPINK1, TMPRSS2-ERG, KLK3, ACSM1, CACNA1D, DLX1, LMNB1, PLA2G7, RHOU, SPON2, and TDRD1 was measured by a truly quantitative reverse transcription PCR in different prostate tissue samples from men with and without PCa. For the last eight genes the function of the genes in PCa progression was studied by a specific siRNA knockdown in PC-3 and VCaP cells. The results from radical prostatectomy and cystoprostatectomy samples showed statistically significant overexpression for all the target genes, except for KLK3 in men with PCa compared with men without PCa. Statistically significant difference was also observed in low versus high Gleason grade tumors (for PLA2G7), PSA relapse versus no relapse (for SPON2), and low versus high TNM stages (for CACNA1D and DLX1). Functional studies and siRNA silencing results revealed a cytotoxicity effect for the knock-down of DLX1, PLA2G7, and RHOU, and altered tumor cell invasion for PLA2G7, RHOU, ACSM1, and CACNA1D knock-down in 3D conditions. In addition, effects on tumor cell motility were observed after silencing PLA2G7 and RHOU in 2D monolayer cultures. Altogether, these findings indicate the possibility of utilizing these new markers as diagnostic and prognostic markers, and they may also represent therapeutic targets for PCa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le but de cette étude était d’évaluer les qualifications de performance du système FlexiWare® chez le rat male Sprague Dawley et le singe Cynomolgus éveillés, ainsi que chez le chien Beagle éveillé et anesthésié, suite à l’administration de produits ayant une activité pharmacologique connue. Les produits utilisés incluaient l’albutérol administré par inhalation, la méthacholine, et le rémifentanil administrés par voie intraveineuse. Une solution saline administré par voie intraveneuse, a été utilisée comme substance témoin. Différentes variables ont servi à évaluer la réponse des animaux (rats, chien, singe). Ces dernières comprenaient la fréquence respiratoire (RR), le volume courant (TV), la ventilation minute (MV). Des paramètres additionnels ont été évalués chez le rat, soit les temps d’inspiration (IT) et d’expiration (ET), le temps du pic de débit expiratoire, les pics de débits inspiratoire et expiratoire, le ratio inspiratoire:expiratoire (I:E), le ratio inspiratoire sur respiration totale (I:TB), et l’écoulement expiratoire moyen (EF50). Les résultats obtenus ont démontré que le système FlexiWare® était suffisamment sensible et spécifique pour dépister, chez les espèces animales utilisées, les effets bronchodilateur, bronchoconstricteur et dépresseur central des substances testées. Il pourrait faire partie des méthodes (ICH 2000) utilisées en pharmacologie de sécurité lors de l’évaluation de substances pharmacologiques sur le système respiratoire des animaux de laboratoire. Les espèces animales utilisées ont semblé s’adapter aisément aux procédures de contention. Les paramètres évalués, RR, TV et MV ont permis de caractériser la réponse des animaux suite à l’administration de produits pharmacologiques à effets connus, judicieusement complétés par les variables de débit. L’ajout de paramètres du temps n’était pas primordiale pour détecter les effets des drogues, mais offre des outils complémentaires d’interpréter les changements physiologiques. Cependant, chez le rat conscient, la période d’évaluation ne devrait pas s’étendre au-delà d’une période de deux heures post traitement. Ces études constituent une évaluation des qualifications de performance de cet appareil et ont démontré de manière originale, la validation concurrentielle, en terme de précision (sensibilité et spécificité) et fiabilité pour différentes variables et sur différentes espèces.