893 resultados para Musculoskeletal ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of power ultrasound treatment in dry red kidney beans as a means to reduce the rehydration step during canning production while maintaining high nutritional value. IFT Annual Meeting. Chicago, 13-16/7/2013. (Poster

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound has long been recognized as a means of effecting change at the cellular and tissue levels [1-3], which may be enhanced in the presence of photosensitive agents [4-6]. During insonation, the presence of bubbles can also play a role, creating strong microstreaming effects in solution and in more dramatic circumstances leading to the formation of energetic microjets [7], plasmas [8], and the production of other highly reactive species [9]. Such sonodynamic activity has generated particular excitement in the medical community as it Moreover the dual role for microbubbles as both an adjunct to therapy and a diagnostic echogenicity enhancer has seen industry take a proactive role in their development. In the present paper we studied the role of ultrasound driven sonoluminescent light on the degradation of a fluorescent test species (rhodamine) in the presence of an archetypal photocatalyst material, TiO 2, with a view to exploring its exploitation potential for downstream medical applications. We found that, whilst the efficiency of this process is seen to be low compared with conventional ultra-violet sources, we advocate the further exploration of the sonoluminescent approach given its potential for non-invasive applications. A strategy for enhancing the effect is also suggested. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Musculoskeletal (MSK) complaints are common within primary care (1) (2) (3) but some General Practitioners (GPs)/family physicians do not feel comfortable managing these symptoms (3), preferring to refer onto hospital specialists or Integrated Clinical Assessment and Treatment Services (ICATs). Long waiting times for hospital outpatient reviews are a major cause of patient inconvenience and complaints (4). We therefore aimed to establish a GP-ran MSK and sport and exercise medicine (SEM) clinic based within a Belfast GP surgery that would contribute to a sustainable improvement in managing these common conditions within primary care as well as reducing waiting times for patients with these conditions to see a specialist. This shift from hospital-based to community-based management is in-keeping with recent policy changes within the UK health-system, including Transforming Your Care within Northern Ireland (NI) (5). The GP-ran MSK and SEM clinic was held monthly within a Belfast GP practice, staffed by one GP with a specialist interest in MSK and SEM conditions and its performance was reviewed over a three month period. Parameters audited included cases seen, orthopaedic and x-ray referral rates and secondary care referrals comparing the GP practice’s performance to the same time period in the previous year as well as patient satisfaction questionnaires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The identification of pre-clinical microvascular damage in hypertension by non-invasive techniques has proved frustrating for clinicians. This proof of concept study investigated whether entropy, a novel summary measure for characterizing blood velocity waveforms, is altered in participants with hypertension and may therefore be useful in risk stratification.

Methods: Doppler ultrasound waveforms were obtained from the carotid and retrobulbar circulation in 42 participants with uncomplicated grade 1 hypertension (mean systolic/diastolic blood pressure (BP) 142/92 mmHg), and 26 healthy controls (mean systolic/diastolic BP 116/69 mmHg). Mean wavelet entropy was derived from flow-velocity data and compared with traditional haemodynamic measures of microvascular function, namely the resistive and pulsatility indices.

Results: Entropy, was significantly higher in control participants in the central retinal artery (CRA) (differential mean 0.11 (standard error 0.05 cms(-1)), CI 0.009 to 0.219, p 0.017) and ophthalmic artery (0.12 (0.05), CI 0.004 to 0.215, p 0.04). In comparison, the resistive index (0.12 (0.05), CI 0.005 to 0.226, p 0.029) and pulsatility index (0.96 (0.38), CI 0.19 to 1.72, p 0.015) showed significant differences between groups in the CRA alone. Regression analysis indicated that entropy was significantly influenced by age and systolic blood pressure (r values 0.4-0.6). None of the measures were significantly altered in the larger conduit vessel.

Conclusion: This is the first application of entropy to human blood velocity waveform analysis and shows that this new technique has the ability to discriminate health from early hypertensive disease, thereby promoting the early identification of cardiovascular disease in a young hypertensive population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem-Musculoskeletal (MSK) symptoms are common within primary care but some GPs are not comfortable managing these; waiting times for hospital appointments are a major cause of patients’ complaints. Current UK healthcare policies emphasise a need for more community-based management. We aimed to pilot an innovative general practice-based clinic to improve the management of MSK and Sport and Exercise Medicine (SEM) symptoms within general practice.

The approach-This project was conducted in an inner-city practice of approximately 9,000 patients and 5 GP partners. The practice commissioned a novel monthly 4-hour clinic staffed by one GP with a specialist interest in MSK and SEM conditions. Each patient was allocated a 20-minute appointment. All primary care staff within the practice could refer any patient for whom they considered hospital referral appropriate, with no specific exclusion criteria. Management plans included injection therapy, exercise prescription and onward referral. After three months (August-October 2014) numbers of consultations, sources of referral, reasons for referral and management outcomes were described; patient satisfaction was assessed by questionnaire, offered to 10 randomly selected patients by reception staff and self-completed by patients. Costs of the clinic were compared to current options.

Findings- All patients (14 males; 21 females; aged 35-77 years), were seen within four weeks of referral (one third of orthopaedic referrals in 2013 waited over 9 weeks for appointment). Most were referred from other GPs; some came from physiotherapy and podiatry. Shoulder problems were the most frequent reason for referral. The commonest management option was steroid injection, with most patients being given advice regarding exercise and analgesia; there were 3 onward referrals (2 physiotherapy; 1 rheumatology).

Comparing August-October data in 2014 and 2013, total, orthopaedic and rheumatology referrals were reduced by 147, 2 and 3, respectively; within the practice MSK presentations and physiotherapy and x-ray referrals were 60, 47 and 90 fewer, respectively.

The cost per attendance at the clinic was £61; initial orthopaedic-ICAT assessments cost £82 and a consultant appointment £213.

Satisfaction questionnaires were returned by all 10 selected participants and provided positive feedback, expressing preference for community-based, rather than hospital, management.

Consequence- Our pilot study indicates that this novel service model has potential for efficient and effective management of MSK and SEM complaints in primary care, reducing the need for hospital referral and the clinical burden on general practices. The innovation deserves further evaluation in a full-scale trial to determine its generalisability to other practice settings and populations.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wavelet entropy assesses the degree of order or disorder in signals and presents this complex information in a simple metric. Relative wavelet entropy assesses the similarity between the spectral distributions of two signals, again in a simple metric. Wavelet entropy is therefore potentially a very attractive tool for waveform analysis. The ability of this method to track the effects of pharmacologic modulation of vascular function on Doppler blood velocity waveforms was assessed. Waveforms were captured from ophthalmic arteries of 10 healthy subjects at baseline, after the administration of glyceryl trinitrate (GTN) and after two doses of N(G)-nitro-L-arginine-methyl ester (L-NAME) to produce vasodilation and vasoconstriction, respectively. Wavelet entropy had a tendency to decrease from baseline in response to GTN, but significantly increased after the administration of L-NAME (mean: 1.60 ± 0.07 after 0.25 mg/kg and 1.72 ± 0.13 after 0.5 mg/kg vs. 1.50 ± 0.10 at baseline, p < 0.05). Relative wavelet entropy had a spectral distribution from increasing doses of L-NAME comparable to baseline, 0.07 ± 0.04 and 0.08 ± 0.03, respectively, whereas GTN had the most dissimilar spectral distribution compared with baseline (0.17 ± 0.08, p = 0.002). Wavelet entropy can detect subtle changes in Doppler blood velocity waveform structure in response to nitric-oxide-mediated changes in arteriolar smooth muscle tone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Roughly one in four breast cancer survivors report some degree of arm oedema. Lymphoedema is a build-up of excess lymph fluids in the tissues. Persistent lymphoedema leads to pain, diminished limb function, increased risk of infection, soft tissue fibrosis, and severe cases can be grossly disfiguring. From a mechanics perspective, the lymphoedemous tissue may be thought of as a two phase composite, consisting of both fluid and solid phases. Here we discuss the use of composites mixture theory to model the mechanics of lymphoedemous tissues. By treating the tissue as a fluid-solid composite, rules-of-mixtures may be used to estimate the effective moduli in terms of the properties of the individual components and their respective volume fractions in these two states.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the assessment of time-shifts (TS) from backscattered ultrasound (BSU) signals when large temperature variations (up to 15 degrees C) were induced in a gel-based phantom. The results showed that during cooling temperature is linear with TS at a rate of approximately 74 ns/degrees C. However during a complete heating/cooling cycle, the relation is highly non-linear. This can be explained by the fact that during cooling the temperature distribution is more uniform. Another problem to report is that TS is very sensitive to external movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of blood-flow Doppler ultrasound spectral content is currently performed on clinical diagnosis. Since mean frequency and bandwidth spectral parameters are determinants on the quantification of stenotic degree, more precise estimators than the conventional Fourier transform should be seek. This paper summarizes studies led by the author in this field, as well as the strategies used to implement the methods in real-time. Regarding stationary and nonstationary characteristics of the blood-flow signal, different models were assessed. When autoregressive and autoregressive moving average models were compared with the traditional Fourier based methods in terms of their statistical performance while estimating both spectral parameters, the Modified Covariance model was identified by the cost/benefit criterion as the estimator presenting better performance. The performance of three time-frequency distributions and the Short Time Fourier Transform was also compared. The Choi-Williams distribution proved to be more accurate than the other methods. The identified spectral estimators were developed and optimized using high performance techniques. Homogeneous and heterogeneous architectures supporting multiple instruction multiple data parallel processing were essayed. Results obtained proved that real-time implementation of the blood-flow estimators is feasible, enhancing the usage of more complex spectral models on other ultrasonic systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Engenharia Electrónica e Telecomunicações, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Medicina Dentária (Dentisteria Conservadora), Universidade de Lisboa, Faculdade de Medicina Dentária, 2016