984 resultados para Electronic portal imaging device


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider a cavity with a vibrating end mirror and coupled to a Bose-Einstein condensate. The cavity field mediates the interplay between mirror and collective oscillations of the atomic density. We study the implications of this dynamics and the possibility of an indirect diagnostic. Our predictions can be observed in a realistic setup that is central to the current quest for mesoscopic quantumness.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Staphylococcus epidermidis, the most frequently isolated coagulase-negative staphylococcus, is the leading cause of infection related to implanted medical devices (IMDs). This is directly related to its capability to establish multilayered, highly structured biofilms on artificial surfaces. At present, conventional systemic therapies using standard antimicrobial agents represent the main strategy to treat and prevent medical device-associated infections. However, device-related infections are notoriously difficult to treat and bacteria within biofilm communities on the surface of IMDs frequently outlive treatment, and removal of the medical device is often required for successful therapy. Importantly, major advances in this research area have been made, leading to a greater understanding of the complexities of biofilm formation of S. epidermidis and resulting in significant developments in the treatment and prevention of infections related to this member of the coagulase-negative group of staphylococci. This review will examine the pathogenesis of the clinically significant S. epidermidis and provide an overview of the conventional and emerging antibiofilm approaches in the management of medical device-associated infections related to this important nosocomial pathogen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The potential of employing a millimetre-wave MMIC reflection amplifier as a building block for a retrodirective reflectarray is investigated. With this in mind the phase conjugating behaviour of the device is experimentally quantified at 21 GHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental results are presented for the focusing capability of an active phase conjugating lens for a single and a dipole source pair and these are compared with predictions. In addition for a single source we illustrate the ability of the lens to project a null at the lens focus instead of a peak. A scheme is also presented such that when a source or pair of sources is imaged through an identical pair of passive scatterers located symmetrically about the lens that imaging with sub-wavelength resolution is possible. The rationale for the operation of the lens and aberrations observed due to its finite array size is discussed and is supported throughout by means of numerical simulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A prototype X-band scale model for a quasi-optical three-port circulator utilising a double-layer circularly polarising frequency selective surface is proposed. The operating principles and measured characteristics of the device are discussed. A prototype device operating at 9.9 GHz has been built and validated experimentally. The port 1 to port 2 insertion loss of the quasi-circulator has been measured to be 2 dB, while port 1 to port 3 isolation is 16 dB. It is demonstrated that port 1 to 3 isolation can be increased to 25 dB by embedding the quasi-circulator in a feedforward setup.