996 resultados para Coroa dentária - adaptação
Resumo:
Due to advances in the manufacturing process of orthopedic prostheses, the need for better quality shape reading techniques (i.e. with less uncertainty) of the residual limb of amputees became a challenge. To overcome these problems means to be able in obtaining accurate geometry information of the limb and, consequently, better manufacturing processes of both transfemural and transtibial prosthetic sockets. The key point for this task is to customize these readings trying to be as faithful as possible to the real profile of each patient. Within this context, firstly two prototype versions (α and β) of a 3D mechanical scanner for reading residual limbs shape based on reverse engineering techniques were designed. Prototype β is an improved version of prototype α, despite remaining working in analogical mode. Both prototypes are capable of producing a CAD representation of the limb via appropriated graphical sheets and were conceived to work purely by mechanical means. The first results were encouraging as they were able to achieve a great decrease concerning the degree of uncertainty of measurements when compared to traditional methods that are very inaccurate and outdated. For instance, it's not unusual to see these archaic methods in action by making use of ordinary home kind measure-tapes for exploring the limb's shape. Although prototype β improved the readings, it still required someone to input the plotted points (i.e. those marked in disk shape graphical sheets) to an academic CAD software called OrtoCAD. This task is performed by manual typing which is time consuming and carries very limited reliability. Furthermore, the number of coordinates obtained from the purely mechanical system is limited to sub-divisions of the graphical sheet (it records a point every 10 degrees with a resolution of one millimeter). These drawbacks were overcome by designing the second release of prototype β in which it was developed an electronic variation of the reading table components now capable of performing an automatic reading (i.e. no human intervention in digital mode). An interface software (i.e. drive) was built to facilitate data transfer. Much better results were obtained meaning less degree of uncertainty (it records a point every 2 degrees with a resolution of 1/10 mm). Additionally, it was proposed an algorithm to convert the CAD geometry, used by OrtoCAD, to an appropriate format and enabling the use of rapid prototyping equipment aiming future automation of the manufacturing process of prosthetic sockets.
Resumo:
The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory
Tradução e adaptação transcultural do instrumento de avaliação prenatal selfevaluation questionnaire
Resumo:
Introduction: The human gestation period is 40 weeks. This is the essential time for maternal psychosocial adaptation, in which there is the intense transformation of a life without offspring into a life with one or more children. The Pregnancy Self-Evaluation Questionnaire (PSEQ) has 79 items, subdivided into seven subcategories: acceptance of pregnancy, identification with the maternal role, well-being of mother and baby, preparing for labor, control in labor, relationship with the mother and the relationship with the partner. Objective: To translate and cross-culturally adapt the instrument PSEQ to be used with Brazilian women. Methods: It is a cross-sectional observational study. We followed some methodological steps to achieve the cross-cultural adaptation of this measuring instrument. They are: translation, synthesis, back translation, analysis of the committee of specialists and pre-test. Another questionnaire was applied to characterize the socio-demographic and clinical status of the pregnant women (n = 36). The descriptive statistics was gotten through the average, standard deviation (SD), absolute and relative frequency. The statistical test used for the analysis of the internal consistency was Cronbach's alpha coefficient, using SPSS version 17.0. Results: The volunteers had low socioeconomic status, average age of 25.1 years (± 5.52), and average gestational age of 25.9 weeks (± 8.11). 58.3% of these volunteers had not planned their current pregnancy. The pretest showed that 75% of pregnant women found the questionnaire easy to understand. There was an average of 76.9 (± 3.23) answered items among the participants. Regarding the instrument PSEQ, the identification with the maternal role was the subcategory which showed the highest average 24.8 (± 5.6), while the relationship with the mother had the lowest average 15.4 (± 7.7). The internal consistency ranged from 0.52-0.89. Conclusion: The translation and cross-cultural adaptation of the PSEQ to Portuguese language were carried out with methodological rigor and can be considered an instrument with good internal consistency
Resumo:
Introdução: The scales of cognitive screening are important tools for early detection of dementia, creating the possibility of developing measures to slow this process and assist in the management of the disease. Objective: To validate the Leganés Cognitive Test (Prueba Cognitive de Leganés) (PCL) for cognitive screening in low educated elderly Brazilians. Methods: The study sample was composed of 59 elderly residents from the city of Santa Cruz, Brazil with low schooling levels. Reliability was analyzed with a 2-day interval between assessments, and concurrent validity was assessed using the Mini Mental State Examination (MMSE). Results: According to the PCL, the prevalence of dementia was 11.8%. The scale items showed a moderate to strong correlation between domains (p <0.01), and inter-rater reliability exhibited ICC = 0.81, 95% CI (0.72-0.88). Factor analysis resulted in two factors: memory and orientation. Interscale agreement was considered poor (k = - 0.02), supporting the hypothesis of an educational impact on final MMSE scores. Conclusion: The results suggest that PCL has acceptable levels of reliability for use in low educated elderly Brazilians
Resumo:
Objectives: to translate and assess the psychometric properties of the Brazilian short-form of the Mobility Assessment Tool (MAT-sf) in Brazilians community elderly. Methds: the 12 items MAT-sf went through the process of translation and back translation into Portuguese of the Brazil, considering the semantic and cultural adaptation. In a sample of 150 aged 65-74 years living in the community, the instrument's psychometric properties were evaluated by analysis of convergent and construct validity and test-retest reliability. The main outcomes measures used for validation included in the battery of tests of physical ability, self-repor measures of functional limitations, health, depression, cognitive and sex. The test-retest reliability of the instrument was assessed using the intra-class correlation coefficient (ICC), 40 subjects were reassessed after an interval of 14 days of assessment. Results: the concurrent validity for the MAT-sf was evidenced by significant correlations with SPPB (r = 0,53), number of functional limitations (r = -0,62) and depressive symptoms (r = -0,45). The construct validity of the instrument was measured by gradual and significant increase of the MAT-sf scores with high levels of physical performance and with positive self-reported health, also found that MAT-sf scores were statistically differents according to sex. The variation in MAT-sf scores (R2 = 0,41) was explained by SPPB, number of limitations for activities of daily life and depressive symptoms. High values for test-retest reliability was evidencend by ICC = 0,94, 95% CI = 0,90 0,97. Conclusions: the Brazilian version of the short-form of the Mobility Assessment Tool has values of validity and reliability to ensure its use in elderly populations living in communities
Resumo:
The purpose of this study was to evaluate the effectiveness during a twelve-month period, of resin-modified glass ionomer (Vitremer@) used as fissure sealants compared to supervised teeth brushing in the prevention of oclusal caries in permarient molars of pubIlc school children from 5 to 7 years of age. A total of 91 children participated in the study, being randomly divided up into three groups of investigation: group with sealant (n=31), group of supervised brushing (m=30), and control gorup (n=30). After 12 months, a total of 28.5% of tosses in the sample of 26 children was registered, and although there wasn t a significant diference between these losses and the groups studles (p = 0.6355), there was a considerable reduction in the sample. The results showed that none of the independentIy studied variables (present caries experience, biofilm, bleeding, sealant retention, position of the tooth in the arch, and sex) interfered in the final results, and that there was no significant difference between applying the sealant in question, perfornling supervised dental brushing, or not intervening at alI (p=0.542). These results could have been a consequence of the limitations found alI through the study, especially relating to the losses occurred because of school evasion, transfer, or because of the accident in the Marise Paiva Municipal School, Keeping students away for approximately one semester, so tht a new reseach had to be developed sos as to better clarify the effects among the treatments done there
Resumo:
The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle
Resumo:
The study of the motivation to practice physical activities is relevant once through this it is possible to develop intervention strategies for sedentary population. In this way, the present dissertation aimed to adapt and validate for the Brazilian context the Motives for Physical Activity Measure Revised (MPAM-R). It was investigated yet the relation of some socio-demographic variables (age, gender, Body Mass Index - BMI, types of physical activity; way to practice and time of practice) and the participants means in the motives studied. The physical activity (PA) is defined as any bodily movement produced by skeletal muscles resulting in energy expenditure above the basal level. However, in the present study it was considered motivation for two types of PA: the physical exercises and sports. The Self-Determination Theory (SDT) underlay this research, once it has been used in the sportive context, beyond the facto of it was used as theoretical base to the development of MPAM-R. To attain the proposed goals, it was accomplished translations to Portuguese of the original English scale. Next, was carried out the semantic analysis and the judge analysis. For the empirical analysis of items, participated 309 practitioner of PA, classified in physical exercises practitioners and sports practitioners, with ages between 16 and 74 years, distributed equally by sex. They answered the final version in Portuguese of the MPAM-R and socio-demographic questions. The data was collected in Natal/RN, where the researcher approached people in some places where the PA is practiced, following she communicated that their involvement will be spontaneous and their responses will be confidential. The obtained results pointed the confirmation of the existence of five factors in the final version of the instrument, that was composed by 26 items that presented the following statistics indexes: x² (289) = 757.75, p < 0.000, x²/DF = 2.62, with GFI of 0.83, AGFI of 0.80 and RMSEA of 0.07. The reliability (Cronbach Alpha) of the complete instrument was 0.90, and the indexes of each factor were considered satisfactory too: Enjoyment (α = 0.88), Health (α = 0.84), Appearance (α = 0.79), Competence (α = 0.85) and Social (α = 0.75). It was observed that, in general, the main motive presented by the participants to practice PA was Health. It was verified yet, that women and aged had a higher mean in the Health factor; among the exercise practitioners was found a higher mean in the Appearance factor; and a higher mean in the Social factor was found among those that practice PA with accompaniment. It was concluded that the MPAM-R presented satisfactory psychometric parameters, became it useful in futures researches. Moreover, proposed the accomplishment of new studies that considered others variables to the intent of the better understanding of motivation to practice physical activity
Resumo:
While providing physical and psychological benefits, excessive exercise could be or cause a compulsive behavior, making the individual dependent on it. In a parallel discussion, computerized psychological instruments, for a hand, reflects the development of information technology and your applicability to other areas, but also shows little advance for Psychological Assessment. In this perspective, this study aims to adapt the Exercise Dependence Scale (EDS-R) in two formats (paper-and-pencil and computerized) and evaluate evidence of factorial and convergent validity, and reliability of each version and compare them with each other. It is also proposed to observe the relationship of some bio-demographic (Sex, age, frequency, duration and intensity of practice exercise) and the exercise dependence (DEF). For this purpose, 709 regular physical activity practitioners, selected by procedures non-probabilistic sampling, responded a adapted version of EDS-R, Muscle Appearance Satisfaction Scale (MASS), Body Modification Scale (BMS) and a demographic questionnaire, analyzed through Exploratory Factor Analysis, Cronbach's Alpha and not parametric tests. Both the traditional version and the computer showed a seven factors structure, explaining 57 and 62% of the variance, respectively, and Cronbach's alphas of 0.83 and 0.89. Factors were: (1) intentionality, (2) continuity, (3) tolerance, (4) reduction of other activities, (5) lack of control, (6) abstinence and (7) time spent on exercise. Relationships were observed between the Exercise Dependence and the variables: age, diets, consumption of food supplements and medicines for weight change, desire to do plastic surgery and body satisfaction. We observed also a positive correlation between the DEF and the frequency, duration and intensity of exercise, and the factor "Dependence on exercising" from MASS, indicating convergent validity of the EDS-R. Finally, comparisons between the two formats were equivalent, with few changes: computerized version achieved higher DEF scores. Based on these results, it can be concluded that the EDS-R has factorial and convergent validity, reliability, to measure exerceise dependence on traditional e computerized formats. DEF is related to actions used to body modification and behaviors toward exercise. Finally, it was found equivalence between the formats, especially in psychometric parameters, thus suggesting feasibility of a computerized assessment. However, it was observed that the computerized data has sample recruiting strategies more limited
Resumo:
Millon describes the normal personality by means of adaptation styles that are effective in normal environments and personality disorders such as unadapted operating styles. To operacionalize his theoretical model, Millon has built several instruments, including the Millon Clinical Multiaxial Inventory III (MCMI-III), wich consists of a self report inventory composed by 175 true or false response items, containing four verification scales, and others scales wich evaluates 14 personality patterns and 10 clinical syndromes. The Substance Dependence scale (T) is placed along with Clinical Syndromes scales. This research is justified by the lack of a Brazilian instrument to assess personality psychopathological aspects, and aims to translate and semantically adapt the MCMI-III to the Brazilian context, checking validity elements of the Substance Dependence scale, and developing a computer application for assisting the evaluation of assessment results. To this intent, 2.588 individuals data was collected, male and female, aged between 18 and 85 years, characterized as belonging to a clinical or non-clinical group, who took part in the survey via the internet or in person. Respondents completed the MCMI-III, a socio-demographic questionnaire and a subgroup also answered to the Goldberg General Health Questionnaire (GHQ). Besides descriptive statistics, we performed the analysis using the Student t test, principal components analysis and internal consistency. Despite difficulties related to translating very specific English terms, the assessment by judges, experts on Millon´s theory, and the back translation, attested the adequacy of the Brazilian version. Factorial analysis indicated the grouping of translated T scale items into three factors (social activities prejudice, lack of impulse control, and oppositional behavior), by presenting a single item on a fourth factor (apparently related to seeking pleasurable stimuli). The Cronbach alpha for this set of items was 0,82, indicating an acceptable scale reliability. The data analysis resulted in distinction of scores between clinical and non-clinical groups and between men and women; the relationship between high scores on the scale T and the other scales; scores of drug users according to the declared used substance; and the relationship between high scores on T and the verification of disorder or risk on GHQ mental health factor, indicating the instrument´s adequate sensistivity in identifying psychopathologies and the relationship between the different disorders or psychopathological personality patterns. Although further studies are necessary to develop the scores transformation factors, the computerized correction tool was adequate.
Resumo:
Esse trabalho objetivou promover a adaptação transcultural para o Brasil da VASS. Os passos para adaptação transcultural seguirão a proposta de operacionalização alicerçado na apreciação de diferentes tipos de equivalência: a conceitual e de itens, a semântica e a de mensuração. Para alcançar as duas primeiras etapas utilizou-se as técnicas de tradução e retrotradução associada ao procedimento intitulado Painel de Especialistas. Para o pré-teste e verificação de equivalência de mensuração, aplicou-se o questionário com uma população de 30 e 66 idosos, respectivamente. Para as análises dos resultados foi utilizada a estatística descritiva e inferencial, em especial o KR-20, teste T de student, correlação de Pearson e ANOVA univariada, bem como o método kappa de Fleiss para verificação do índice de confiabilidade. Verificou-se que o conceito utilizado para construção do instrumento, bem como seus itens se mostram adequados à investigação do fenômeno. Evidenciou-se boa equivalência semântica entre os itens das retrotraduções e do instrumento original, especialmente quanto aos resultados de T1 R1. Os juízes optaram pelo uso de 11 itens de T1 à versão-síntese. A equivalência operacional mostrou-se satisfatória. Em geral, os resultados apresentados mostraram-se aceitáveis. Quanto à etapa da equivalência de mensuração, verificou-se que a idade dos participantes variou entre 60 a 84 anos, prevalecendo respondentes idosas (n = 38), representando 57,6% da amostra estudada. O valor do KR-20 para o escore geral do instrumento foi de 0,688 (IC95%: 0,670). Os valores encontrados para as quatro dimensões propostas pelos autores do estudo inicial do instrumento foram 0,528, 0,289, 0,552 e 0,303, respectivamente. Apenas os valores de consistência interna das subescalas Vulnerabilidade e Coerção mostraram-se aproximados aos encontrados no estudo original, a saber, 0,550 e 0,390, respectivamente. Verificou-se que com a retirada dos itens nº 04, nº 06 e nº 10, houve aumento do índice de consistência interna da escala total. Já quanto aos valores da consistência interna das subescalas, percebeu-se que apenas com a retirada dos itens nº 09, referente à escala que dimensiona o Desânimo, e nº 12, item da subescala Coerção, é que houve acréscimo nesses valores. Destaca-se que esses são resultados preliminares, uma vez que após a verificação da adequabilidade e de padrões psicométricos iniciais acerca do uso do instrumento para a população idosa, ainda há de se dar continuidade à etapa concernente à verificação de propriedades psicométricas robustas do instrumento, que indiquem, por exemplo, evidências de fidedignidade em situação de teste-reteste, validade de constructo e de critério, se possível e aplicável. A principal limitação do estudo é a falta de um instrumento padrão-ouro para testar a fidedignidade, sensibilidade e especificidade do instrumento em questão. Apesar desta limitação, a adaptação transcultural e a verificação de propriedades psicométricas preliminares do instrumento de uma medida de autorrelato que afere indicativo de violência doméstica contra o idoso tem sua relevância e foi satisfatória
Resumo:
The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components
Resumo:
The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology
Resumo:
The calculation of tooth mass discrepancy, essential for good planning and a proper orthodontic finishing, when performed manually, besides being laborious, requires considerable time consumption. The aim of this study was to develop and test Bolton Freeware, a software for analysis of the tooth mass discrepancy of Bolton, aiming to minimize the consumption of time in a less onerous way. The digital analysis of the software was done by means of two-dimensional scanning of plaster study models and compared to manual evaluation (gold standard), using 75 pairs of stone plaster study models divided into two groups according to the magnitude of the Curve of Spee (group I from 0 to 2 mm, group II greater than 2 to 3mm). All the models had permanent dentition and were in perfect condition. The manual evaluation was performed with a digital caliper and a calculator, and the time required to perform the analysis for both methods was recorded and compared. In addition, the software was evaluated by orthodontists regarding its use, by means of questionnaires developed specifically for this purpose. Calibration was performed prior to manual analysis, and excellent levels of inter-rater agreement were achieved, with ICC > 0.75 and r > 0.9 for total and anterior proportion. It was observed in the evaluation of error of the digital method that some teeth showed a significant systematic error, being the highest measured at 0.08 mm. The analysis of total tooth mass discrepancy performed by Bolton Freeware, for those cases in which the curve of Spee is mild and moderate, differ from manual analysis, on average, 0.09 mm and 0.07 mm respectively, for each tooth evaluated, with r> 0, 8 for total and anterior proportion. According to the specificity and sensitivity test, Bolton Freeware has an improved ability to detect true negatives, i.e. the presence of discrepancy. The Bolton analysis digitally performed was faster, with an average difference of time consumed to perform the analysis of Bolton between the two methods of approximately 6 minutes. Most experts interviewed (93%) approved the usability of the software
Resumo:
TEMA: adaptação brasileira da avaliação dos processos de leitura (Prolec). OBJETIVO: caracterizar e comparar o desempenho de escolares do ensino básico público e privado de 1ª a 4ª séries na adaptação brasileira da avaliação dos Processos de Leitura (Prolec). MÉTODO: participaram deste estudo 262 escolares da 1ª à 4ª série do ensino básico, distribuídos em: Grupo I (GI), composto por 122 escolares de escola pública municipal e Grupo II (GII), composto por 140 escolares de escola particular. Como procedimento, aplicou-se a adaptação brasileira das provas de avaliação do Prolec. RESULTADOS: os resultados revelaram que o GII apresentou desempenho superior em provas de identificação de som, decisão lexical, leitura de palavras, leitura de palavras de baixa frequência, leitura de pseudo-palavras, compreensão de orações e compreensão de textos. Tanto os escolares do GI como do GII apresentaram desempenho abaixo da pontuação esperada nas provas do PROLEC na versão espanhola. CONCLUSÃO: a adaptação do Prolec para a realidade brasileira mostrou-se adequada para o estabelecimento de perfil de leitura nos escolares de ensino público e particular em fase inicial de alfabetização.