777 resultados para Coating
Resumo:
Dissertação de natureza científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações
A influência das condições de cura nas propriedades das argamassas de cal para revestimentos antigos
Resumo:
Dissertação elaborada no Laboratório Nacional de Engenharia Civil (LNEC) para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações no âmbito do protocolo de cooperação entre o ISEL e o LNEC
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
Dissertação de Mestrado, Tecnologia e Segurança Alimentar, 12 Fevereiro de 2016, Universidade dos Açores.
Resumo:
The present paper describes a procedure to isolate volatiles from rock-rose (Cistus ladanifer L.) using simultaneous distillation–extraction (SDE). High-value volatile compounds (HVVC) were selected and the influence of the extraction conditions investigated. The effect of the solvent nature and extraction time on SDE efficiency was studied. The best performance was achieved with pentane in 1 h operation. The extraction efficiencies ranged from 65% to 85% and the repeatability varied between 4% and 6% (as a CV%). The C. ladanifer SDE extracts were analysed by headspace solid phase microextraction (HS-SPME) followed by gas chromatography with flame ionization detection (GC-FID). The HS-SPME sampling conditions such as fiber coating, temperature, ionic strength and exposure time were optimized. The best results were achieved with an 85 µm polyacrylate fiber for a 60 min headspace extraction at 40ºC with 20% (w/v) of NaCl. For optimized conditions the recovery was in average higher than 90% for all compounds and the intermediate precision ranged from 4 to 9% (as CV %). The volatiles α-pinene (22.2 mg g−1 of extract), 2,2,6-trimethylcyclohexanone (6.1 mg g−1 of extract), borneol (3.0 mg g−1 of extract) and bornyl acetate (3.9 mg g−1 of extract) were identified in the SDE extracts obtained from the fresh plant material.
Resumo:
Neste trabalho é abordado o estágio efectuado por um período de sete meses na E.A. (Engenheiros Associados) e um estudo de caso sobre as tecnologias aplicadas no isolamento térmico de paredes exteriores. Na primeira parte deste relatório é efectuada uma breve caracterização da empresa e da sua actividade no mercado. A Engenheiros e Associados tem a sua estrutura assente nos seguintes sectores: Técnico-Comercial, de Aprovisionamento e de Gestão Administrativa; da qual foi efectuada uma descrição do trabalho desenvolvido em cada um desses sectores, nomeadamente a permanência na obra e as visitas e diligências às obras. A segunda parte deste relatório, que é a parte fulcral do trabalho desenvolvido, assenta sobre o sistema de ETICS (External Thermal Insulation Composite System), ou seja, o sistema de reboco delgado armado sobre isolamento térmico. Foi utilizado o sistema Cappotto na Obra de Requalificação da Urbanização de Vila d’Este – 1ª Fase. Após uma breve apresentação e evolução da história do ETICS ao longo do tempo, é exposta a caracterização da obra onde vai ser aplicado o sistema, que recai sobre a tipologia dos edifícios. Refira-se que, neste relatório, os edifícios por serem de construção túnel se dividem em três tipos: tipo plana ou corrente, tipo ângulo e tipo topo. Na Analise de Patologias efectuada evidenciam-se as fissuras e a humidade presentes em quase toda a extensão dos referidos edifícios antes do tratamento, tornando-as assim as principais anomalias destes edifícios. Foram elemento de foco as anomalias existentes nos edifícios, como: Deterioração do fibrocimento; Insuficiência das caleiras; Deficiências das impermeabilizações; Ausência de rufos; Deficiência das ligações; Degradação do revestimento e pintura; Fissuração do reboco; Degradação dos forros exteriores; Deterioração das padieiras; Deterioração dos peitoris; Deterioração das juntas de dilatação; Infiltrações e condensações; Ruptura das canalizações; Deslocamentos; Deficiências de ventilação; Deficiências de estanqueidade; Inexistência de Sistema de combate a incêndios. Para estas patologias são apresentadas as propostas de solução de forma a eliminar as mesmas. Sendo o ETICS escolhido por ser o sistema que elimina a maior parte destas patologias, tendo em conta uma relação de qualidade/preço, é abordada de uma forma detalhada e extensiva da aplicação do sistema antes, durante e depois da obra em si. Assim como, é feita uma descrição pormenorizada do material utilizado para a implementação do sistema. A análise dos pontos críticos refere-se a zonas sensíveis onde há a necessidade de reforço do sistema com vista a eliminar o aparecimento posterior de patologias, como por exemplo as características de suporte. Após a aplicação do sistema podem aparecer algumas patologias das quais se destaca o facto dos produtos serem preparados em obra, o erro humano nas dosagens do fabricante e no acrescento de água sem necessidade e a par das condições climatéricas, são as causas mais comuns do aparecimento de anomalias no sistema de ETICS, provocando fissurações e infiltrações, que são descritas neste relatório. É também abordada a manutenção e reparação do sistema, onde a manutenção refere-se à lavagem e à remoção de microorganismos das paredes e posterior pintura. A reparação dos danos divide-se em dois tipos, áreas até 2 cm2 e áreas maiores que 2 cm2. Por fim, são apresentados alguns rendimentos, que foram possíveis obter ao longo do desenvolvimento do trabalho, dos materiais e da mão-de-obra, dando origem aos custos directos. Sendo também abordadas as vantagens e desvantagens do sistema desde o seu início até à sua conclusão.
Resumo:
Atualmente, a escavação de poços em locais densamente ocupados requer medidas severas para reduzir riscos e possíveis influências quer na própria obra quer em estruturas próximas. Neste campo, a instrumentação geotécnica e a sua monitorização tem um papel determinante na execução de obras geotécnicas, sendo que neste trabalho é dado um especial realce à instrumentação utilizada, às atividades de observação geotécnica, bem como à análise e interpretação das leituras para o controlo de movimentos induzidos no terreno pelas escavações. Este acompanhamento é baseado num plano de instrumentação, sendo descrito de uma forma transversal a importância do projeto e em particular das fases do processo de investigação geotécnica. O acompanhamento da execução dos poços para a futura Estação da Reboleira, permitiu validar as soluções de projeto para um determinado método construtivo, determinadas através de métodos numéricos e semi-empíricos, e abordados neste trabalho. A monitorização sistemática desde o início das escavações até ao revestimento secundário, permitiu tecer apreciações sobre os valores obtidos, apresentando-se alguns registos. Todas estas ações visam controlar e antecipar riscos de acidentes provocados pela execução de escavações, pelo que nesta tese é também realçada a importância da segurança e higiene no trabalho na prevenção dos riscos profissionais, independentemente da sua origem.
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Civil
Resumo:
Titanium Diboride (TiB2) presents high mechanical and physical properties. Some wear studies were also carried out in order to evaluate its tribological properties. One of the most popular wear tests for thin films is the ball-cratering configuration. This work was focused on the study of the tribological properties of TiB2 thin films using micro-abrasion tests and following the BS EN 1071-6: 2007 standard. Due to high hardness usually patented by these films, diamond was selected as abrasive on micro-abrasion tests. Micro-abrasion wear tests were performed under five different durations, using the same normal load, speed rotation and ball. Films were deposited by unbalanced magnetron sputtering Physical Vapour Deposition (PVD) technique using TiB2 targets. TiB2 films were characterized using different methods as Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Atomic Force Microscopy (AFM), X-ray Diffraction (XRD), Electron Probe Micro-Analyser (EPMA), Ultra Micro Hardness and Scratch-test Analysis, allowing to confirm that TiB2 presents adequate mechanical and physical properties. Ratio between hardness (coating and abrasive particles), wear resistance and wear coefficient were studied, showing that TiB2 films shows excellent properties for tribological applications.
Resumo:
Cost-effective glass-reinforced thermoplastic matri x towpregs produced by a powder coating line were used to manufacture composite pipes by fi lament winding. A conventional 6 axes filament-winding equipment was adapted for processi ng such structures. The influence of the filament winding speed and mandrel temperature on t he composite final properties was studied in the present work. An optimized processin g window was established by comparing the composite theoretical expected mechanical prope rties with the experimentally obtained ones. The final properties determined on the produc ed pipes and structures and the technological changes introduced to the conventiona l filament-winding equipment will be presented and discussed. Besides the processing des cription and conditions, it will be presented the relationship between processing condi tions and mechanical properties.
Resumo:
Towpregs based on different fibres and thermoplastic matrices were processed for highly demanding and more commercial applications by different composite processing technologies. In the technologies used, compression moulding and pultrusion, the final composite pr ocessing parameters were studied in order to obtain composites with adequate properties at industrial compatible production rates. The produced towpregs were tested to verify its polymer content and degree of impregnation. The obtained results have shown t hat the coating line enabled to produce, with efficiency and industrial scale speed rates, thermoplastic matrix towpregs that may be used to manufacture composites for advanced and larger volume commercial markets.
Resumo:
Dissertação apresentada para a obtenção do grau de Doutor em Engenharia Química, especialidade Engenharia da Reacção Química, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.
Resumo:
Abrasion by glass fibers during injection molding of fiber reinforced plastics raises new challenges to the wear performance of the molds. In the last few decades, a large number of PVD and CVD coatings have been developed with the aim of minimizing abrasion problems. In this work, two different coatings were tested in order to increase the wear resistance of the surface of a mold used for glass fiber reinforced plastics: TiAlSiN and CrN/CrCN/DLC. TiAlSiN was deposited as a graded monolayer coating while CrN/CrCN/DLC was a nanostructured coating consisting of three distinct layers. Both coatings were produced by PVD unbalanced magnetron sputtering and were characterized using scanning electron microscopy (SEM) provided with energy dispersive spectroscopy (EDS), atomic force microscopy (AFM), micro hardness (MH) and scratch test analysis. Coating morphology, thickness, roughness, chemical composition and structure, hardness and adhesion to the substrate were investigated. Wear resistance was characterized through industrial tests with coated samples and an uncoated reference sample inserted in a feed channel of a plastic injection mold working with 30 wt.% glass fiber reinforced polypropylene. Results after 45,000 injection cycles indicate that the wear resistance of the mold was increased by a factor of 25 and 58, by the TiAlSiN and CrN/CrCN/DLC coatings, respectively, over the uncoated mold steel.
Resumo:
Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.