921 resultados para test development
Resumo:
Atherosclerosis is a chronic cardiovascular disease that involves the thicken¬ing of the artery walls as well as the formation of plaques (lesions) causing the narrowing of the lumens, in vessels such as the aorta, the coronary and the carotid arteries. Magnetic resonance imaging (MRI) is a promising modality for the assessment of atherosclerosis, as it is a non-invasive and patient-friendly procedure that does not use ionizing radiation. MRI offers high soft tissue con¬trast already without the need of intravenous contrast media; while modifica¬tion of the MR pulse sequences allows for further adjustment of the contrast for specific diagnostic needs. As such, MRI can create angiographic images of the vessel lumens to assess stenoses at the late stage of the disease, as well as blood flow-suppressed images for the early investigation of the vessel wall and the characterization of the atherosclerotic plaques. However, despite the great technical progress that occurred over the past two decades, MRI is intrinsically a low sensitive technique and some limitations still exist in terms of accuracy and performance. A major challenge for coronary artery imaging is respiratory motion. State- of-the-art diaphragmatic navigators rely on an indirect measure of motion, per¬form a ID correction, and have long and unpredictable scan time. In response, self-navigation (SM) strategies have recently been introduced that offer 100% scan efficiency and increased ease of use. SN detects respiratory motion di¬rectly from the image data obtained at the level of the heart, and retrospectively corrects the same data before final image reconstruction. Thus, SN holds po-tential for multi-dimensional motion compensation. To this regard, this thesis presents novel SN methods that estimate 2D and 3D motion parameters from aliased sub-images that are obtained from the same raw data composing the final image. Combination of all corrected sub-images produces a final image with reduced motion artifacts for the visualization of the coronaries. The first study (section 2.2, 2D Self-Navigation with Compressed Sensing) consists of a method for 2D translational motion compensation. Here, the use of com- pressed sensing (CS) reconstruction is proposed and investigated to support motion detection by reducing aliasing artifacts. In healthy human subjects, CS demonstrated an improvement in motion detection accuracy with simula¬tions on in vivo data, while improved coronary artery visualization was demon¬strated on in vivo free-breathing acquisitions. However, the motion of the heart induced by respiration has been shown to occur in three dimensions and to be more complex than a simple translation. Therefore, the second study (section 2.3,3D Self-Navigation) consists of a method for 3D affine motion correction rather than 2D only. Here, different techniques were adopted to reduce background signal contribution in respiratory motion tracking, as this can be adversely affected by the static tissue that surrounds the heart. The proposed method demonstrated to improve conspicuity and vi¬sualization of coronary arteries in healthy and cardiovascular disease patient cohorts in comparison to a conventional ID SN method. In the third study (section 2.4, 3D Self-Navigation with Compressed Sensing), the same tracking methods were used to obtain sub-images sorted according to the respiratory position. Then, instead of motion correction, a compressed sensing reconstruction was performed on all sorted sub-image data. This process ex¬ploits the consistency of the sorted data to reduce aliasing artifacts such that the sub-image corresponding to the end-expiratory phase can directly be used to visualize the coronaries. In a healthy volunteer cohort, this strategy improved conspicuity and visualization of the coronary arteries when compared to a con¬ventional ID SN method. For the visualization of the vessel wall and atherosclerotic plaques, the state- of-the-art dual inversion recovery (DIR) technique is able to suppress the signal coming from flowing blood and provide positive wall-lumen contrast. How¬ever, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. In response and as a fourth study of this thesis (chapter 3, Vessel Wall MRI of the Carotid Arteries), a phase-sensitive DIR method has been implemented and tested in the carotid arteries of a healthy volunteer cohort. By exploiting the phase information of images acquired after DIR, the proposed phase-sensitive method enhances wall-lumen contrast while widens the window of opportunity for image acquisition. As a result, a 3-fold increase in volumetric coverage is obtained at no extra cost in scanning time, while image quality is improved. In conclusion, this thesis presented novel methods to address some of the main challenges for MRI of atherosclerosis: the suppression of motion and flow artifacts for improved visualization of vessel lumens, walls and plaques. Such methods showed to significantly improve image quality in human healthy sub¬jects, as well as scan efficiency and ease-of-use of MRI. Extensive validation is now warranted in patient populations to ascertain their diagnostic perfor¬mance. Eventually, these methods may bring the use of atherosclerosis MRI closer to the clinical practice. Résumé L'athérosclérose est une maladie cardiovasculaire chronique qui implique le épaississement de la paroi des artères, ainsi que la formation de plaques (lé¬sions) provoquant le rétrécissement des lumières, dans des vaisseaux tels que l'aorte, les coronaires et les artères carotides. L'imagerie par résonance magné¬tique (IRM) est une modalité prometteuse pour l'évaluation de l'athérosclérose, car il s'agit d'une procédure non-invasive et conviviale pour les patients, qui n'utilise pas des rayonnements ionisants. L'IRM offre un contraste des tissus mous très élevé sans avoir besoin de médias de contraste intraveineux, tan¬dis que la modification des séquences d'impulsions de RM permet en outre le réglage du contraste pour des besoins diagnostiques spécifiques. À ce titre, l'IRM peut créer des images angiographiques des lumières des vaisseaux pour évaluer les sténoses à la fin du stade de la maladie, ainsi que des images avec suppression du flux sanguin pour une première enquête des parois des vais¬seaux et une caractérisation des plaques d'athérosclérose. Cependant, malgré les grands progrès techniques qui ont eu lieu au cours des deux dernières dé¬cennies, l'IRM est une technique peu sensible et certaines limitations existent encore en termes de précision et de performance. Un des principaux défis pour l'imagerie de l'artère coronaire est le mou¬vement respiratoire. Les navigateurs diaphragmatiques de pointe comptent sur une mesure indirecte de mouvement, effectuent une correction 1D, et ont un temps d'acquisition long et imprévisible. En réponse, les stratégies d'auto- navigation (self-navigation: SN) ont été introduites récemment et offrent 100% d'efficacité d'acquisition et une meilleure facilité d'utilisation. Les SN détectent le mouvement respiratoire directement à partir des données brutes de l'image obtenue au niveau du coeur, et rétrospectivement corrigent ces mêmes données avant la reconstruction finale de l'image. Ainsi, les SN détiennent un poten¬tiel pour une compensation multidimensionnelle du mouvement. A cet égard, cette thèse présente de nouvelles méthodes SN qui estiment les paramètres de mouvement 2D et 3D à partir de sous-images qui sont obtenues à partir des mêmes données brutes qui composent l'image finale. La combinaison de toutes les sous-images corrigées produit une image finale pour la visualisation des coronaires ou les artefacts du mouvement sont réduits. La première étude (section 2.2,2D Self-Navigation with Compressed Sensing) traite d'une méthode pour une compensation 2D de mouvement de translation. Ici, on étudie l'utilisation de la reconstruction d'acquisition comprimée (compressed sensing: CS) pour soutenir la détection de mouvement en réduisant les artefacts de sous-échantillonnage. Chez des sujets humains sains, CS a démontré une amélioration de la précision de la détection de mouvement avec des simula¬tions sur des données in vivo, tandis que la visualisation de l'artère coronaire sur des acquisitions de respiration libre in vivo a aussi été améliorée. Pourtant, le mouvement du coeur induite par la respiration se produit en trois dimensions et il est plus complexe qu'un simple déplacement. Par conséquent, la deuxième étude (section 2.3, 3D Self-Navigation) traite d'une méthode de cor¬rection du mouvement 3D plutôt que 2D uniquement. Ici, différentes tech¬niques ont été adoptées pour réduire la contribution du signal du fond dans le suivi de mouvement respiratoire, qui peut être influencé négativement par le tissu statique qui entoure le coeur. La méthode proposée a démontré une amélioration, par rapport à la procédure classique SN de correction 1D, de la visualisation des artères coronaires dans le groupe de sujets sains et des pa¬tients avec maladies cardio-vasculaires. Dans la troisième étude (section 2.4,3D Self-Navigation with Compressed Sensing), les mêmes méthodes de suivi ont été utilisées pour obtenir des sous-images triées selon la position respiratoire. Au lieu de la correction du mouvement, une reconstruction de CS a été réalisée sur toutes les sous-images triées. Cette procédure exploite la cohérence des données pour réduire les artefacts de sous- échantillonnage de telle sorte que la sous-image correspondant à la phase de fin d'expiration peut directement être utilisée pour visualiser les coronaires. Dans un échantillon de volontaires en bonne santé, cette stratégie a amélioré la netteté et la visualisation des artères coronaires par rapport à une méthode classique SN ID. Pour la visualisation des parois des vaisseaux et de plaques d'athérosclérose, la technique de pointe avec double récupération d'inversion (DIR) est capa¬ble de supprimer le signal provenant du sang et de fournir un contraste posi¬tif entre la paroi et la lumière. Pourtant, il est difficile d'obtenir un contraste optimal car cela est soumis à la variabilité du rythme cardiaque. Par ailleurs, l'imagerie DIR est inefficace du point de vue du temps et les acquisitions "mul- tislice" peuvent conduire à des temps de scan prolongés. En réponse à ce prob¬lème et comme quatrième étude de cette thèse (chapitre 3, Vessel Wall MRI of the Carotid Arteries), une méthode de DIR phase-sensitive a été implémenté et testé
Resumo:
Tutkimuksen tavoitteena oli selvittää miten kehittää yrityksen nykyistä e-palvelujärjestelmää, Internet -teknologiaan perustuvaa sähköisiä kommunikaatio- ja tiedonjakojärjestelmää, yrityksen business-to-business asiakkuuksien johtamisessa. Tavoitteena oli myös luoda ehdotukset uusista e-palvelusopimusmalleista. Tutkimuksen teoriaosuudessa pyrittiin kehittämään aikaisempiin tutkimuksiin, tietokirjallisuuteen ja asiantuntijoihin perustuva viitekehysmalli. Empiirisessä osassa tutkimuksen tavoitteisiin pyrittiin haastattelemalla yrityksen asiakkaita ja henkilöstöä, sekä tarkastelemalla asiakaskontaktien nykyistä tilaa ja kehittymistä. Näiden tietojen perusteella selvitettiin e-palvelun käyttäjien tarpeita, profiilia ja valmiuksia palvelun käyttöön sekä palvelun nykyistä houkuttelevuutta. Tutkimuksen teoriaosan lähdeaineistona käytettiin kirjallisuutta, artikkeleita ja tilastoja asiakashallinnasta sekä e-palveluiden, erityisesti Internet ja verkkopalveluiden markkinoinnista, nykytilasta sekä palveluiden kehittämisestä. Lisäksi tutkittiin kirjallisuutta arvoverkostoanalyysistä, asiakkaan arvosta, informaatioteknologiasta, palvelun laadusta ja asiakastyytyväisyydestä. Tutkimuksen empiirinen osa perustuu yrityksen henkilöstöltä sekä asiakkailta haastatteluissa kerättyihin tietoihin, yrityksen ennalta keräämiin materiaaleihin sekä Taloustutkimuksen keräämiin tietoihin. Tutkimuksessa käytettiin case -menetelmää, joka oli yhdistelmä sekä kvalitatiivista että kvantitatiivista tutkimusta. Casen tarkoituksena oli testata mallin paikkansapitävyyttä ja käyttökelpoisuutta, sekä selvittää onko olemassa vielä muita tekijöitä, jotka vaikuttavat asiakkaan saamaan arvoon. Kvalitatiivinen aineisto perustuu teemahaastattelumenetelmää soveltaen haastateltuihin asiakkaisiin ja yrityksen työntekijöihin. Kvantitatiivinen tutkimus perustuu Taloustutkimuksen tutkimukseen ja yrityksen asiakaskontakteista kerättyyn tietoon. Haastatteluiden perusteella e-palvelut nähtiin hyödyllisinä ja tulevaisuudessa erittäin tärkeinä. E-palvelut nähdään yhtenä tärkeänä kanavana, perinteisten kanavien rinnalla, tehostaa business-to-business -asiakkuuksien johtamista. Tutkimuksen antamien tulosten mukaan asiakkaiden palveluun liittyvän tieto-, taito-, tarpeellisuus- ja kiinnostavuustasojen vaihtelevaisuus osoittaa selvän tarpeen eritasoisille e-palvelupaketti ratkaisuille. Tuloksista muodostettu ratkaisuehdotus käsittää neljän eri e-palvelupaketin rakentamisen asiakkaiden eri tarpeita mukaillen.
Resumo:
The GH-2000 and GH-2004 projects have developed a method for detecting GH misuse based on measuring insulin-like growth factor-I (IGF-I) and the amino-terminal pro-peptide of type III collagen (P-III-NP). The objectives were to analyze more samples from elite athletes to improve the reliability of the decision limit estimates, to evaluate whether the existing decision limits needed revision, and to validate further non-radioisotopic assays for these markers. The study included 998 male and 931 female elite athletes. Blood samples were collected according to World Anti-Doping Agency (WADA) guidelines at various sporting events including the 2011 International Association of Athletics Federations (IAAF) World Athletics Championships in Daegu, South Korea. IGF-I was measured by the Immunotech A15729 IGF-I IRMA, the Immunodiagnostic Systems iSYS IGF-I assay and a recently developed mass spectrometry (LC-MS/MS) method. P-III-NP was measured by the Cisbio RIA-gnost P-III-P, Orion UniQ? PIIINP RIA and Siemens ADVIA Centaur P-III-NP assays. The GH-2000 score decision limits were developed using existing statistical techniques. Decision limits were determined using a specificity of 99.99% and an allowance for uncertainty because of the finite sample size. The revised Immunotech IGF-I - Orion P-III-NP assay combination decision limit did not change significantly following the addition of the new samples. The new decision limits are applied to currently available non-radioisotopic assays to measure IGF-I and P-III-NP in elite athletes, which should allow wider flexibility to implement the GH-2000 marker test for GH misuse while providing some resilience against manufacturer withdrawal or change of assays. Copyright © 2015 John Wiley & Sons, Ltd.
Resumo:
OBJECTIVE: To review the available knowledge on epidemiology and diagnoses of acute infections in children aged 2 to 59 months in primary care setting and develop an electronic algorithm for the Integrated Management of Childhood Illness to reach optimal clinical outcome and rational use of medicines. METHODS: A structured literature review in Medline, Embase and the Cochrane Database of Systematic Review (CDRS) looked for available estimations of diseases prevalence in outpatients aged 2-59 months, and for available evidence on i) accuracy of clinical predictors, and ii) performance of point-of-care tests for targeted diseases. A new algorithm for the management of childhood illness (ALMANACH) was designed based on evidence retrieved and results of a study on etiologies of fever in Tanzanian children outpatients. FINDINGS: The major changes in ALMANACH compared to IMCI (2008 version) are the following: i) assessment of 10 danger signs, ii) classification of non-severe children into febrile and non-febrile illness, the latter receiving no antibiotics, iii) classification of pneumonia based on a respiratory rate threshold of 50 assessed twice for febrile children 12-59 months; iv) malaria rapid diagnostic test performed for all febrile children. In the absence of identified source of fever at the end of the assessment, v) urine dipstick performed for febrile children <2 years to consider urinary tract infection, vi) classification of 'possible typhoid' for febrile children >2 years with abdominal tenderness; and lastly vii) classification of 'likely viral infection' in case of negative results. CONCLUSION: This smartphone-run algorithm based on new evidence and two point-of-care tests should improve the quality of care of <5 year children and lead to more rational use of antimicrobials.
Resumo:
Business process improvement is a common approach in increasing the effectiveness of an organization. It can be seen as an effort to increase coordination between units. Process improvement has proved to be challenging, and most management consultation firms facilitate organizations in this kind of initiatives. Cross-functional improvement is one of the main areas for internal consultants as well. However, the needs, challenges and means of cross-functional help have been rarely discussed in the literature. The objective of this thesis is on one hand to present a conceptual and descriptive framework to help understand the challenges of facilitating coordination improvement efforts in cross-functional improvement programs, and on the other hand to develop and test feasible solutions for some facilitation situations. The research questions are: 1. Why and in what kind of situations do organizations need help in developing coordination in cross-functional processes? 2. How can a facilitator help organizations in improving coordination to develop cross-functional processes? The study consists of two parts. The first part is an overview of the dissertation, and the second part comprises six research publications. The theoretical background for the study are the differentiation causing challenges in cross-functional settings, the coordination needed to improve processes, change management principles, methods and tools, and consultation practises. Three of the publications introduce tools for helping in developing prerequisites, planning responsibilities and supporting learning during the cross-functional program. The three other papers present frameworks to help understand and analyse the improvement situation. The main methodological approaches used in this study are design science research, action research and case research. The research data has been collected from ten cases representing different kinds of organizations, processes and developing situations. The data has been collected mainly by observation, semi-structured interviews and questionnaires. The research contributes to the rare literature combining coordination theories and process improvement practises. It also provides additional understanding of a holistic point of view in process improvement situations. The most important contribution is the addition to the theories of facilitating change in process improvement situations. From the managerial point of view, this study gives advice to managers and consultants in planning and executing cross-functional programs. The main factors increasing the need for facilitation are the challenges for differentiation, challenges of organizational change in general, and the novelty of initiatives and improvement practices concerning process development. Organizations need help in creating the prerequisites to change, in planning initiatives, easing conflict management and collaboration between groups, as well as supporting the learning of cross-functional improvement. The main challenges of facilitation are combining the different roles as a consultant, maintaining the ownership for the improvement project with the client, and supporting learning in the client organization.
Resumo:
AIM: To develop and test the Parental PELICAN Questionnaire, an instrument to retrospectively assess parental experiences and needs during their child's end-of-life care. BACKGROUND: To offer appropriate care for dying children, healthcare professionals need to understand the illness experience from the family perspective. A questionnaire specific to the end-of-life experiences and needs of parents losing a child is needed to evaluate the perceived quality of paediatric end-of-life care. DESIGN: This is an instrument development study applying mixed methods based on recommendations for questionnaire design and validation. METHOD: The Parental PELICAN Questionnaire was developed in four phases between August 2012-March 2014: phase 1: item generation; phase 2: validity testing; phase 3: translation; phase 4: pilot testing. Psychometric properties were assessed after applying the Parental PELICAN Questionnaire in a sample of 224 bereaved parents in April 2014. Validity testing covered the evidence based on tests of content, internal structure and relations to other variables. RESULTS: The Parental PELICAN Questionnaire consists of approximately 90 items in four slightly different versions accounting for particularities of the four diagnostic groups. The questionnaire's items were structured according to six quality domains described in the literature. Evidence of initial validity and reliability could be demonstrated with the involvement of healthcare professionals and bereaved parents. CONCLUSION: The Parental PELICAN Questionnaire holds promise as a measure to assess parental experiences and needs and is applicable to a broad range of paediatric specialties and settings. Future validation is needed to evaluate its suitability in different cultures.
Resumo:
Objective - To describe the global and language development of children with cleft palate or cleft lip and palate at the age of 18 months, and to evaluate whether the type of cleft has an impact on psychomotor development. Study Design - Prospective cohort study. Settings - Tertiary care hospital Patients - All children born between December 2002 and November 2009 with an orofacial cleft, operated and seen at the developmental unit (UD) of the same hospital at the age of 18 months. Outcome Measures - Developmental quotients of the Griffiths Mental Development Scale and the French Communicative Development Inventory (IFDC) were used to assess the overall and language development of the children. Statistics- The population characteristics were described with means for continuous variables, and frequencies for binary or categorical variables. Chi-squared and regression analysis were used to analyse the results. Results - 69 children with clefts were examined at the age of 18 months with the IFDC and the Griffith test. The results showed that there was no significant difference in the test results of language development and global psychomotor development between the children with different types of clefts, and all were within the normal range. Conclusion - Psychomotor development is not affected by orofacial clefts, and there is no difference between children with cleft palate or cleft lip and palate.
Resumo:
The purpose of this work was to study the characteristics of the most commonly used filter aid materials and their influences on the design of proportioning, mixing, and feeding system for polishing filter family. Based on the literature survey and hands-on experience a system was designed with defined equipment and capital and operating costs. The system was designed to serve precoating and bodyfeeding applications and is easily extended to be used in multiple filter processes. Also a test procedure was carried out where influences of flux and filter cloths to accumulated cake were studied. Filter aid is needed in challenging conditions to improve filtration efficiency and cleaning, and thus extend the operating life of the filter media. Filter aid preparation and feeding system was designed for the use of two different filter aids; precoat and bodyfeed. Precoating is used before the filtration step initiates. If the solids in the filterable solution have a tendency to clog the filter bag easily, precoat is used on the filter bag to obtain better filtration efficiency and quality. Diatomite or perlite is usually used as a precoating substance. The intention is to create a uniform cake to the overall surface of the filter cloth, with predetermined thickness, 2 – 5 mm. This ensures that the clogging of the filter cloth is reduced and the filtration efficiency is increased. Bodyfeed is used if the solids in the filterable solution have a tendency to form a sticky impermeable filter cake. The cake properties are enhanced by maintaining the permeability of the accumulating cake by using the filter aid substance as bodyfeed during the filtration process.
Resumo:
A simple and rapid precipitation titration method was developed and validated to determine sulfate ion content in indinavir sulfate raw material. 0.1 mol L-1 lead nitrate volumetric solution was used as titrant employing potentiometric endpoint determination using a lead-specific electrode. The United States Pharmacopoeia Forum indicates a potentiometric method for sulfate ion quantitation using 0.1 mol L-1 lead perchlorate as titrant. Both methods were validated concerning linearity, precision and accuracy, yielding good results. The sulfate ion content found by the two validated methods was compared by the statistical t-student test, indicating that there was no statistically significant difference between the methods.
Resumo:
Aim: To investigate and understand patient's satisfaction with nursing care in the intensive care unit to identify the dimensions of the concept of"satisfaction" from the patient's point of view. To design and validate a questionnaire that measures satisfaction levels in critical patients. Background: There are many instruments capable of measuring satisfaction with nursing care; however, they do not address the reality for critical patients nor are they applicable in our context. Design: A dual approach study comprising: a qualitative phase employing Grounded Theory and a quantitative and descriptive phase to prepare and validate the questionnaire. Methods: Data collection in the qualitative phase will consist of: in-depth interview after theoretical sampling, on-site diary and expert discussion group. The sample size will depend on the expected theoretical saturation n = 27-36. Analysis will be based on Grounded Theory. For the quantitative phase, the sampling will be based on convenience (n = 200). A questionnaire will be designed on the basis of qualitative data. Descriptive and inferential statistics will be used. The validation will be developed on the basis of the validity of the content, the criteria of the construct and reliability of the instrument by the Cronbach's alpha and test-retest approach. Approval date for this protocol was November 2010. Discussion: Self-perceptions, beliefs, experiences, demographic, socio-cultural epistemological and political factors are determinants for satisfaction, and these should be taken into account when compiling a questionnaire on satisfaction with nursing care among critical patients.
Resumo:
This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.
Resumo:
An efficient flotation method based on the combination of flame atomic absorption spectrometry (FAAS) and separation and preconcentration step for determination of Cr3+, Cu 2+, Co2+, Ni2+, Zn2+, Cd 2+, Fe3+ and Pb2+ ions in various real samples by the possibility of applying bis(2-hydroxyacetophenone)-1,4-butanediimine (BHABDI) as a new collector was studied. The influence of pH, amount of BHABDI as collector, sample matrix, type and amount of eluting agent, type and amount of surfactant as floating agent, ionic strength and air flow rates i.e. variables affecting the efficiency of the extraction system was evaluated. It is ascertained that metal ions such as iron can be separated simultaneously from matrix in the presence of 0.012 mM ligand, 0.025% (w/v) of CTAB to a test sample of 750 mL at pH 6.5. These ions can be eluted quantitatively with 6 mL of 1.0 mol L-1 HNO3 in methanol which lead to the enrichment factor of 125. The detection limits for analyte ions were in the range of 1.3-2.4 ng mL-1. The method has been successfully applied for determination of trace amounts of ions in various real samples.
Resumo:
A method using liquid chromatography has been developed and validated for determination of buclizine in pharmaceutical formulations and in release studies. Isocratic chromatography was performed on a C18 column with methanol:water (80:20 v/v, pH 2.6) as mobile phase, at a flow rate of 1.0 mL/min, and UV detection at 230 nm. The method was linear, accurate, precise, sensible and robust. The dissolution test was optimized and validated in terms of dissolution medium, apparatus agitation and rotation speed. The presented analytical and dissolution procedures can be conveniently adopted in the quality and stability control of buclizine in tablets and oral suspension.
Resumo:
A UV-spectrophotometric method is described for the determination of lansoprazole (LAN). The method is based on the measurement of the absorbance of LAN solution in acetonitrile at 281 nm. The system obeyed Beer's law over the concentration range of 1.25-25.0 µg/mL. The degradation behavior of LAN was investigated under dry heat treatment, UV-degradation, acid hydrolysis, alkali hydrolysis and oxidation; and found to degrade extensively under acid hydrolysis, alkali hydrolysis and oxidation. The method was applied to the determination of LAN in capsule and the results were statistically compared with those of the reference method by applying Student's t-test and F-test.
Resumo:
Modern sophisticated telecommunication devices require even more and more comprehensive testing to ensure quality. The test case amount to ensure well enough coverage of testing has increased rapidly and this increased demand cannot be fulfilled anymore only by using manual testing. Also new agile development models require execution of all test cases with every iteration. This has lead manufactures to use test automation more than ever to achieve adequate testing coverage and quality. This thesis is separated into three parts. Evolution of cellular networks is presented at the beginning of the first part. Also software testing, test automation and the influence of development model for testing are examined in the first part. The second part describes a process which was used to implement test automation scheme for functional testing of LTE core network MME element. In implementation of the test automation scheme agile development models and Robot Framework test automation tool were used. In the third part two alternative models are presented for integrating this test automation scheme as part of a continuous integration process. As a result, the test automation scheme for functional testing was implemented. Almost all new functional level testing test cases can now be automated with this scheme. In addition, two models for integrating this scheme to be part of a wider continuous integration pipe were introduced. Also shift from usage of a traditional waterfall model to a new agile development based model in testing stated to be successful.