999 resultados para bread quality
Resumo:
OBJECTIVE: To analyze whether quality of life in active, healthy elderly individuals is influenced by functional status and sociodemographic characteristics, as well as psychological parameters. METHODS: Study conducted in a sample of 120 active elderly subjects recruited from two open universities of the third age in the cities of São Paulo and São José dos Campos (Southeastern Brazil) between May 2005 and April 2006. Quality of life was measured using the abbreviated Brazilian version of the World Health Organization Quality of Live (WHOQOL-bref) questionnaire. Sociodemographic, clinical and functional variables were measured through crossculturally validated assessments by the Mini Mental State Examination, Geriatric Depression Scale, Functional Reach, One-Leg Balance Test, Timed Up and Go Test, Six-Minute Walk Test, Human Activity Profile and a complementary questionnaire. Simple descriptive analyses, Pearson's correlation coefficient, Student's t-test for non-related samples, analyses of variance, linear regression analyses and variance inflation factor were performed. The significance level for all statistical tests was set at 0.05. RESULTS: Linear regression analysis showed an independent correlation without colinearity between depressive symptoms measured by the Geriatric Depression Scale and four domains of the WHOQOL-bref. Not having a conjugal life implied greater perception in the social domain; developing leisure activities and having an income over five minimum wages implied greater perception in the environment domain. CONCLUSIONS: Functional status had no influence on the Quality of Life variable in the analysis models in active elderly. In contrast, psychological factors, as assessed by the Geriatric Depression Scale, and sociodemographic characteristics, such as marital status, income and leisure activities, had an impact on quality of life.
Resumo:
The scientific evidence supporting the management of the chronically ill in a positive psychological perspective in opposition to traditional pathological approach is scarce. This study examines issues associated with recovery of health status in heart failure, in particular hope, affection, and happiness. We use a longitudinal study of 128 symptomatic patients who after medical intervention reported improved quality of life and function at 3-month follow-up. We evaluated the contribution of happiness, hope and affection, individually and as a whole, in the quality of life and functionality of individuals with heart failure. Happiness (Subjective Happiness Scale), Hope (HOPE Scale), and affection (PANAS (positive and negative affect schedule)) were determined before medical intervention. Individually, we found that happiness is correlated with the quality of life and functionality, hope to self-efficacy dimension of the quality of life scale, positive affect to functionality and negative affect with symptoms dimension, quality of life dimension, and overall sum of the quality of life scale. Overall, we found that happiness has a unique contribution to the quality of life, except in self-efficacy dimension where hope takes this contribution and positive affect has a unique contribution to the functionality in this short-term follow-up. The results highlight the importance of positive variables to health outcomes for people with heart failure and should be considered in intervention programs for this syndrome.
Resumo:
Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.
Resumo:
Dissertação de Mestrado, Estudos Integrados dos Oceanos, 15 de Março de 2016, Universidade dos Açores.
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality perception for chest X-ray images. Methods - Bandura's theory was used to guide scale development. A review of the literature was undertaken to identify items/factors which could be used to evaluate image quality using a perceptual approach. A draft scale was then created (22 items) and presented to a focus group (student and qualified radiographers). Within the focus group the draft scale was discussed and modified. A series of seven postero-anterior chest images were generated using a phantom with a range of image qualities. Image quality perception was confirmed for the seven images using signal-to-noise ratio (SNR 17.2–36.5). Participants (student and qualified radiographers and radiology trainees) were then invited to independently score each of the seven images using the draft image quality perception scale. Cronbach alpha was used to test interval reliability. Results - Fifty three participants used the scale to grade image quality perception on each of the seven images. Aggregated mean scale score increased with increasing SNR from 42.1 to 87.7 (r = 0.98, P < 0.001). For each of the 22 individual scale items there was clear differentiation of low, mid and high quality images. A Cronbach alpha coefficient of >0.7 was obtained across each of the seven images. Conclusion - This study represents the first development of a chest image quality perception scale based on Bandura's theory. There was excellent correlation between the image quality perception scores derived using the scale and the SNR. Further research will involve a more detailed item and factor analysis.
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Aim - A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods - Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results - Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p = 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion - For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality.
Resumo:
OBJECTIVE: To evaluate working conditions associated with health-related quality of life (HRQL) among nursing providers. METHODS: Cross-sectional study conducted in a university hospital in the city of São Paulo, Southeastern Brazil, during 2004-2005. The study sample comprised 696 registered nurses, nurse technicians and nurse assistants, predominantly females (87.8%), who worked day and/or night shifts. Data on sociodemographic information, working and living conditions, lifestyles, and health symptoms were collected using self-administered questionnaires. The following questionnaires were also used: Job Stress Scale, Effort-Reward Imbalance (ERI) and Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36). Ordinal logistic regression analysis using proportional odds model was performed to evaluate each dimension of the SF-36. RESULTS: Around 22% of the sample was found to be have high strain and 8% showed an effort-reward imbalance at work. The dimensions with the lowest mean scores in the SF-36 were vitality, bodily pain and mental health. High-strain job, effort-reward imbalance (ERI>1.01), and being a registered nurse were independently associated with low scores on the role emotional dimension. Those dimensions associated to mental health were the ones most affected by psychosocial factors at work. CONCLUSIONS: Effort-reward imbalance was more associated with health than high-strain (high demand and low control). The study results suggest that the joint analysis of psychosocial factors at work such as effort-reward imbalance and demand-control can provide more insight to the discussion of professional roles, working conditions and HRQL of nursing providers.
Resumo:
Objetivo: o otimismo tem sido demonstrado como uma variável importante no ajustamento da qualidade de vida de pessoas com doenças crônicas. O estudo tem como objetivo verificar se o otimismo exerce um efeito moderador ou mediador entre os traços de personalidade e a qualidade de vida, em portugueses com doenças crônicas. Métodos: os modelos de regressão linear múltipla foram usados para avaliar o efeito de moderação e mediação do otimismo na qualidade de vida. A amostra, constituída por 729 doentes, recrutados nos principais hospitais de Portugal responderam a questionários de autorresposta avaliando questões sócio-demográficas e clínicas, personalidade, otimismo disposicional, qualidade de vida e bem-estar subjetivo. Resultados: os resultados encontrados mostraram que o otimismo disposicional não exerce um papel moderador entre os traços de personalidade e a qualidade de vida. Controlando por idade, sexo, nível de escolaridade e percepção da severidade da doença, o efeito dos traços de personalidade na qualidade de vida e no bem-estar subjetivo foi mediado pelo otimismo (parcial e total), expecto para as associações, neuroticismo/abertura à experiência e à saúde física. Conclusão: o otimismo disposicional exerce apenas um papel mediador entre os traços de personalidade e qualidade de vida, em pessoas com doenças crônicas, sugerindo que 'a expectativa de que coisas boas vão acontecer' contribui para uma melhor qualidade de vida e melhor bem-estar subjetivo.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.
Resumo:
The occurrence of OTA in fresh and packed wheat and in maize bread and the evaluation of the exposure degree through their consumption in two Portuguese populations from Porto and Coimbra, during the winter of 2007, were studied. One hundred and sixty eight bread samples, 61 maize and 107 wheat, were analysed by liquid chromatography–fluorescence detection (LC–FD). The results showed that 84% of samples were contaminated, with a maximum level of 3.85 ng/g (above the EU maximum limit, 3 ng/g). Fresh wheat bread presented higher levels than packed wheat bread. Moreover, the traditional maize bread, in either city, was consistently more contaminated than wheat bread, 0.25 vs 0.19 ng/g, and 0.48 vs 0.34 ng/ g for Porto and Coimbra, respectively. Avintes maize bread showed the highest mean contamination and maximum levels. The higher estimated daily intake of OTA from both types of bread in the population of Coimbra compared to Porto reflects the higher average contamination of bread in the first city.
Resumo:
Analisar: níveis de fadiga, força de preensão, HRQoL, níveis de actividade física. Será que se alteram em doentes PAF após o transplante de fígado? Dado que os níveis de actividade física se encontram abaixo dos valores mínimos recomendados deveria ser encontrada uma estratégia de aumento do tempo dispendido na actividade física leve a moderada idealmente no PRÉ TRANSPLANTE.
Resumo:
The nearly ubiquitous consumption of cereals all over the world renders them an important position in international nutrition, but concurrently allocates exposure to possible contained contaminants. Mycotoxins are natural food contaminants, difficult to predict, evade, and reduce, so it is important to establish the real contribution of each contaminated food product, with the aim to evaluate mycotoxin exposure. This was the key objective of this survey and analysis for ochratoxin A content on 274 samples of commercialized bread in the Portuguese market, during the winter 2007. Different bread products were analyzed through an HPLC-FD method, including traditional types, novel segments, and different grain based bread products. A wide-ranging low level contamination was observed in all regions and types of bread products analyzed, especially in the Porto and Coimbra regions, and in the maize and whole-grain or fiber-enriched bread. Nevertheless, the exposure through contaminated wheat bread continues to be the most significant, given its high consumption and dominance in relation to the other types of bread.
Resumo:
Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.
Resumo:
OBJECTIVE: To assess the association between health-related behaviors and quality of life among the elderly. METHODS: A population-based cross-sectional study was carried out including 1,958 elderly living in four areas in the state of São Paulo, southeastern Brazil, 2001/2002. Quality of life was assessed using the Medical Outcomes Study SF-36-Item Short Form Health Survey instrument. This instrument's eight subscales and two components were the dependent variables. Independent variables were physical activity, weekly frequency of alcohol consumption and smoking. Multiple linear regression models were used to control for the effect of gender, age, schooling, work, area of residence and number of chronic conditions. RESULTS: Physical activity was positively associated with the eight SF-36 subscales. The stronger associations were found for role-physical (β=11.9), physical functioning (β=11.3) and physical component. Elderly individuals who consumed alcohol at least once a week showed a better quality of life than those did not consume alcohol. Compared to non-smokers, smokers had a poorer quality of life for the mental component (β=-2.4). CONCLUSIONS: The study results showed that physical activity, moderate alcohol consumption and no smoking are positively associated with a better quality of life in the elderly.