977 resultados para Psychology, Applied
Resumo:
PURPOSE. The purpose of this study was to further assess the psychometric qualities of the Mini-Social Phobia Inventory (MS) to screen for social anxiety disorder (SAD). DESIGN AND METHODS. The MS and other self- and clinician-rated scales for anxiety and social anxiety were applied in 2,314 university students and in samples of SAD patients (n = 88) and nonpatients (n = 90). FINDINGS. The MS revealed adequate discriminative validity, internal consistency (alpha = 0.49-0.73), convergent validity with the Social Phobia Inventory, Brief Social Phobia Scale, and Self-Statements During Public Speaking Scale and convergent and divergent validity with the Beck Anxiety Inventory. PRACTICE IMPLICATIONS. The MS has shown to be a fast and efficient screening instrument for SAD in different cultures and contexts.
Resumo:
Objective. To evaluate the biaxial and short-beam uniaxial strength tests applied to resin composites based upon their Weibull parameters, fractographic features and stress distribution. Methods. Disk- (15 mm x 1 mm) and beam-shaped specimens (10 mm x 2 mm x 1 mm) of three commercial composites (Concept/Vigodent, CA; Heliomolar/Ivoclar-Vivadent, HE; Z250/3M ESPE, FZ) were prepared. After 48h dry storage at 37 degrees C, disks and beams were submitted to piston-on-three-balls (BI) and three-point bending (UNI) tests, respectively. Data were analyzed by Weibull statistics. Fractured surfaces were observed under stereomicroscope and scanning electron microscope. Maximum principal stress (sigma(1)) distribution was determined by finite element analysis (FEA). Maximum sigma(1-BI) and sigma(1-UNI) were compared to FZ strengths calculated by applying the average failure loads to the analytical equations (sigma(a-BI) and sigma(a-UNI)). Results. For BI, characteristic strengths were: 169.9a (FZ), 122.4b (CA) and 104.8c (HE), and for UNI were: 160.3a (FZ), 98.2b (CA) and 91.6b (HE). Weibull moduli ( m) were similar within the same test. CA and HE presented statistically higher m for BI. Surface pores ( BI) and edge flaws ( UNI) were the most frequent fracture origins. sigma(1-BI) was 14% lower than sigma(a-BI.) sigma(1-UNI) was 43% higher than sigma(a-UNI). Significance. Compared to the short-beam uniaxial test, the biaxial test detected more differences among composites and displayed less data scattering for two of the tested materials. Also, biaxial strength was closer to the material`s strength estimated by FEA. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: Verify the influence of radiant exposure (H) on composite degree of conversion (DC) and mechanical properties. Methods: Composite was photoactivated with 3, 6, 12, 24, or 48 J/cm(2). Properties were measured after 48-h dry storage at room temperature. DC was determined on the flat surfaces of 6 mm x 2 mm disk-shaped specimens using FTIR. Flexural strength (FS) and modulus (FM) were accessed by three-point bending. Knoop microhardness number (KHN) was measured on fragments of FS specimens. Data were analyzed by one-way ANOVA/Tukey test, Student`s t-test, and regression analysis. Results: DC/top between 6 and 12 J/cm(2) and between 24 and 48 J/cm(2) were not statistically different. No differences between DC/top and bottom were detected. DC/bottom, FM, and KHN/top showed significant differences among all H levels. FS did not vary between 12 and 24 J/cm(2) and between 24 and 48 J/cm(2). KHN/bottom at 3 and 6 J/cm(2) was similar. KHN between top and bottom was different up to 12 J/cm(2). Regression analyses having H as independent variable showed a plateau region above 24 J/cm(2). KHN increased exponentially (top) or linearly (bottom) with DC. FS and FM increased almost linearly with DC/bottom up to 55% conversion. Conclusions: DC and mechanical properties increased with radiant exposure. Variables leveled off at high H levels. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Objectives: This study tested the following null hypotheses: (1) there is no difference in resin-dentine bond strength when an experimental glutaraldehyde primer solution is added prior to bonding procedures and (2) there is no difference in resin-dentine bond strength when experimental glutaraldehyde/adhesive system is applied under dry or wet demineralized dentine conditions. Methods: Extracted human maxillary third molars were selected. Flat, mid-coronal dentine was exposed for bonding and four groups were formed. Two groups were designated for the dry and two for the wet dentine technique: DRY: (1) Group GD: acid etching + glutaraldehyde primer (primer A) + HEMA/ethanol primer (primer B)-under dried dentine + unfilled resin; (2) Group D: the same as GD, except for primer A application; WET: (3) Group GW: the same as GD, but primer B was applied under wet dentine condition; (4) Group W: the same as GW, except for primer A application. The bonding resin was light-cured and a resin core was built up on the adhesive layer. Teeth were then prepared for microtensile bond testing to evaluate bond strength. The data obtained were submitted to ANOVA and Tukey`s test (alpha = 0.05). Results: Glutaraldehyde primer application significantly improved resin-dentine bond strength. No significant difference was observed when the same experimental adhesive system was applied under either dry or wet dentine conditions. These results allow the first null hypothesis to be rejected and the second to be accepted. Conclusion: Glutaraldehyde may affect demineralized dentine properties leading to improved resin bonding to wet and dry substrates. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
This special issue presents an excellent opportunity to study applied epistemology in public policy. This is an important task because the arena of public policy is the social domain in which macro conditions for ‘knowledge work’ and ‘knowledge industries’ are defined and created. We argue that knowledge-related public policy has become overly concerned with creating the politico-economic parameters for the commodification of knowledge. Our policy scope is broader than that of Fuller (1988), who emphasizes the need for a social epistemology of science policy. We extend our focus to a range of policy documents that include communications, science, education and innovation policy (collectively called knowledge-related public policy in acknowledgement of the fact that there is no defined policy silo called ‘knowledge policy’), all of which are central to policy concerned with the ‘knowledge economy’ (Rooney and Mandeville, 1998). However, what we will show here is that, as Fuller (1995) argues, ‘knowledge societies’ are not industrial societies permeated by knowledge, but that knowledge societies are permeated by industrial values. Our analysis is informed by an autopoietic perspective. Methodologically, we approach it from a sociolinguistic position that acknowledges the centrality of language to human societies (Graham, 2000). Here, what we call ‘knowledge’ is posited as a social and cognitive relationship between persons operating on and within multiple social and non-social (or, crudely, ‘physical’) environments. Moreover, knowing, we argue, is a sociolinguistically constituted process. Further, we emphasize that the evaluative dimension of language is most salient for analysing contemporary policy discourses about the commercialization of epistemology (Graham, in press). Finally, we provide a discourse analysis of a sample of exemplary texts drawn from a 1.3 million-word corpus of knowledge-related public policy documents that we compiled from local, state, national and supranational legislatures throughout the industrialized world. Our analysis exemplifies a propensity in policy for resorting to technocratic, instrumentalist and anti-intellectual views of knowledge in policy. We argue that what underpins these patterns is a commodity-based conceptualization of knowledge, which is underpinned by an axiology of narrowly economic imperatives at odds with the very nature of knowledge. The commodity view of knowledge, therefore, is flawed in its ignorance of the social systemic properties of ��knowing’.