1000 resultados para Custo Histórico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regulatory pressure is increasingly focusing on the use and disposal of substances hazardous to human health and environment. In the last years efforts have also been made to introduce green chemistry concepts in undergraduate courses. In this paper we present an experiment on the oxidation reaction of borneol to camphor with bleach in acetone. This experiment is important to show undergraduate students that a cheap and non hazardous commercial product can be a useful oxidation agent of alcohols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional sample holder cells used to the electric characterization of ceramics at high temperature consists of an alumina tube and platinum wires and plates using a complex design. The high cost materials used in the conventional sampler holder cell were replaced by stainless steel and conventional ceramics. The sample holder was validated by characterizing yttria-stabilized-zirconia in a temperature range of 25 to 700 ºC. The results do not present variations, discontinuity or unusual noise in the electric signals. Several samples were characterized without maintenance, which demonstrates that the sample holder is electric and mechanic adequate to be used to electrical characterization of ceramics up to 700 ºC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present manuscript shows the synthesis of nickel hydroxide supported in carbon (Ni(OH)2/C) as a alternative material for catalytic alcohol oxidation in alkaline medium. The Ni(OH)2/C was synthesized in different percentage using a sonic bath. No current densities variation during successive cyclic voltammetry experiments was observed. The Ni(OH)2/C electrodes exhibit a potent and persistent electrocatalytic activity towards the oxidation of different alcohols. In addition, alcohols electooxidation occurs in less positive potential compared with noble metal catalyst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presently glycerol is considered a co-product of biodiesel industry. As the biodiesel production is exponentially increasing, glycerol generated from the transesterification of vegetable oils and fats is also being produced on a large scale, and turned out to be essential seeking for novel alternatives to the consumption of the extra volume, in crude and/or as derivatives high added value. This review mainly deals with chemical and enzymatic transformations of glycerol to obtain chiral building blocks for synthesis of pharmaceuticals and natural products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared spectroscopy is a versatile technique used for qualitative and quantitative determination of all types of molecular species. As far as analysis of confined or flowing gases is concerned, different types of cell can be found in the market, but they are often very expensive. This study describes the construction of a very efficient gas cell with good reproducibility for qualitative infrared analysis of confined or flowing gases, using easily available and low-cost materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a historical of the Biosilicate®, a bioactive glass-ceramic developed at the Vitreous Materials Laboratory of the Federal University of São Carlos, Brazil. After decades of study accomplished with bioactive glasses and glass-ceramics, Biosilicate® results from a natural evolution and has similar bioactivity index, but far superior mechanical properties than of all bioactive glasses. Biosilicate® is almost fully crystalline and also exhibits much higher bioactivity than all the currently commercially available bioactive glass-ceramics. Due to its special characteristics, Biosilicate® has been successfully tested for several medical and dental applications as we thoroughly discuss in this review paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The construction of a low cost mini sensor containing a bismuth-film electrode (BiFE), as work electrode, a silver electrode as pseudo reference electrode, and copper as counter electrode is proposed. The application of this mini sensor using a low cost electrochemical cell for in loco voltammetric determinations of inorganic and organic analytes is also described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical agents are substances used for their toxic effects on humans, animals and plants. The main objective of chemical defense is to develop systems that reduce these effects while minimizing impact on the operational capacity of military troops. In this work, a report on the development of chemical warfare agents since the First World War and their classification is presented. Special attention is given to neurotoxic agents, the most lethal group of chemical agents known to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extraction/concentration is a crucial step for the analysis of organic compounds at trace level concentrations and dispersed in complex matrices. Solid-phase extraction (SPE) is one of the techniques used for this purpose. In this work, a low cost apparatus for SPE was developed that uses nitrogen under positive pressure and ensures the maintenance of the sample flow, while also allows the simultaneous extraction of different samples without cross-contamination and sample contact with plastic materials. For the system set up, easily accessible materials were used such as hypodermic needles, stainless steel tubes, rubber stoppers, and 3-way valves from serum delivery apparatus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultraviolet radiation corresponds to a fraction of electromagnetic radiation, covering wavelengths between 1 and 400 nm. Methods based on UV irradiation have become popular because it is possible to treat samples simply by applying energy, avoiding procedures that require the use of toxic substances, thus contributing to the development of Green Chemistry. This study aimed to assess the main applications of UV radiation reported in the literature and thoroughly described the construction of an alternative and low-cost photochemical reactor to be used for the pretreatment of samples in the laboratory. The use of this new photochemical reactor in the clean-up of milk samples for spectrofluorimetric measurements was also reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution introduces a brief discussion about the properties and applications of the rare earth elements, with a focus on their current status in Brazil. The general chemical properties, main applications and historical background of the chemistry of these elements are presented, and special attention is devoted to the development of the exploitation and both academic and industrial activities involving rare earths in Brazil. A discussion of the current world scenario ensues and some perspectives regarding the prospection, market and government policy concerning the rare earth elements in Brazil are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a simple and inexpensive flow injection analysis system in which gravity force provides fluid propulsion while needles for insulin administration or metallic wires act as electrodes for amperometric detection. The proposed system was able to demonstrate the influence of several operational parameters on the transient signals. Moreover, this system was successfully used to evaluate both the stoichiometry of Cu2+-EDTA complex and the effect of pH on the kinetics of the reaction between ferricyanide and ascorbic acid. Therefore, the proposed system can be regarded as an efficient and accessible didactic tool for the teaching of FIA principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we describe the development of low-cost teaching experiments of electrogravimetry for undergraduate students using principles of green chemistry. Copper was electrochemically deposited on brass under an electrical current density of 50 mA cm−2 from acidic solutions containing nitrate anions. Color changes at the brass electrode and of the solution were observed, indicating that the reduction of copper ions had occurred. The deposition efficiency values were between 92.8% and 93.8%, and the electrochemical efficiency values were between 85.6% and 86.5%. There was no significant contribution from parallel reactions. These experimental conditions facilitated the didactic exploration of gravimetric and electrochemical concepts. Following the principles of green chemistry, the experiments produced no toxic substances, all the materials could be recycled, and the energy consumption was the lowest. For this reason, this experiment was considered to be very interesting for didactical purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste artigo descreve-se a construção de um calorímetro simples, utilizando materiais de fácil aquisição, para a determinação de entalpia de neutralização (pressão constante) de reações ácido-base. Foram utilizadas para o desenvolvimento do experimento soluções de ácidos e bases fortes e fracos, além de termômetro e recipiente de poliestireno expandido (isopor) para a medida e manutenção da temperatura, respectivamente. Com este experimento, foi então possível determinar a entalpia de neutralização (ΔH) de algumas reações de neutralização e compará-las com o valor mais aceito de - 55,84 kJ mol -1, a 25 ºC [1].