913 resultados para Alpine Fault
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The upper portion of the Rio Guaratuba, located in the Serra do Mar coastal range of Southeastern Brazil, shows biological and geological evidences of being captured and diverted away from its original course in the direction of the Parana River Basin to become a coastal river due to the Quaternary activity of NW-trending faults. Despite draining directly to the Atlantic Ocean, the upper portion of the Guaratuba still maintains an ichthyofauna that is typical of the adjoining Parana River Basin rather than the characteristic fish fauna of the Brazilian coastal drainages. The fish fauna of the upper Guaratuba is an evident testimony of the tectonic process that allowed the faunal interchange between the upland basins and the coastal drainages that probably has been taking place in Southeastern Brazil throughout the long geological history of the passive Brazilian continental margin.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The neutral wire in most existing power flow and fault analysis software is usually merged into phase wires using Kron's reduction method. In some applications, such as fault analysis, fault location, power quality studies, safety analysis, loss analysis etc., knowledge of the neutral wire and ground currents and voltages could be of particular interest. A general short-circuit analysis algorithm for three-phase four-wire distribution networks, based on the hybrid compensation method, is presented. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. A generalised fault analysis method is applied to the distribution network for conditions with and without embedded generation. Results obtained from several case studies on medium- and low-voltage test networks with unbalanced loads, for isolated and multi-grounded neutral scenarios, are presented and discussed. Simulation results show the effects of neutrals and system grounding on the operation of the distribution feeders.
Resumo:
In this article some considerations obtained during the utilization of rotor response analysis techniques in hydraulic powerplants are discussed. An applied research work was carried out in two hydraulic turbines analysing the rotor response both theoretically and experimentally. A developed mathematical model was used to simulate the rotordynamic behaviour of Francis and Kaplan turbines. The main dynamical effects that appear during the operation of the machines are discussed too. A series of measurements were carried out in the turbines using impact hammers to determine the modal behaviour of the units. The tests were carried out with the machine still and in operation. Some results and the comparison with the theory is presented in this article. The improved theoretical model was used for a sensitivity analysis of the different bearings to the main excitations that fake place during the machine operation. From this analysis, the best measuring points for condition monitoring were determined.
Resumo:
An apatite fission track study of crystalline rocks underlying sedimentary basins in northeastern Brazil indicate that crustal blocks that occur on opposite sides of a geological fault experienced different thermal histories. Samples collected on the West block yielded corrected fission-track ages from 140 to 375 Ma, whereas samples collected on the East block yielded ages between 90 and 125 Ma. The thermal models suggest that each block experienced two cooling events separated by a heating event at different times. We concluded that the West block moved downward relative to the East block ca. 140 Ma ago, when sediments eroded from the East side were deposited on the West side. This process represents the early stage of sedimentary basin formation and the opening of the South Atlantic Ocean in the region. Downward and upward movements related to heating and cooling events of these crustal blocks at different periods until recent times are proposed. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The Precambrian crystalline basement of southeast Brazil is affected by many Phanerozoic reactivations of shear zones that developed during the end of the Neoproterozoic in the Brasiliano orogeny. These reactivations with specific tectonic events, a multidisciplinary study was done, involving geology, paleostress, and structural analysis of faults, associated with apatite fission track methods along the northeastern border of the Parana basin in southeast Brazil.The results show that the study area consists of three main tectonic domains, which record different episodes of uplift and reactivation of faults. These faults were brittle in character and resulted in multiple generations of fault products as pseudotachylytes and ultracataclasites, foliated cataclasites and fault gouges.Based on geological evidence and fission track data, an uplift of basement rocks and related tectonic subsidence with consequent deposition in the Parana basin were modeled.The reactivations of the basement record successive uplift events during the Phanerozoic dated via corrected fission track ages, at 387 +/- 50 Ma (Ordovician); 193 +/- 19 Ma (Triassic); 142 +/- 18 Ma (Jurassic), 126 +/- 11 Ma (Early Cretaceous); 89 +/- 10 Ma (Late Cretaceous) and 69 +/- 10 Ma (Late Cretaceous). These results indicate differential uplift of tectonic domains of basement units, probably related to Parana basin subsidence. Six major sedimentary units (supersequences) that have been deposited with their bounding unconformities, seem to have a close relationship with the orogenic events during the evolution of southwestern Gondwana. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
A single-phase superconducting fault current limiter (SFCL) using a 0.9 m length of YBCO coated conductor (CC) tape was tested in 220 V-60 Hz line for fault current up to 1 kA, operating in 77 K. In this work are presented the IN experimental curves measured under DC and AC currents for the electrical characterization of the CC tape in order to design a low voltage current limiter. The experimental setup is described and the test results are presented for a unit conducting a steady nominal AC current of 50 A and also during the fault time (I to 5 cycles.) the performance of the CC-based SFCL providing the limiting resistance developed in the whole tape length after few milliseconds of the beginning of the fault was analyzed.
Resumo:
Eight non-lactating Alpine goats, averaging 57kg, were paired according to weight and assigned randomly to 2 groups of 4 animals, control (CG) and treatment (TG) with feed and water ad libitum. An adjustment period of 7 days with all animals at thermoneutral conditions was followed by a 28-day period when TG was exposed to air temperatures averaging 35.0 degrees C, from 0800 to 1700h, including simulated solar radiation, and thermoneutral conditions from 2700 to 0800h. CG remained under thermoneutral conditions. Respiratory frequency was greater, tidal volume lower, and respiratory minute volume greater for TG than CG (176 vs 30 breaths/min, P<.001, 105 vs 293ml, P<.01; 18.4 vs 9.21, P<.05). Respiratory evaporation and sweating rate as well as rectal and skin temperatures were greater for TG than CG (14.59 vs 6.32 kcal h(-1), P<.01; 43.97 vs.00 g m(-2) h(-1), P<.001; 40.0 vs 38.9 degrees C, P<.001; 39.3 vs 35.8 degrees C, P<.01). There was no difference between groups for hematocrit and feed intake, but water consumption was greater for stressed goats than control ones (28.3 vs 29.7%; 1.44 vs 1.49 kg/day; 3.07 vs 1.26 I/day, P<.05), Final body weights of both groups were similar to initial ones. It was concluded that non-lactating goats tolerated well a 35 degrees C day temperature which is 5 degrees C above the upper critical temperature, with a black-globe temperature of 39.1 degrees C and a Botsball temperature of 28.3 degrees C, though a certain degree of hyperthermia may occur, as long as thermoneutral conditions have prevailed during the night.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.
Resumo:
A new genus and species of cricket, Anomaloterga mantiqueirae, here described, is the first representative of Strogulomorphini to be reported from Brazil. The specimens were collected at night from the lower portions of live tree trunks in a summit forest located on the Mantiqueira Fault Escarpment, State of São Paulo.