Fault current test of a bifilar Bi-2212 bulk coil


Autoria(s): Baldan, Carlos Alberto; Shigue, Carlos Y.; Ruppert Filho, Ernesto
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/06/2008

Resumo

A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.

Formato

664-667

Identificador

http://dx.doi.org/10.1109/TASC.2008.920595

IEEE Transactions on Applied Superconductivity. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 18, n. 2, p. 664-667, 2008.

1051-8223

http://hdl.handle.net/11449/41632

10.1109/TASC.2008.920595

WOS:000256625700139

Idioma(s)

eng

Publicador

Institute of Electrical and Electronics Engineers (IEEE)

Relação

IEEE Transactions on Applied Superconductivity

Direitos

closedAccess

Palavras-Chave #Bi-2212 bulk coil #HTS bifilar coil #HTS coils #superconducting fault current limiter
Tipo

info:eu-repo/semantics/article