884 resultados para in situ technique in electrochemistry


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study reports the production of the rabbit anti-Leishmania (L.) chagasi hyperimmune serum, the standardization of the immunohistochemistry (IHC) technique and the evaluation of its employment in cutaneous leishmaniasis (CL) lesions diagnosed by Leishmania sp. culture isolation. Thirty fragments of active CL lesions were examined as well as 10 fragments of cutaneous mycosis lesions as control group. IHC proved more sensitive in detecting amastigotes than conventional hematoxylin-eosin (HE) stained slides: the former was positive in 24 (80%) biopsies whereas the latter, in 16 (53%) (p = 0.028). The reaction stained different fungus species causing cutaneous mycosis. Besides, positive reaction was noticed in mononuclear and endothelial cells. Nevertheless, this finding was present in the control group biopsies. It is concluded that IHC showed good sensitivity in detecting amastigotes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: In situ breakage of Implanon® is a rare occurrence with unknown clinical significance. Authors report two different cases of broken Implanon® of women attended at our Family Planning Clinic. DISCUSSION: In situ implants may spontaneously and asymptomatically break, although some uncertainty relies on whether that situation has a real impact on the contraceptive effectiveness or on bleeding patterns. Even more, it can be argued if, as a result of an occurrence of that nature, the implant shall or shall not be removed before the envisaged 3-year period of effectiveness. CONCLUSION: Currently, the clinical significance of implant breakage remains unknown. The decision to remove a broken or bent implant should be based on clinical judgements considering patients' wishes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A conjuntura económica da construção não se encontra numa fase de prosperidade, existindo a necessidade de criar soluções construtivas que permitam a redução de custos dos materiais a nível de obra. As lajes de betão armado, devido à sua grande área de implantação, possuem uma parcela importante no orçamento final de qualquer obra de edifícios correntes. Sabendo das possibilidades de aligeiramento de lajes, torna-se necessária a realização de um estudo pormenorizado e comparativo entre soluções de aligeiramento. O desenvolvimento deste relatório reflete todo o trabalho efetuado durante a realização de um estágio curricular desenvolvido na empresa FercaNorte – Estruturas, Lajes e Cofragens, Lda. e foca-se num dimensionamento e estudo comparativo de soluções de lajes fungiformes aligeiradas, aplicadas a dois casos de estudo e também num dimensionamento e estudo comparativo de soluções de lajes aligeiradas unidirecionais mas apenas aplicadas a um caso de estudo. No primeiro caso de estudo, laje fungiforme com um vão de 6 metros nas duas direções, são dimensionadas e comparadas quatro soluções: laje fungiforme maciça; laje fungiforme aligeirada com blocos elipsoides perdidos dispostos de forma ortogonal e envolvidos totalmente por betão; laje fungiforme aligeirada com blocos elipsoides perdidos dispostos em formato de favo de mel e envolvidos totalmente por betão; e laje fungiforme nervurada com moldes recuperáveis. No segundo caso de estudo, laje fungiforme com um vão de 7,04 metros nas duas direções, são dimensionadas e comparadas cinco soluções: laje fungiforme maciça, laje fungiforme aligeirada com blocos cúbicos perdidos dispostos de forma ortogonal e envolvidos totalmente por betão; laje fungiforme aligeirada, com blocos elipsoides perdidos dispostos de forma ortogonal e envolvidos totalmente por betão; laje fungiforme aligeirada com blocos elipsoides perdidos dispostos em formato de favo de mel e envolvidos totalmente por betão; e laje fungiforme nervurada com moldes recuperáveis. No terceiro caso de estudo, laje unidirecional com um vão de 8 metros apoiada em vigas com vão de 5 metros, são dimensionadas e comparadas três soluções: laje maciça; laje aligeirada com perfis tubulares com secção transversal reta oval; e laje nervurada com moldes recuperáveis. No final é apresentada uma estimativa orçamental para cada solução analisada nos três casos de estudo abordados.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO:As terapias biológicas revolucionaram o tratamento das doenças autoimunes nos últimos anos. Tipicamente têm como alvos mediadores importantes no mecanismo das doenças. Os antagonistas do fator de necrose tumoral-α (TNF-α) são um grupo de agentes biológicos muito prescrito, pois estão indicados no tratamento de doenças imuno-mediadas comuns, tais como artrite reumatoide, artrite idiopática juvenil, artrite psoriática, espondilite anquilosante, doença de Crohn e colite ulcerosa. Com o uso frequente de inibidores do TNF-α, tem-se tornado evidente que estes agentes têm um potencial imunogénico importante, que pode comprometer o prognóstico a longo prazo dos doentes cronicamente tratados. A produção de anticorpos anti-fármaco parece causar falência terapêutica secundária em muitos doentes. Um dos efeitos dos anticorpos anti-fármaco é o aumento da eliminação do fármaco. A eliminação do fármaco, por sua vez, varia entre indivíduos, refletindo diferentes perfis farmacocinéticos. A determinação dos níveis séricos mínimos do agente anti-TNF-α é assim muito informativa e pode auxiliar nas decisões terapêuticas. Contudo, os testes imunológicos para determinar as concentrações séricas do fármaco não estão facilmente disponíveis na prática clínica. De forma a investigar uma nova técnica potencialmente fidedigna e prática para a deteção e quantificação dos agentes biológicos anti-TNF-α, foi testada a técnica por HTRF (homogeneous time-resolved fluorescence resonance energy transfer) para a determinação de concentrações séricas de infliximab. Apesar de apresentar algumas limitações relacionadas com as condições de leitura da fluorescência, esta técnica provou obter resultados próximos das concentrações obtidas por ELISA (enzyme-linked immunosorbent assay) bridging. Adicionalmente, tem a vantagem de ser de execução muito mais fácil e rápida. Deste modo, a técnica por HTRF poderá ser otimizada e tornar-se uma valiosa ferramenta laboratorial para orientar as decisões terapêuticas em doentes autoimunes com falência da terapêutica anti-TNF-α.--------- ABSTRACT: Biologic therapies revolutionized the treatment of autoimmune diseases in the last years. Typically, they target important disease mediators. Tumor necrosis factor-alpha (TNF-α) antagonists constitute a very prescribed group of biologic agents as they are indicated for the treatment of common immune-mediated diseases, such as rheumatoid arthritis, juvenile idiopathic arthritis, psoriatic arthritis, ankylosing spondylitis, Crohn’s disease and ulcerative colitis. With the increasing use of TNF-α inhibitors it has been noticed that they have an important immunogenic potential that can compromise long-term outcomes in chronically treated patients. The production of anti-drug antibodies seems to cause secondary therapeutic failure in many patients. One of the effects of anti-drug antibodies is the enhancement of drug clearance. Drug clearance, in turn, varies among individuals, reflecting different pharmacokinetic profiles. Determination of serum anti-TNF-α drug trough levels is though very informative and could support treatment decisions. However, immunologic assays to determine drug serum concentrations are not readily available in clinical practice. In order to investigate a potentially reliable and practical new technique for detection and quantification of anti-TNF-α biologic agents, homogeneous time-resolved fluorescence resonance energy transfer (HTRF) technique was tested for determination of serum infliximab concentrations. Although presenting some limitations related with fluorescence reading conditions, this technique proved to give results close to the concentrations obtained by the widely used bridging enzyme-linked immunosorbent assay (ELISA). In addition, it has the advantage of being much easier and faster to perform. Thus, HTRF technique can be optimized and become a valuable laboratorial tool to guide treatment decisions in autoimmune patients with anti-TNF-α therapy failure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The unlabelled antibody peroxidase-antiperoxidase method was used to study the immunocytochemical properties of Leishmania and Trypanosoma cruzi amastigotes in situ after tissues had been submitted to different fixation procedures. Antisera were obtained from rabbits chronically infected with different strains of T. cruzi or immunized with L. mexicana amazonensis and L. braziliensis guyanensis, and were applied on 5 µm thick sections. T. cruzi antigens were well stained by the three anti-T. cruzi sera and the two anti-heis.hmama.sera at optimum dilution between 1:1,000 and 1:2,000, regardless the parasite strain. Differently, the leishmanial antigens were revealed by Leishmania sera only at low dilutions (between 1:60 -1:160), whereas the anti-T. cruzi sera, at these low dilutions, gave rather weak stainings. Although there is no clear explanation for this immunocytochemical "reverse-monodirectional" cross-reactivity between Leishmania and T. cruzi, the present results show that polyclonal antibodies agains Leishmania species, when used for immunocytochemical detection of these parasites in situ, react more strongly with T. cruzi amastigotes than with the homologous amastigotes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Civil – Perfil de Construção

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Resumo: Objetivou-se avaliar a degradação in situ da Jurema preta. Foram estimados os valores da degradação potencial e efetiva da matéria seca, proteína bruta e fibra em detergente neutro. A jurema preta apresenta bom potencial de degradação para matéria seca e fibra em detergente neutro, já para a proteína bruta, parece haver necessidade de ação enzimática pós rúmen para que seja melhor aproveitada. [In situ degradability of jurema preta (Mimosa tenuiflora) in thinned and enriched caatinga rangelands]. Abstract: We aimed with this manuscript to present the evaluation of in situ degradability of Jurema preta in thinned and enriched caatinga. Were estimated the potential and effective degradation of dry matter, crude protein and neutral detergent fiber. The jurema preta shrubs have good potential to dry matter and neutral detergent fiber degradation, but to crude protein, to maximize their harnessing the post rumen digestion is needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A utilização dos carvões activados na remoção compostos poluentes dos efluentes urbanos tem demonstrado ser um processo cada vez mais económico e eficaz, sendo por isso muito utilizado no sector de tratamento e purificação de águas de abastecimento. O principal objectivo desta dissertação foi aplicar espectroscopia UV-Vis in situ no processo de adsorção em fase líquida de PPCP’s, nomeadamente cafeína e paracetamol. Nesta nova abordagem de medição e procedimento experimental, tiveram de se ter em conta vários factores e estudar o seu efeito durante o processo de adsorção. Um destes factores é a presença do carvão durante a medição da absorvância em espectroscopia. Deste modo, foram realizadas medições ao longo do tempo em soluções de carvão activado para determinar qual a sua interferência na medição e os motivos de tal comportamento. Verificou-se também que a forma, a quantidade e a agitação do carvão também influenciam os resultados de espectroscopia. Aplicando este novo método de medição, foi necessário adaptar a lei de Lambert-Beer para calcular os valores de concentração das espécies em solução, eliminando o erro na medição, provocado pela presença do carvão. Deste modo, o método de decomposição espectral foi aplicado e verificou-se que apenas as concentrações de carvão calculadas não correspondem aos valores reais em solução, apenas a sua variação demostra a evolução da interferência do adsorvente na medição dos valores de absorvância. No estudo cinético de adsorção dos solutos foi usado um carvão comercial tanto em pó como em formato granular. Durante o processo de adsorção em carvão granular verificou-se que a velocidade de adsorção foi menor, provavelmente devido à maior dificuldade de acesso aos poros, provocada pela complexidade da estrutura. Contudo, registou-se sempre uma remoção completa do soluto neste carvão, uma vez que a quantidade mínima possível nestes ensaios de carvão NOG é de 2,5mg, sendo uma quantidade relativamente superior à necessária para remover o soluto completamente da solução. Num pequeno estudo de adsorção de cafeína em carvões de diferentes origens confirmou-se que a eficiência de remoção do soluto é proporcional ao volume total de poros e deduz-se que a sua velocidade de adsorção está relacionada com a presença de mesoporosidade. Comparando a eficiência de remoção e a velocidade de adsorção dos dois solutos pelo mesmo carvão, observou-se que a adsorção da cafeína é mais rápida. Apesar dos valores de solubilidade e de volume molecular não justificarem de imediato este resultado, a cafeína tem maior afinidade com o carvão comercial, sugerindo a existência de propriedades químicas e texturais do carvão que levam a estes resultados. Por último, efectuou-se um estudo de adsorção de misturas para verificar a hipótese de adsorção competitiva entre os solutos. Após a realização dos ensaios verificou-se que não existe competição significativa entre a cafeína e o paracetamol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação para a Ciência e a Tecnologia (FCT) - PhD grant (SFRH/BD/62568/2009)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: Studies strongly indicate Dientamoeba fragilis as one of the causes of diarrhea in human immunodeficiency virus (HIV) patients. METHODS: The objective of the present study was to evaluate the prevalence of D. fragilis associated with the causes of diarrhea in 82 HIV/ AIDS patients hospitalized at the Instituto de Infectologia Emílio Ribas from September 2006 to November 2008. RESULTS: In total, 105 samples were collected from 82 patients. Unprotected sex was the most frequent cause of HIV infection (46.3%), followed by the use of injectable or non-injectable drugs (14.6%). Patients presented with viral loads of 49-750,000 copies/ mL (average: 73,849 ± 124,850 copies/mL) and CD4 counts ranging of 2-1,306 cells/mm³ (average: 159 ± 250 cells/mm³). On an average, the odds of obtaining a positive result by using the other techniques (Hoffman, Pons and Janer or Lutz; Ritchie) were 2.7 times higher than the chance of obtaining a positive result by using the simplified iron hematoxylin method. Significant differences were found between the methods (p = 0.003). CONCLUSIONS: The other techniques can detect a significantly greater amount of parasites than the simplified iron hematoxylin method, especially with respect to Isospora belli, Cryptosporidium sp., Schistosoma mansoni, and Strongyloides stercoralis, which were not detected using hematoxylin. Endolimax nana and D. fragilis were detected more frequently on using hematoxylin, and the only parasite not found by the other methods was D. fragilis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction This study evaluated the performance of an in-house nested-PCR system for the detection of the Mycobacterium tuberculosis complex in pleural fluid, blood and urine samples from pleural effusion tuberculosis patients by health services physicians in Pernambuco, Brazil. Methods A prospective double-blind study with 37 hospitalized patients of both sexes, aged over 15, was used to investigate the diagnosis of pleural effusion. The criteria used to define the cases included the demonstration of bacillus in biological samples by smear or culture or by a granulomatous finding in the histopathological examination, associated with an evident response to specific treatments to each clinical situation. Pleural fluid, blood and urine samples were collected and subjected to routine tests and the nested PCR technique to assess for M. tuberculosis amplification. Results In total, 37 pleural effusion patients took part in the study, of whom 19 (51.3%) had tubercular etiologies and 18 (48.7%) had etiologies from other causes. When the pleural fluid, blood and/or urine sample in-house nested-PCR sensitivities were evaluated simultaneously, the results were positive regardless of the biological specimen (the sensitivity was 84.2%); however, when the blood and/or urine samples were analyzed together, the sensitivity was 72.2%. When the pleural fluid samples were evaluated alone, the sensitivity was only 33.3%. Conclusions The performance of the diagnostic pleural tuberculosis nested-PCR was directly related to the diversity of the samples collected from the same patient. Additionally, this study may identify a need to prioritize non-invasive blood and urine collection for this diagnosis.