970 resultados para improving competitive ability
Resumo:
Introduction: The aim of this study was to evaluate the biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin. Methods: One hundred twenty bovine dentin specimens were infected intraorally by using a removable orthodontic device. Thirty samples were used for each irrigant solution: 2% chlorhexidine and 1%, 2.5%, and 5.25% sodium hypochlorite (NaOCl). The solutions were used for 5, 15, and 30 minutes and at 2 experimental volumes, 500 mu L and 1 mL. The samples were stained by using acridine orange dye before and after the experiments and evaluated by using a confocal microscope. The percentage of biofilm, isolated cells, and noncolonized dentin was measured by using a grid system. Differences in the reduction or increase of the studied parameters were assessed by using nonparametric methods (P < .05). Results: The higher values of biofilm dissolution and noncolonized dentin were found in the 30-minute NaOCl group and in the 5-minute and 15-minute groups of 5.25% NaOCL. The use of 2% chlorhexidine solution did not improve the biofilm dissolution or increase the cleaning of the dentin in comparison with the NaOCl solutions (P < .05). Conclusions: Two percent chlorhexidine does not dissolve the biofilms. Thirty minutes of NaOCl are necessary to have higher values of biofilm dissolution and to increase the cleaning of the dentin independently of the concentration in comparison with the 5-minute and 15-minute contact times. (J Endod 2011;37:1134-1138)
Resumo:
Objective: To evaluate whether the type of cola drink (regular or diet) could influence the wear of enamel subjected to erosion followed by brushing abrasion, Method and !Materials: Ten volunteers wore intraoral devices that each had eight bovine enamel blocks divided into four groups; ER, erosion with regular cola; EAR, erosion with regular cola plus abrasion; EL, erosion with light cola; and EAL, erosion with light cola plus abrasion, Each day for 1 week, half of each device was immersed in regular cola for 5 minutes, Then, two blocks were brushed using a fluoridated toothpaste and electric toothbrush for 30 seconds four times daily, Immediately after, the other half of the device was subjected to the same procedure using a light cola, The pH, calcium, phosphorus, and fluoride concentrations of the colas were analyzed using standard procedures, Enamel alterations were measured by profilometry. Data were tested using two-way ANOVA and Bonferroni test (P < .05), Results: Regarding chemical characteristics, light cola presented pH 3.0, 13.7 mg Ca/L, 15.5 mg P/L, and 0.31 mg F/L, while regular cola had pH 2.6, 32.1 mg Ca/L, 1:8.1 mg P/L, and 0.26 mg F/L, The light cola promoted less enamel loss (EL, 0.36 pm; EAL, 0.39 pm) than its regular counterpart (ER, 0.72 pm; EAR, 0.95 pm) for both conditions, There was not a significant difference (P > .05) between erosion and erosion plus abrasion for light cola, However, for regular cola, erosion plus abrasion resulted in higher enamel loss than erosion alone,.nclusion: The data suggest that light cola promoted less enamel wear even when erosion was followed by brushing abrasion, (Quintessence Int 2011;42:xxx-xx)()
Resumo:
With the proliferation of relational database programs for PC's and other platforms, many business end-users are creating, maintaining, and querying their own databases. More importantly, business end-users use the output of these queries as the basis for operational, tactical, and strategic decisions. Inaccurate data reduce the expected quality of these decisions. Implementing various input validation controls, including higher levels of normalisation, can reduce the number of data anomalies entering the databases. Even in well-maintained databases, however, data anomalies will still accumulate. To improve the quality of data, databases can be queried periodically to locate and correct anomalies. This paper reports the results of two experiments that investigated the effects of different data structures on business end-users' abilities to detect data anomalies in a relational database. The results demonstrate that both unnormalised and higher levels of normalisation lower the effectiveness and efficiency of queries relative to the first normal form. First normal form databases appear to provide the most effective and efficient data structure for business end-users formulating queries to detect data anomalies.
Resumo:
Evaluate, through computerized tomography, canal transportation and centring ability of RaCe rotary instruments after preparation of mesiobuccal root canals in maxillary molar teeth. Twenty-seven teeth were submitted to three cone beam tomographic analyses, one preoperatively, and two after preparation with file size 35, .02 taper and size 50, .02 taper. Canal transportation and centring ability were measured with reference to the distance between the noninstrumented portion of the root canals and the mesial and distal periphery of the root, compared with images obtained after the preparation with size 35 and 50 instruments. Canal transportation after preparation with the size 35 file was 0.030 +/- 0.253 mm and after the size 50 file was 0.057 +/- 0.317 mm. The centring ratio values after preparation with the size 35 file was 0.42 +/- 0.32 and after the size 50 file was 0.54 +/- 0.29, with no significant statistical difference between the groups. RaCe instruments allowed the preparation of curved root canals with preparation diameters larger than those normally used with minimal canal transportation and adequate centring ability.
Resumo:
Objective. To evaluate the influence of shaft design on the shaping ability of 3 rotary nickel-titanium (NiTi) systems. Study design. Sixty curved mesial canals of mandibular molars were used. Specimens were scanned by spiral tomography before and after canal preparation using ProTaper, ProFile, and ProSystem GT rotary instruments. One-millimeter-thick slices were scanned from the apical end point to the pulp chamber. The cross-sectional images from the slices taken earlier and after canal preparation at the apical, coronal, and midroot levels were compared. Results. The mean working time was 137.22 +/- 5.15 s. Mean transportation, mean centering ratio, and percentage of area increase were 0.022 +/- 0.131 mm, 0.21 +/- 0.11, and 76.90 +/- 42.27%, respectively, with no statistical differences (P > .05). Conclusions. All instruments were able to shape curved mesial canals in mandibular molars to size 30 without significant errors. The differences in shaft designs seemed not to affect their shaping capabilities.
Resumo:
Aim of study: This study sought to determine whether multidisciplinary case conference reviews improved outcomes for nursing home residents, and the effects of this team approach to resident care on carers, including the hands-on carers employed by the nursing home, and health professionals. Method: 245 residents of three Canberra nursing homes were enrolled in this non-randomised controlled trial. The intervention consisted of sessions of three case conference reviews held between 10/4/96 and 4/12/96. These sessions were attended by the General Practitioners (GPs) of the residents discussed, the GP project officer from the ACT Division of General Practice, a clinical pharmacist, senior nursing staff, other health professionals eg physiotherapist, and occasionally the resident concerned or their representative. At each review, a case presentation by the resident's GP was followed by a multidisciplinary discussion of all aspects, medical and non-medical, of the resident's care. The review concluded with a management plan for the resident. In total 75 residents were reviewed. Main outcome measures: Medication use and cost, and mortality. Results: One month after the reviews were completed comparisons between those who were reviewed and those who were not showed non-significant reductions in medication orders, medication cost, and mortality in the reviewed group. Many of the 92 recommendations in the management plans that were carried out benefited the residents (n=37) and/or carers (n=24). The responses of the GPs and the Directors of Nursing to the reviews were overwhelmingly positive. Conclusion: Recommendations arising from multidisciplinary case conferences were carried out to the benefit of patients and carers. Given the support shown by key stakeholders, multidisciplinary conferences should be used more.
Resumo:
A range of topical products are used in veterinary medicine. The efficacy of many of these products has been enhanced by the addition of penetration enhancers. Evolution has led to not only a highly specialized skin in animals and humans, but also one whose anatomical structure and skin permeability differ between the various species. The skin provides an excellent barrier against the ingress of environmental contaminants, toxins, and microorganisms while performing a homeostatic role to permit terrestrial life. Over the past few years, major advances have been made in the field of transdermal drug delivery. An increasing number of drugs are being added to the list of therapeutic agents that can be delivered via the skin to the systemic circulation where clinically effective concentrations are reached. The therapeutic benefits of topically applied veterinary products is achieved in spite of the inherent protective functions of the stratum corneum (SQ, one of which is to exclude foreign substances from entering the body. Much of the recent success in this field is attributable to the rapidly expanding knowledge of the SC barrier structure and function. The bilayer domains of the intercellular lipid matrices within the SC form an excellent penetration barrier, which must be breached if poorly penetrating drugs are to be administered at an appropriate rate. One generalized approach to overcoming the barrier properties of the skin for drugs and biomolecules is the incorporation of suitable vehicles or other chemical compounds into a transdermal delivery system. Indeed, the incorporation of such compounds has become more prevalent and is a growing trend in transdermal drug delivery. Substances that help promote drug diffusion through the SC and epidermis are referred to as penetration enhancers, accelerants, adjuvants, or sorption promoters. It is interesting to note that many pour-on and spot-on formulations used in veterinary medicine contain inert ingredients (e.g., alcohols, amides, ethers, glycols, and hydrocarbon oils) that will act as penetration enhancers. These substances have the potential to reduce the capacity for drug binding and interact with some components of the skin, thereby improving drug transport. However, their inclusion in veterinary products with a high-absorbed dose may result in adverse dermatological reactions (e.g., toxicological irritations) and concerns about tissue residues. These a-re important considerations when formulating a veterinary transdermal product when such compounds ate added, either intentionally or otherwise, for their penetration enhancement ability. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Objectives: To reevaluate the longevity and intraocular safety of recombinant adenovirus (rAd)-mediated gene delivery after subretinal injection, and to prolong transgene expression through the combination of 2 synergistic immunosuppressants. Methods: An rAd vector carrying green fluorescent protein (GFP) gene was delivered subretinally in the rat eye. The GFP expression was monitored in real time by fundus fluorescent photography. Intraocular safety was examined by observation of changes of retinal pigmentation, cell infiltration in virus-contacted area, immunophenotyping for CD4(+) and CD8(+) cytotoxic T lymphocytes, and CD68(+) macrophages, histologic findings, and dark-adapted electroretinography. Two synergistic immunosuppressants, cyclosporine and sirolimus, were used alone or in combination to prolong transgene expression by temporary immunosuppression. Results: The GFP expression peaked on day 4, dramatically decreased on day 10, and was not detectable on day 14. The decreased GFP expression was coincident with cell infiltration in virus-contacted area. Immunostaining showed that the infiltrating cells were CD4(+) and CD8(+) cytotoxic T lymphocytes and CD68(+) macrophages. Clumped retinal pigmentation and decreased b wave of dark-adapted electroretinogram were observed at 3 to 4 weeks after injection. Histologic examination confirmed rAd-induced retinal degeneration. Transient immunosuppression by cyclosporine and sirolimus, either alone or in combination, improved transgene expression, with the combination being the most efficient. The combined immunosuppression attenuated but did not retard the rAd-induced retinal damage. Conclusions: Transgene expression mediated by rAd after subretinal delivery is short-term and toxic to the retina. Combination of cyclosporine and sirolimus may act as an immunosuppressive adjunct to prolong rAd-mediated gene transfer. Clinical Relevance: The intraocular safety of rAd should be carefully considered before clinical trials are performed.
Resumo:
We report a study in which Italian children aged 3 to 5 years were given situations requiring a distinction between lies and honest mistakes. As in previous research, the children displayed an incipient grasp of the lie-mistake distinction with regard to situations involving falsehoods about edibility of a substance that had been contaminated. However, children of all ages often regarded instances of both lies and mistakes as negative rather than restricting their judgements of naughtiness to the lying alone. The results are discussed in terms of the characteristics of Italian language and culture such as the connotations of words used to indicate mistakes'' and references to anger in labelling a variety of emotional events.
Resumo:
Significant pain continues to be reported by many hospitalized patients despite the numerous and varied educational programs developed and implemented to improve pain management. A theoretically based Peer Intervention Program was designed from a predictive model to address nurses' beliefs, attitudes, subjective norms, self-efficacy, perceived control and intentions in the management of pain with p.r.n. (as required) narcotic analgesia. The pilot study of this program utilized a quasi-experimental pre-post test design with a patient intervention, nurse and patient intervention and control conditions consisting of 24, 18 and 19 nurses, respectively. One week after the intervention, significant differences were found between the nurse and patient condition and the two other conditions in beliefs, self-efficacy, perceived control, positive trend in attitudes, subjective norms and intentions. The most positive aspects of the program were supportive interactive discussions with peers and an awareness and understanding of beliefs and attitudes and their roles in behavior.
Resumo:
A major consideration in the performance of mouthguards is their ability to absorb energy and reduce transmitted forces when impacted. This is especially important to participants in contact sports such as hockey or football. The thickness of mouthguard materials is directly related to energy absorption and inversely related to transmitted forces when impacted. However, wearer comfort is also an important factor in their use. Thicker mouthguards are not user-friendly. While thickness of material over incisal edges and cusps of teeth is critical, just how thick should a mouthguard be and especially in these two areas? Transmitted forces through different thicknesses of the most commonly used mouthguard material, ethylene vinyl acetate (EVA) (Shore A Hardness of 80) were compared when impacted with identical forces which were capable of damaging the oro-facial complex. The constant impact force used in the tests was produced by a pendulum and had an energy of 4.4 joules and a velocity of 3 meters per second. Improvements in energy absorption and reductions in transmitted forces were observed with increasing thickness. However, these improvements lessened when the mouthguard material thickness was greater than 4 mm. The results show that the optimal thickness for EVA mouthguard material with a Shore A Hardness of 80 is around 4 mm. Increased thickness, while improving performance marginally, results in less wearer comfort and acceptance.