951 resultados para cylindrical grinding


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Comparisons are made between experimental measurements and numerical simulations of ionizing flows generated in a superorbital facility. Nitrogen, with a freestream velocity of around 10 km/s, was passed over a cylindrical model, and images were recorded using two-wavelength holographic interferometry. The resulting density, electron concentration, and temperature maps were compared with numerical simulations from the Langley Research Center aerothermodynamic upwind relaxation algorithm. The results showed generally good agreement in shock location and density distributions. Some discrepancies were observed for the electron concentration, possibly, because simulations were of a two-dimensional flow, whereas the experiments were likely to have small three-dimensional effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is argued that the common classification of abrasive wear into 'two-body abrasion' and 'three-body abrasion' is seriously flawed. No definitions have been agreed upon for these terms, and indeed there are two quite different interpretations, the implications of which are mutually inconsistent. In the dominant interpretation, the primary thrust of the two-body/three-body concept is to describe whether the abrasive particles are constrained (two-body) or free to roll (three-body). In this view, two-body abrasion is generally much more severe than three-body. The alternative interpretation emphasises the presence (three-body) or absence (two-body) of a rigid counterface backing the abrasive. In this view, three-body abrasion is equated to high-stress (or grinding) abrasion and is generally more severe than two-body (low-stress) abrasion. This paper recommends that the 'two-body/three-body' terminology be abandoned, to be replaced by an alternative classification scheme based directly upon the manifest severity of wear. (C) 1998 Elsevier Science S.A.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The classical model of capillary equilibrium in cylindrical pores is modified here by the introduction of molecular concepts and the solid fluid interaction potential. The new approach accurately predicts capillary coexistence and criticality, with results quantitatively matching those from density functional theory for nitrogen adsorption, while also predicting condensation pressures in agreement with reported experimental findings for MCM-41. The larger critical pore size for nitrogen adsorption in these materials, however, suggests a modification of the potential function parameters, evaluated here from data for hydroxylated silica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The most common types of weirs are the broad-crested weir, the sharp-crested weir, the circular-crested weir, and nowadays, the ogee crest weir, Advantages of the cylindrical weir shape include the stable overflow pattern, the ease to pass floating debris, the simplicity of design compared to ogee crest design, and the associated lower costs. in this study, the writers describe new experiments of circular weir overflows, with eight cylinder sizes, for several weir heights and for five types of inflow conditions: partially developed inflow, fully developed inflow, upstream ramp, upstream undular hydraulic jump, and upstream (breaking) hydraulic jump. Within the range of the experiments, the cylinder size, the weir height DIR and the presence of an upstream ramp had no effect on the discharge coefficient, flow depth at crest, and energy dissipation. But the inflow conditions had substantial effects on the discharge characteristics and flow properties at the crest. Practically, the results indicate that discharge measurements with circular weirs are significantly affected by the upstream flow conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a magnetic resonance imaging equipment, gradient and shim coils are needed to produce a spatially varying magnetic field throughout the sample being imaged. Such coils consist of turns of wire wound on the surface of a cylindrical tube. Shim coils in particular, must sometimes be designed to produce complicated magnetic fields to correct for impurities. Streamline patterns for shim coils are much more complicated than those for gradient coils, In this work we present a detailed analysis of streamline methods and their application to shim coil design, A method is presented for determining the winding patterns to generate these complicated fields. (C) 2002 John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a numerical technique for the design of an RF coil for asymmetric magnetic resonance imaging (MRI) systems. The formulation is based on an inverse approach where the cylindrical surface currents are expressed in terms of a combination of sub-domain basis functions: triangular and pulse functions. With the homogeneous transverse magnetic field specified in a spherical region, a functional method is applied to obtain the unknown current coefficients. The current distribution is then transformed to a conductor pattern by use of a stream function technique. Preliminary MR images acquired using a prototype RF coil are presented and validate the design method. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface characterization of 6H-SiC (0001) substrates in indentation and abrasive machining was carried out to investigate microfracture, residual damage, and surface roughness associated with material removal and surface generation. Brittle versus plastic deformation was studied using Vickers indention and nano-indentation. To characterize the abrasive machining response, the 6H-SiC (0001) substrates were ground using diamond wheels with grit sizes of 25, 15 and 7 mum, and then polished with diamond suspensions of 3 and 0.05 mum. It is found that in indentation, there was a scale effect for brittle versus plastic deformation in 6H-SiC substrates. Also, in grinding, the scales of fracture and surface roughness of the substrates decreased with a decrease in diamond grit size. However, in polishing, a reduction in grit size of diamond suspensions gave no significant improvement in surface roughness. Furthermore, the results showed that fracture-free 6H-SiC (0001) surfaces were generated in polishing with the existence of the residual crystal defects, which were associated with the origin of defects in single crystal growth. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spermatozoa of most crustacean species are nonmotile and are packed into spermatophores. In Decapoda, spermatophores are highly variable in morphology and can be useful in the solving of taxonomic and systematic questions, especially among the Anomura. In this study, the morphology and morphometry of the spermatophores of the western Atlantic hermit crabs Pagurus brevidactylus and P criniticornis are described. The abdomen of fresh male specimens was dissected to expose the reproductive system and to extract the spermatophores, which were analyzed by stereoscopic, light, and scanning electron microscopy. The vas deferens can be divided macroscopically in three regions, all of them containing spermatophores. Tripartite spermatophores are composed of an elongated cylindrical main ampulla, a triangular accessory ampulla, a narrow cylindrical peduncle, and a round pedestal. Dimensions of the spermatophore components are positively correlated to the size of the crab. Morphological patterns observed in this study resemble those of other pagurid hermit crabs investigated to date. The morphological character distribution confirms classifications based on adult morphology and molecular analysis. J. Morphol. 272:1271-1280, 2011. (C) 2011 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports a parametric investigation and development of grinding technologies for micro aspherical mould inserts using parallel grinding method. The parametric investigation revealed that at nanometric scale the undeformed chip thickness has little influence on the surface finish of ground inserts. The grinding trace spacing has a slightly larger influence on the surface finish. A new technique was developed to true and dress the resin bonded micro wheels with mesh size of #3000, which produced a satisfactory wheel form accuracy and relatively high grain packing density. A form error compensation technique was also developed, with which mould inserts of submicron form accuracy were consistently produced. Using the developed technologies, micro aspherical inserts of diameters ranging from 200 mu m to 1000 mu m with surface finish of around 10 nm and form error of similar to 0.2-0.4 mu m were successfully fabricated. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction This is a case report of a 39-year-old patient with a 14-year history of clinically refractory cluster headache (CH), also presenting obstructive sleep apnea (OSA) and complaining of tooth-grinding during sleep. Discussion Treatment of OSA with an intra-oral device allowed an immediate reduction in frequency and intensity of CH events. Furthermore, CH attacks did not occur during the 12-month follow-up period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The kinetics of mechanical alloying have been investigated by examining the effect that ball mass has on the rate at which titanium carbide forms from the elements. By varying the ball density while keeping the ball diameter and the charge ratio constant, the collision energy was independently controlled. Grinding media with a density from 3.8 g cm(-3) (agate) to 16.4 g cm(-3) (tungsten carbide) were used. The reaction rate increases exponentially with ball mass until a critical level is reached, which is determined by the induced temperature rise. Above this level, collisions of higher energy have no advantage. It is also shown that the reaction rate increases exponentially with the rate at which strain accumulates in the reactants. It is suggested that the strain accumulation rate in mechanically induced reactions is analogous to temperature in thermally induced chemical reactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider solutions to the second-harmonic generation equations in two-and three-dimensional dispersive media in the form of solitons localized in space and time. As is known, collapse does not take place in these models, which is why the solitons may be stable. The general solution is obtained in an approximate analytical form by means of a variational approach, which also allows the stability of the solutions to be predicted. Then, we directly simulate the two-dimensional case, taking the initial configuration as suggested by the variational approximation. We thus demonstrate that spatiotemporal solitons indeed exist and are stable. Furthermore, they are not, in the general case, equivalent to the previously known cylindrical spatial solitons. Direct simulations generate solitons with some internal oscillations. However, these oscillations neither grow nor do they exhibit any significant radiative damping. Numerical solutions of the stationary version of the equations produce the same solitons in their unperturbed form, i.e., without internal oscillations. Strictly stable solitons exist only if the system has anomalous dispersion at both the fundamental harmonic and second harmonic (SH), including the case of zero dispersion at SH. Quasistationary solitons, decaying extremely slowly into radiation, are found in the presence of weak normal dispersion at the second-harmonic frequency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new variation of holographic interferometry has been utilized to perform simultaneous two-wavelength measurements, allowing quantitative analysis of the heavy particle and electron densities in a superorbital facility. An air test gas accelerated to 12 km/s was passed over a cylindrical model, simulating reentry conditions encountered by a space vehicle on a superorbital mission. Laser beams with two different wavelengths have been overlapped, passed through the test section, and simultaneously recorded on a single holographic plate. Reconstruction of the hologram generated two separate interferograms at different. angles from which the quantitative measurements were made. With this technique, a peak electron concentration of (5.5 +/- 0.5) x 10(23) m(-3) was found behind a bow shock on a cylinder. (C) 1997 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transanal access is one of many currently used procedures for rectal cancer treatment. The techniques used for local excision include conventional transanal excision, posterior access, therapeutic colonoscopy and transanal endoscopic approaches. The aim of the present study was to present a new surgical proctoscope for the endoscopic transanal excision of rectal lesions. A cylindrical proctoscope with a diameter of 4 cm was devised and built. The end inserted into the anus has a bevelled aspect and rounded borders, allowing correct exposure of the anal lesion. The rectoscope is fixed to the anal border with surgical thread through perforations in the external end. A base screw holds a fibre-light which illuminates the operative field. Part of the equipment is a guide which is positioned inside the rectoscope on insertion into the anus. In operations utilizing this proctoscope, 17 adenomas, 25 adenocarcinomas, 1 carcinoid and 1 endometrioma were excised. The diameter of the lesions varied from 1 to 6 cm. The range of procedures that are possible with this new proctoscope are similar to those achieved with conventional techniques which, however, require more expensive equipment. Hence, the present study demonstrates that this newly devised low-cost proctoscope is an efficient tool for the transanal endoscopic excision of rectal lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study Design. In vitro biomechanical investigation of the screw-holding capacity. Objective. To evaluate the effect of repetitive screw-hole use on the insertional torque and retentive strength of vertebral system screws. Summary and Background Data. Placement and removal of vertebral system screws is sometimes necessary during the surgical procedures in order to assess the walls of the pilot hole. This procedure may compromise the holding capacity of the implant. Methods. Screws with outer diameter measuring 5, 6, and 7 mm were inserted into wood, polyurethane, polyethylene, and cancellous bone cylindrical blocks. The pilot holes were made with drills of a smaller, equal, or wider diameter than the inner screw diameter. Three experimental groups were established based on the number of insertions and reinsertions of the screws and subgroups were created according to the outer diameter of the screw and the diameter of the pilot hole used. Results. A reduction of screw-holding capacity was observed between the first and the following insertions regardless the anchorage material. The pattern of reduction of retentive strength was not similar to the pattern of torque reduction. The pullout strength was more pronounced between the first and the last insertions, while the torque decreased more proportionally from the first to the last insertions. Conclusion. Insertion and reinsertion of the screws of the vertebral fixation system used in the present study reduced the insertion torque and screw purchase.