The Effect of Repetitive Pilot-Hole Use on the Insertion Torque and Pullout Strength of Vertebral System Screws


Autoria(s): DEFINO, Helton L. A.; ROSA, Rodrigo Cesar; SILVA, Patricia; SHIMANO, Antonio Carlos; VOLPON, Jose Batista; PAULA, Francisco Jose Albuquerque de; SCHLEICHER, Philipp; SCHNAKE, Klaus; KANDZIORA, Frank
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2009

Resumo

Study Design. In vitro biomechanical investigation of the screw-holding capacity. Objective. To evaluate the effect of repetitive screw-hole use on the insertional torque and retentive strength of vertebral system screws. Summary and Background Data. Placement and removal of vertebral system screws is sometimes necessary during the surgical procedures in order to assess the walls of the pilot hole. This procedure may compromise the holding capacity of the implant. Methods. Screws with outer diameter measuring 5, 6, and 7 mm were inserted into wood, polyurethane, polyethylene, and cancellous bone cylindrical blocks. The pilot holes were made with drills of a smaller, equal, or wider diameter than the inner screw diameter. Three experimental groups were established based on the number of insertions and reinsertions of the screws and subgroups were created according to the outer diameter of the screw and the diameter of the pilot hole used. Results. A reduction of screw-holding capacity was observed between the first and the following insertions regardless the anchorage material. The pattern of reduction of retentive strength was not similar to the pattern of torque reduction. The pullout strength was more pronounced between the first and the last insertions, while the torque decreased more proportionally from the first to the last insertions. Conclusion. Insertion and reinsertion of the screws of the vertebral fixation system used in the present study reduced the insertion torque and screw purchase.

Identificador

SPINE, v.34, n.9, p.871-876, 2009

0362-2436

http://producao.usp.br/handle/BDPI/23976

10.1097/BRS.0b013e31819e3556

http://dx.doi.org/10.1097/BRS.0b013e31819e3556

Idioma(s)

eng

Publicador

LIPPINCOTT WILLIAMS & WILKINS

Relação

Spine

Direitos

restrictedAccess

Copyright LIPPINCOTT WILLIAMS & WILKINS

Palavras-Chave #spine #bone screws #biomechanics #insertion torque #retentive strength #PEDICLE SCREWS #SPINAL INSTRUMENTATION #LUMBOSACRAL SPINE #LUMBAR SPINE #OUT STRENGTH #FIXATION #TESTS #Clinical Neurology #Orthopedics
Tipo

article

original article

publishedVersion