858 resultados para Unité terminologique prédicative


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to develop an improved support unit cost allocation system for a medium-sized technology company, and to examine which options for overhead cost accounting exist. The study begins with presenting the terminology and methods associated with overhead cost accounting and responsibility accounting. Also the most common challenges and resulting benefits of overhead cost allocation system development are brought up. As one research method two case studies were conducted for benchmarking purposes. These external cases are compared with the principal company’s cost allocation system and reflected against the theoretical background. In the empirical section interviews were used as the primary source of information alongside self studying principal company’s old cost allocation method. Interviews revealed the main weaknesses of the old system and proposals for a new one, which were utilized in setting targets for developing the new system. As a result of the development process an improved support unit cost allocation system was realized for year 2009. The new system is able to handle support unit costs in more detail enhancing the transparency and fairness of resulting cost allocations. Parts of support unit costs are now seen as business units’ own costs rather than group-level overhead. Also recommendations for further development are made after analyzing how well the targets were reached.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the trajectories of the real unit labour costs (RULCs) in a selection of Eurozone economies. Strong asymmetries in the convergence process of the RULCs and its components —real wages, capital intensity, and technology— are uncovered through decomposition and cluster analyses. In the last three decades, the PIIGS (Portugal, Ireland, Italy, Greece, and Spain) succeeded in reducing their RULCs by more than their northern partners. With the exception of Ireland, however, technological progress was weak; it was through capital intensification that periphery economies gained efficiency and competitiveness. Cluster heterogeneity, and lack of robustness in cluster composition, is a reflection of the difficulties in achieving real convergence and, by extension, nominal convergence. We conclude by outlining technology as the key convergence factor, and call for a renewed attention to real convergence indicators to strengthen the process of European integration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of the thesis was to further develop harvester head saw device to the Finnish forest machine manufacturer. The work was done from the basis of the manufacturer´s current production model and the earlier study from this same subject called: “Development of chain saw for harvester” Tero Kaatrasalo, 2004. The work was focused to improving the serviceability and reliability of the saw device, but design also included adding few beforehand determined new features into the saw unit. This was done to give some added value for the end customer. The work includes analysis of the earlier saw devices and ideations of the improvements for the structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of pulp processing on softwood fiber properties strongly influence the properties of wet and dry paper webs. Pulp strength delivery studies have provided observations that much of the strength potential of long fibered pulp is lost during brown stock fiber line operations where the pulp is merely washed and transferred to the subsequent processing stages. The objective of this work was to study the intrinsic mechanisms which maycause fiber damage in the different unit operations of modern softwood brown stock processing. The work was conducted by studying the effects of industrial machinery on pulp properties with some actions of unit operations simulated in laboratory scale devices under controlled conditions. An optical imaging system was created and used to study the orientation of fibers in the internal flows during pulp fluidization in mixers and the passage of fibers through the screen openings during screening. The qualitative changes in fibers were evaluated with existing and standardized techniques. The results showed that each process stage has its characteristic effects on fiber properties: Pulp washing and mat formation in displacement washers introduced fiber deformations especially if the fibers entering the stage were intact, but it did not decrease the pulp strength properties. However, storage chests and pulp transfer after displacement washers contributed to strength deterioration. Pulp screening proved to be quite gentle, having the potential of slightly evening out fiber deformations from very deformed pulps and vice versa inflicting a marginal increase in the deformation indices if the fibers were previously intact. Pulp mixing in fluidizing industrial mixers did not have detrimental effects on pulp strength and had the potential of slightly evening out the deformations, provided that the intensity of fluidization was high enough to allow fiber orientation with the flow and that the time of mixing was short. The chemical and mechanical actions of oxygen delignification had two distinct effects on pulp properties: chemical treatment clearly reduced pulp strength with and without mechanical treatment, and the mechanical actions of process machinery introduced more conformability to pulp fibers, but did not clearly contribute to a further decrease in pulp strength. The chemical composition of fibers entering the oxygen stage was also found to affect the susceptibility of fibers to damage during oxygen delignification. Fibers with the smallest content of xylan were found to be more prone to irreversibledeformations accompanied with a lower tensile strength of the pulp. Fibers poor in glucomannan exhibited a lower fiber strength while wet after oxygen delignification as compared to the reference pulp. Pulps with the smallest lignin content on the other hand exhibited improved strength properties as compared to the references.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this master’s thesis is to develop an algorithm to calculate the cable network for heat and power station CHGRES. This algorithm includes important aspect which has an influence on the cable network reliability. Moreover, according to developed algorithm, the optimal solution for modernization cable system from economical and technical point of view was obtained. The conditions of existing cable lines show that replacement is necessary. Otherwise, the fault situation would happen. In this case company would loss not only money but also its prestige. As a solution, XLPE single core cables are more profitable than other types of cable considered in this work. Moreover, it is presented the dependence of value of short circuit current on number of 10/110 kV transformers connected in parallel between main grid and considered 10 kV busbar and how it affects on final decision. Furthermore, the losses of company in power (capacity) market due to fault situation are presented. These losses are commensurable with investment to replace existing cable system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the numerous approaches to food waste treatment, the food waste disposers method (FWDs), as a newcomer, has become slowly accepted by the general public owing to the worries about its impact on the existing sewage system. This paper aims to justify the role of FWDs in the process of urbanization in order to better prepare a city to take good care of the construction of its infrastructure and the solid waste treatment. Both the literatures and the case study help to confirm that FWDs has no negative effects on the wastewater treatment plant and it is also environmental friendly by reducing the greenhouse gas emissions. In the case study, the Lappeenranta waste water treatment plant has been selected in order to figure out the possible changes to a WWTP following the integration of FWDs: the observation shows only minor changes take place in a WWTP, in case of 25% application, like BOD up 7%, TSS up 6% and wastewater flowrate up 6%, an additional sludge production of 200 tons per year and the extra yield of methane up to 10000m3 per year; however, when the utilization rate of FWD is over 75%, BOD, TSS, and wastewater flowrate will experience more significant changes, thus exerting much pressure on the existing WWTP. FWDs can only be used in residential areas or cities equipped with consummate drainage network within the service sphere of WWTP, therefore, the relevant authority or government department should regulate the installation frequency of FWDs, while promoting the accessory application of FWDs. In the meanwhile, WWTP should improve their treatment process in order to expand their capacity for sludge treatment so as to stay in line with the future development of urban waste management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the advent of mechanized farming and intensive use of agricultural machinery and implements on the properties, the soil began to receive greater load of machinery traffic, which can cause increased soil compaction. The aim of this study was to evaluate the spatial variability of soil mechanical resistance to penetration (RP) in the layers of 0.00-0.10, 0.10-0.20, 0.20-0.30 and 0.30-0.40m, using geostatistics in an area cultivated with mango in Haplic Vertisol of the northeastern semi-arid, with mobile unit equipped with electronic penetrometer. The RP data was collected in 56 points from an area of 3 ha, and random soil samples were collected to determine the soil moisture and texture. For RP data analysis we used descriptive statistics and geostatistics. The soil mechanical resistance to penetration presented increased variability, with adjustment of the spherical and exponential semivariograms in the layers. We found that 42% of the area in the layer of 0.10-0.20m showed RP values above 2.70 MPa. Maximum values of RP were found in the layer of 0.19-0.27m, predominantly in 56% of the area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this doctoral thesis, a power conversion unit for a 10 kWsolid oxide fuel cell is modeled, and a suitable control system is designed. The need for research was identified based on an observation that there was no information available about the characteristics of the solid oxide fuel cell from the perspective of power electronics and the control system, and suitable control methods had not previously been studied in the literature. In addition, because of the digital implementation of the control system, the inherent characteristics of the digital system had to be taken into account in the characteristics of the solid oxide fuel cell (SOFC). The characteristics of the solid oxide fuel cell as well the methods for the modeling and control of the DC/DC converter and the grid converter are studied by a literature survey. Based on the survey, the characteristics of the SOFC as an electrical power source are identified, and a solution to the interfacing of the SOFC in distributed generation is proposed. A mathematical model of the power conversion unit is provided, and the control design for the DC/DC converter and the grid converter is made based on the proposed interfacing solution. The limit cycling phenomenon is identified as a source of low-frequency current ripple, which is found to be insignificant when connected to a grid-tied converter. A method to mitigate a second harmonic originating from the grid interface is proposed, and practical considerations of the operation with the solid oxide fuel cell plant are presented. At the theoretical level, the thesis discusses and summarizes the methods to successfully derive a model for a DC/DC converter, a grid converter, and a power conversion unit. The results of this doctoral thesis can also be used in other applications, and the models and methods can be adopted to similar applications such as photovoltaic systems. When comparing the results with the objectives of the doctoral thesis, we may conclude that the objectives set for the work are met. In this doctoral thesis, theoretical and practical guidelines are presented for the successful control design to connect a SOFC-based distributed generation plant to the utility grid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this thesis is to examine what the normative, effective social Intranet solution is for Tellabs Mobile Routing business unit in terms of sharing knowledge more openly and effectively, fostering innovation, and improving team spirit and positive employee experience. Additionally, these aspects are researched from the intra- and inter-organizational points of view. The research is based on previous literature and empirical interviews. Based on these two items, an eight-fold recommendation proposal was created to change the current Intranet to become an effective social Intranet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 1011 ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 µs) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine if the diagnostic profile of inpatients of a psychiatric unit in a general hospital influences the length of stay. The results of a retrospective survey comprising the first 16 years of operation of the Psychiatric Unit of the Ribeirão Preto General Hospital (PURP) showed that the progressive increase observed in the length of stay correlated with the increase in percentage of schizophrenia diagnosis, after the 8th year of hospital operation, and of affective disorders, after the 12th year. The length of hospitalization kept increasing until the 16th year, even though there was no change in the diagnostic profile of the patients admitted to the unit. In a prospective study encompassing the next six months, 61 inpatients were evaluated with the Structured Clinical Interview for DSM-III-R and the Brief Psychiatric Rating Scale (BPRS). The results showed that 82% of the inpatients fulfilled the diagnostic criteria for the schizophrenic or affective disorder spectrum at admission, with a discharge rate slower than for other diagnoses, although the length of hospitalization did not significantly differ among diagnostic categories. The results further demonstrated that in every diagnostic category more than 50% of the patients stayed in hospital for more than one week after reaching a BPRS score equal to 6, indicative of discharge. Overall, these data suggest that the increase in length of hospitalization may be due to a higher percentage of patients with a diagnosis of schizophrenia and affective disorder admitted to the PURP. In addition, patients with low symptomatic levels remained in hospital longer than they should have.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalent rate of psychiatry morbidity amongst patients with cancer reported in various studies ranges from 5 to 50%, a variation that can be attributed to differences in sample size, the disease itself and treatment factors. The objectives of the present study were to determine the frequency of psychiatric morbidity amongst recently diagnosed cancer outpatients and try to identify which factors might be related to further psychological distress. Two hundred and eleven (70.9%) female patients and 87 (29.1%) male patients from the chemotherapy unit of the Cancer Hospital A.C. Camargo (São Paulo) completed a questionnaire that featured data on demographic, medical and treatment details. The Self Reporting Questionnaire (SRQ-20) was administered to the patients to determine their personal psychiatric morbidity. Seventy-two patients (25.8%) scored > or = 8 in the SRQ-20, the cut-off point for a patient to be considered a psychiatric case. When the low and high scoring groups were compared no differences were detected regarding age, marital status, tumor site, sex, or previous treatment. Nonetheless, patients in the lowest social class and those who were bedridden less than 50% of the time had a significantly higher probability of being a psychiatric case. Regarding help-seeking behavior in situations in which they had doubts or were frightened, about 64% of the total sample did not seek any type of support and did not talk to anyone. This frequency of psychiatric morbidity agrees with data from the cancer literature. According to many investigators, the early detection of a comorbid psychiatric disorder is crucial to relieve a patient's suffering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to assess the incidence, risk factors and outcome of patients who develop acute renal failure (ARF) in intensive care units. In this prospective observational study, 221 patients with a 48-h minimum stay, 18-year-old minimum age and absence of overt acute or chronic renal failure were included. Exclusion criteria were organ donors and renal transplantation patients. ARF was defined as a creatinine level above 1.5 mg/dL. Statistics were performed using Pearsons' chi2 test, Student t-test, and Wilcoxon test. Multivariate analysis was run using all variables with P < 0.1 in the univariate analysis. ARF developed in 19.0% of the patients, with 76.19% resulting in death. Main risk factors (univariate analysis) were: higher intra-operative hydration and bleeding, higher death risk by APACHE II score, logist organ dysfunction system on the first day, mechanical ventilation, shock due to systemic inflammatory response syndrome (SIRS)/sepsis, noradrenaline use, and plasma creatinine and urea levels on admission. Heart rate on admission (OR = 1.023 (1.002-1.044)), male gender (OR = 4.275 (1.340-13642)), shock due to SIRS/sepsis (OR = 8.590 (2.710-27.229)), higher intra-operative hydration (OR = 1.002 (1.000-1004)), and plasma urea on admission (OR = 1.012 (0.980-1044)) remained significant (multivariate analysis). The mortality risk factors (univariate analysis) were shock due to SIRS/sepsis, mechanical ventilation, blood stream infection, potassium and bicarbonate levels. Only potassium levels remained significant (P = 0.037). In conclusion, ARF has a high incidence, morbidity and mortality when it occurs in intensive care unit. There is a very close association with hemodynamic status and multiple organ dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to retrospectively report the results of interventions for controlling a vancomycin-resistant enterococcus (VRE) outbreak in a tertiary-care pediatric intensive care unit (PICU) of a University Hospital. After identification of the outbreak, interventions were made at the following levels: patient care, microbiological surveillance, and medical and nursing staff training. Data were collected from computer-based databases and from the electronic prescription system. Vancomycin use progressively increased after March 2008, peaking in August 2009. Five cases of VRE infection were identified, with 3 deaths. After the interventions, we noted a significant reduction in vancomycin prescription and use (75% reduction), and the last case of VRE infection was identified 4 months later. The survivors remained colonized until hospital discharge. After interventions there was a transient increase in PICU length-of-stay and mortality. Since then, the use of vancomycin has remained relatively constant and strict, no other cases of VRE infection or colonization have been identified and length-of-stay and mortality returned to baseline. In conclusion, we showed that a bundle intervention aiming at a strict control of vancomycin use and full compliance with the Hospital Infection Control Practices Advisory Committee guidelines, along with contact precautions and hand-hygiene promotion, can be effective in reducing vancomycin use and the emergence and spread of vancomycin-resistant bacteria in a tertiary-care PICU.