883 resultados para ORTHOPAEDIC FIXATION DEVICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the behavior of complex information in the Fresnel domain, taking into account the limited capability to display complex values of liquid crystal devices when they are used as holographic displays. To do this analysis we study the reconstruction of Fresnel holograms at several distances using the different parts of the complex distribution. We also use the information adjusted with a method that combines two configurations of the devices in an adding architecture. The results of the error analysis show different behavior for the reconstructions when using the different methods. Simulated and experimental results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quartz Tuning Fork (QTF)-based Scanning Probe Microscopy (SPM) is an important field of research. A suitable model for the QTF is important to obtain quantitative measurements with these devices. Analytical models have the limitation of being based on the double cantilever configuration. In this paper, we present an electromechanical finite element model of the QTF electrically excited with two free prongs. The model goes beyond the state-of-the-art of numerical simulations currently found in the literature for this QTF configuration. We present the first numerical analysis of both the electrical and mechanical behavior of QTF devices. Experimental measurements obtained with 10 units of the same model of QTF validate the finite element model with a good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mobile technologies have brought about major changes in police equipment and police work. If a utopian narrative remains strongly linked to the adoption of new technologies, often formulated as 'magic bullets' to real occupational problems, there are important tensions between their 'imagined' outcomes and the (unexpected) effects that accompany their daily 'practical' use by police officers. This article offers an analysis of police officers' perceptions and interactions with security devices. In so doing, it develops a conceptual typology of strategies for coping with new technology inspired by Le Bourhis and Lascoumes: challenging, neutralizing and diverting. To that purpose, we adopt an ethnographic approach that focuses on the discourses, practices and actions of police officers in relation to three security devices: the mobile digital terminal, the mobile phone and the body camera. Based on a case study of a North American municipal police department, the article addresses how these technological devices are perceived and experienced by police officers on the beat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Time to fitness for work (TFW) was measured as the number of days that were paid as compensation for work disability during the 4 years after discharge from the rehabilitation clinic in a population of patients hospitalised for rehabilitation after orthopaedic trauma. The aim of this study was to test whether some psychological variables can be used as potential early prognostic factors of TFW. MATERIAL AND METHODS: A Cox proportional hazards model was used to estimate the associations between predictive variables and TFW. Predictors were global health, pain at hospitalisation and pain decrease during the stay (all continuous and standardised by subtracting the mean and dividing by two standard deviations), perceived severity of the trauma and expectation of a positive evolution (both binary variables). RESULTS: Full data were available for 807 inpatients (660 men, 147 women). TFW was positively associated with better perceived health (hazard ratio [HR] 1.16, 95% confidence interval [CI] 1.13-1.19), pain decrease (HR 1.46, 95% CI 1.30-1.64) and expectation of a positive evolution (HR 1.50, 95% CI 1.32-1.70) and negatively associated with pain at hospitalisation (HR 0.67, 95% CI 0.59-0.76) and high perceived severity (HR 0.72, 95% CI 0.61-0.85). DISCUSSION: The present results provide some evidence that work disability during a four-year period after rehabilitation may be predicted by prerehabilitation perceptions of general health, pain, injury severity, as well as positive expectation of evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study has been to make a profitability analysis of service contracts for a company in Finland. The purpose has been to see how profitable the contracts are and if there possibly were some things to change or develop in the contracts. Allocation rules of cost accounting, service costs both profitability and management of services have been considered in the theory part. All the service contracts that have been valid at least three last accounting periods have been included in the study. All direct costs relating to the contracts have been collected and indirect costs have been assigned to the contracts. Profitability of the contracts has been calculated over three years. Results have been analyzed according to the key figures the company is controlling. Some suggestions for developments have been given at the end of the study. The study has shown differences between the contracts. Part of them has turned out to be like the profitability aims of the company and part less profitable. The study has shown that many factors have an effect on the profitability of the service contracts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les pistolets à impulsion électrique (PIE) sont de plus en plus fréquemment utilisés en Europe ces dernières années, le modèle le plus connu étant le Taser®. Les connaissances scientifiques concernant les PIE et leurs effets potentiels restent toutefois limitées. Nous avons conduit une revue de littérature afin d'évaluer les implications potentielles de leur utilisation en termes de sécurité, de morbidité et de mortalité. Une exposition unique chez un individu sain peut généralement être considérée comme peu dangereuse. Les sujets à risque de complications sont les individus exposés à de multiples décharges, les personnes sous l'influence de substances psychoactives, ceux qui montrent des signes d'agitation extrême, ou encore les individus présentant des comorbidités médicales. L'éventail des complications pouvant survenir lors de leur exposition est large et inclut les lésions provoquées par les impacts des électrodes, les traumatismes liés à la chute induite par la paralysie transitoire ou des complications cardiovasculaires. Dans ce contexte, les personnes exposées doivent être examinées attentivement, et les éventuelles lésions traumatiques doivent être exclues. The use of electronic control devices (ECD), such as the Taser®, has increased in Europe over the past decade. However, scientific data concerning the potential health impact of ECD usage remains limited. We reviewed the scientific literature in order to evaluate the safety, mortality, and morbidity associated with ECD use. Exposure of a healthy individual to a single ECD electroshock can be considered generally safe. Complications can, however, occur if the patient is subject to multiple electroshocks, if the patient has significant medical comorbidities, or when exposure is associated with drug abuse or agitated delirium. The broad spectrum of potential complications associated with ECD exposure includes direct trauma caused by the ECD electrodes, injuries caused by the transient paralysis-induced fall, and cardiovascular events. An ECD-exposed patient requires careful examination during which traumatic injuries are actively sought out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two enoxaparin dosage regimens are used as comparators to evaluate new anticoagulants for thromboprophylaxis in patients undergoing major orthopaedic surgery, but so far no satisfactory direct comparison between them has been published. Our objective was to compare the efficacy and safety of enoxaparin 3,000 anti-Xa IU twice daily and enoxaparin 4,000 anti-Xa IU once daily in this clinical setting by indirect comparison meta-analysis, using Bucher's method. We selected randomised controlled trials comparing another anticoagulant, placebo (or no treatment) with either enoxaparin regimen for venous thromboembolism prophylaxis after hip or knee replacement or hip fracture surgery, provided that the second regimen was assessed elsewhere versus the same comparator. Two authors independently evaluated study eligibility, extracted the data, and assessed the risk of bias. The primary efficacy outcome was the incidence of venous thomboembolism. The main safety outcome was the incidence of major bleeding. Overall, 44 randomised comparisons in 56,423 patients were selected, 35 being double-blind (54,117 patients). Compared with enoxaparin 4,000 anti-Xa IU once daily, enoxaparin 3,000 anti-Xa IU twice daily was associated with a reduced risk of venous thromboembolism (relative risk [RR]: 0.53, 95% confidence interval [CI]: 0.40 to 0.69), but an increased risk of major bleeding (RR: 2.01, 95% CI: 1.23 to 3.29). In conclusion, when interpreting the benefit-risk ratio of new anticoagulant drugs versus enoxaparin for thromboprophylaxis after major orthopaedic surgery, the apparently greater efficacy but higher bleeding risk of the twice-daily 3,000 anti-Xa IU enoxaparin regimen compared to the once-daily 4,000 anti-Xa IU regimen should be taken into account.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the health domain, the field of rehabilitation suffers from a lack specialized staff while hospital costs only increase. Worse, almost no tools are dedicated to motivate patients or help the personnel to carry out monitoring of therapeutic exercises. This paper demonstrates the high potential that can bring the virtual reality with a platform of serious games for the rehabilitation of the legs involving a head-mounted display and haptic robot devices. We first introduce SG principles and the current context regarding rehabilitation interventions followed by the description of an original haptic device called Lambda Health System. The architecture of the model is then detailed, including communication specifications showing that lag is imperceptible for user (60Hz). Finally, four serious games for rehabilitation using haptic robots and/or HMD were tested by 33 health specialists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to assess the results of labyrinthine fenestration for fixed stapes in chronic ear disease. Using a prospective database, pre- and postoperative audiometric data from patients undergoing labyrinthine fenestration for fixation of the stapes in chronic ear disease others than otosclerosis between 2002 and 2012 were evaluated. Twenty-three labyrinthine fenestrations in chronic ear disease were performed (17 malleo-stapedotomies, 4 incus-stapedotomies, 1 neo-malleus-stapedotomy, 1 TORP-stapedotomy). Overall, the mean short-term (2 months) and long-term (42 months) postoperative air-bone gap (0.5-3 kHz) were 17.5 and 16.5 dB, respectively; long-term air-bone gap of <20 dB was obtained in 73 % of patients. There was no significant difference in air-bone gap closure between tympanosclerotic and post inflammatory osteogenic fixation of the stapes (p = 0.267). Hearing benefit success using the 'Belfast rule of the thumb' was achieved in 48 %. Normal bilateral hearing was achieved in 17 % and bilateral symmetric hearing impairment in 26 %. Only in 4 %, bone conduction worsened by more than 5 dB. Labyrinthine fenestration is an option in selected cases of stapes fixation in chronic ear disease and provides hearing gain without significant risk for sensorineural hearing loss. In those already selected cases, hearing benefit success 'Belfast rule of the thumb' is achieved only in half of the cases. This and the possible alternatives, should therefore be discussed preoperatively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context awareness is emerging on mobile devices. Context awareness can be used to improve usability of a mobile device. Context awareness is particularly important on mobile devices due the limitations they have. At first in this work, a literature review on context awareness and mobile environment is made. For aiding context awareness there exist an implementation of a Context Framework for Symbian S60 devices. It provides a possibility for exchanging the contexts inside the device between the client applications of the local Context Framework. The main contribution of this thesis is to design and implement an enhancement to the S60 Context Framework for providing possibility to exchange context over device boundaries. Using the implemented Context Exchange System, the context exchange is neither depending on the type of the context nor the type of the client. In addition, the clients and the contexts can reside on any interconnected device. The usage of the system is independent of the programming language since in addition to using only Symbian C++ function interfaces it can also be utilized using XML scripts. The Meeting Sniffer application, which uses the Context Exchange System, was also developed in this work. Using this application, it is possible to recognize a meeting situation and suggest device profile change to a user.