814 resultados para Computer- aided Engineering


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The organisation of cells of the planctomycete species Pirellula marina, Isosphaera pallida, Gemmata obscuriglobus, Planctomyces mat-is and Candidatus Brocadia anammoxidans was investigated based on ultrastructure derived from thin-sections of cryosubstituted cells, freeze-fracture replicas, and in the case of Gemmata obscuriglobus and Pirellllla marina, computer-aided 3-D reconstructions from serial sections of cryosubstituted cells. All planctomycete cells display a peripheral ribosome-free region, termed here the paryphoplasm, surrounding the perimeter of the cell, and an interior region including any nucleoid regions as well as ribosome-like particles, bounded by a single intracytoplasmic membrane (ICM), and termed the pirellulosome in Pirellula species. Immunogold labelling and RNase-gold cytochemistry indicates that in planctomycetes all the cell DNA is contained wholly within the interior region bounded by the ICM, and the paryphoplasm contains no DNA but at least some of the cell's RNA. The ICM in Isosphaera pallida and Planctomyces mat-is is invaginated such that the paryphoplasm forms a major portion of the cell interior in sections, but in other planctomycetes it remains as a peripheral zone. In the anaerobic ammonium-oxidising (anammox process) chemoautotroph Candidatus Brocadia anammoxidans the interior region bounded by ICM contains a further internal single-membrane-bounded region, the anam-moxosome. In Gemmata obscuriglobus. the interior ICM-bounded region contains the nuclear body, a double-membrane-bounded region containing the cell's nucleoid and all genomic DNA in addition to some RNA. Shared features of cell compartmentalisation in different planctomycetes are consistent with the monophyletic nature of the planctomycetes as a distinct division of the Bacteria. The shared organisational plan for the planctomycete cell constitutes a new type not known in cells of other bacteria.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recentemente, a expans??o do n??mero de munic??pios conveniados com a FNS fez aumentar a demanda por novos projetos de melhoria dos sistemas de ??gua e esgotos. Ao mesmo tempo, a FNS enfrentava car??ncia de pessoal t??cnico especializado, dificuldades de admiss??o de novos profissionais e limita????o de recursos para a contrata????o de projetos atrav??s de empresas privadas, inviabilizando o atendimento das demandas pela forma tradicional. Diante disso, servidores da FNS desenvolveram um software para projetos de redes de esgotos sanit??rios, utilizando os recursos modernos da computa????o gr??fica (CAD ??? Computer Aided Design). Acoplado ao CAD, prop??s-se a cria????o de um m??dulo de dimensionamento, resultando numa ferramenta completa de elabora????o de projetos, em ambiente computacional Windows, contemplando as v??rias etapas t??picas de um trabalho na ??rea, desde a digitaliza????o do levantamento topogr??fico, lan??amento da rede, c??lculos, planilhas, desenho e montagem final das pranchas geradas. Este sistema foi denominado Sancad. A utiliza????o do Sancad permitiu uma redu????o m??dia de 60 a 70% no tempo de elabora????o de projetos, significando uma forma de atender a um n??mero maior de demandas e de suprir a car??ncia de profissionais na FNS. Al??m disso, a utiliza????o do Sancad tem mostrado ganhos em termos de qualidade, corre????o e confiabilidade do produto final obtido. As previs??es iniciais quanto ?? abrang??ncia de utiliza????o do Sancad foram amplamente superadas, tendo o mesmo se tornado um padr??o para a ??rea de projetos de saneamento da FNS, estando instalado em 12 unidades da Funda????o em todo o Brasil e em processo de instala????o em outras. O Sancad tornou-se objeto de interesse de t??cnicos de saneamento e de estudantes de engenharia e arquitetura de institui????es p??blicas e privadas, que receberam treinamento a fim de conhec??-lo e utiliz??-lo. Finalmente, o sucesso da experi??ncia tem contribu??do para a dissemina????o da cultura de computa????o gr??fica e a ades??o dos profissionais da FNS e das autarquias municipais conveniadas ?? nova tecnologia. Neste mesmo sentido, ressalta-se a utiliza????o de teodolitos eletr??nicos ??? conhecidos como Esta????o Total ??? para a gera????o de plantas topogr??ficas j?? em formato digital, para serem usadas pelo Sancad, com novos ganhos de qualidade e produtividade na elabora????o dos projetos de saneamento

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

March 19 - 22, 2006, São Paulo, BRAZIL World Congress on Computer Science, Engineering and Technology Education

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An increasing amount of research is being developed in the area where technology and humans meet. The success or failure of technologies and the question whether technology helps humans to fulfill their goals or whether it hinders them is in most cases not a technical one. User Perception and Influencing Factors of Technology in Everyday Life addresses issues of human and technology interaction. The research in this work is interdisciplinary, ranging from more technical subjects such as computer science, engineering, and information systems, to non-technical descriptions of technology and human interaction from the point of view of sociology or philosophy. This book is perfect for academics, researchers, and professionals alike as it presents a set of theories that allow us to understand the interaction of technology and humans and to put it to practical use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The way humans interact with technology is undergoing a tremendous change. It is hard to imagine the lives we live today without the benefits of technology that we take for granted. Applying research in computer science, engineering, and information systems to non-technical descriptions of technology, such as human interaction, has shaped and continues to shape our lives. Human Interaction with Technology for Working, Communicating, and Learning: Advancements provides a framework for conceptual, theoretical, and applied research in regards to the relationship between technology and humans. This book is unique in the sense that it does not only cover technology, but also science, research, and the relationship between these fields and individuals' experience. This book is a must have for anyone interested in this research area, as it provides a voice for all users and a look into our future.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the development of a solar photovoltaic (PV) model based on PSCAD/EMTDC - Power System Computer Aided Design – including a mathematical model study. An additional algorithm has been implemented in MATLAB software in order to calculate several parameters required by the PSCAD developed model. All the simulation study has been performed in PSCAD/MATLAB software simulation tool. A real data base concerning irradiance, cell temperature and PV power generation was used in order to support the evaluation of the implemented PV model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Imagem Digital por Radiação X.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Fatty liver disease (FLD) is an increasing prevalent disease that can be reversed if detected early. Ultrasound is the safest and ubiquitous method for identifying FLD. Since expert sonographers are required to accurately interpret the liver ultrasound images, lack of the same will result in interobserver variability. For more objective interpretation, high accuracy, and quick second opinions, computer aided diagnostic (CAD) techniques may be exploited. The purpose of this work is to develop one such CAD technique for accurate classification of normal livers and abnormal livers affected by FLD. METHODS: In this paper, the authors present a CAD technique (called Symtosis) that uses a novel combination of significant features based on the texture, wavelet transform, and higher order spectra of the liver ultrasound images in various supervised learning-based classifiers in order to determine parameters that classify normal and FLD-affected abnormal livers. RESULTS: On evaluating the proposed technique on a database of 58 abnormal and 42 normal liver ultrasound images, the authors were able to achieve a high classification accuracy of 93.3% using the decision tree classifier. CONCLUSIONS: This high accuracy added to the completely automated classification procedure makes the authors' proposed technique highly suitable for clinical deployment and usage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

E-Learning frameworks are conceptual tools to organize networks of elearning services. Most frameworks cover areas that go beyond the scope of e-learning, from course to financial management, and neglects the typical activities in everyday life of teachers and students at schools such as the creation, delivery, resolution and evaluation of assignments. This paper presents the Ensemble framework - an e-learning framework exclusively focused on the teaching-learning process through the coordination of pedagogical services. The framework presents an abstract data, integration and evaluation model based on content and communications specifications. These specifications must base the implementation of networks in specialized domains with complex evaluations. In this paper we specialize the framework for two domains with complex evaluation: computer programming and computer-aided design (CAD). For each domain we highlight two Ensemble hotspots: data and evaluations procedures. In the former we formally describe the exercise and present possible extensions. In the latter, we describe the automatic evaluation procedures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rationale and Objectives Computer-aided detection and diagnosis (CAD) systems have been developed in the past two decades to assist radiologists in the detection and diagnosis of lesions seen on breast imaging exams, thus providing a second opinion. Mammographic databases play an important role in the development of algorithms aiming at the detection and diagnosis of mammary lesions. However, available databases often do not take into consideration all the requirements needed for research and study purposes. This article aims to present and detail a new mammographic database. Materials and Methods Images were acquired at a breast center located in a university hospital (Centro Hospitalar de S. João [CHSJ], Breast Centre, Porto) with the permission of the Portuguese National Committee of Data Protection and Hospital's Ethics Committee. MammoNovation Siemens full-field digital mammography, with a solid-state detector of amorphous selenium was used. Results The new database—INbreast—has a total of 115 cases (410 images) from which 90 cases are from women with both breasts affected (four images per case) and 25 cases are from mastectomy patients (two images per case). Several types of lesions (masses, calcifications, asymmetries, and distortions) were included. Accurate contours made by specialists are also provided in XML format. Conclusion The strengths of the actually presented database—INbreast—relies on the fact that it was built with full-field digital mammograms (in opposition to digitized mammograms), it presents a wide variability of cases, and is made publicly available together with precise annotations. We believe that this database can be a reference for future works centered or related to breast cancer imaging.