963 resultados para Sensitivity and specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the accuracy of sonographic endometrial thickness and hysteroscopic characteristics in predicting malignancy in postmenopausal women undergoing surgical resection of endometrial polyps. METHODS: Five hundred twenty-one (521) postmenopausal women undergoing hysteroscopic resection of endometrial polyps between January 1998 and December 2008 were studied. For each value of sonographic endometrial thickness and polyp size on hysteroscopy, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated in relation to the histologic diagnosis of malignancy. The best values of sensitivity and specificity for the diagnosis of malignancy were determined by the Receiver Operating Characteristic (ROC) curve. RESULTS: Histologic diagnosis identified the presence of premalignancy or malignancy in 4.1% of cases. Sonographic measurement revealed a greater endometrial thickness in cases of malignant polyps when compared to benign and premalignant polyps. On surgical hysteroscopy, malignant endometrial polyps were also larger. An endometrial thickness of 13 mm showed a sensitivity of 69.6%, specificity of 68.5%, PPV of 9.3%, and NPV of 98% in predicting malignancy in endometrial polyps. Polyp measurement by hysteroscopy showed that for polyps 30 mm in size, the sensitivity was 47.8%, specificity was 66.1%, PPV was 6.1%, and NPV was 96.5% for predicting cancer. CONCLUSIONS: Sonographic endometrial thickness showed a higher level of accuracy than hysteroscopic measurement in predicting malignancy in endometrial polyps. Despite this, both techniques showed low accuracy for predicting malignancy in endometrial polyps in postmenopausal women. In suspected cases, histologic evaluation is necessary to exclude malignancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of this longitudinal study was to investigate the value of uterine artery Doppler sonography during the second and third trimesters in the prediction of adverse pregnancy outcome in low-risk women. METHODS: From July 2011 to August 2012, a total of 205 singleton pregnant women presenting at our antenatal clinic were enrolled in this prospective study and were assessed for baseline demographic and obstetric data. They underwent ultrasound evaluation at the time of second and third trimesters, both included Doppler assessment of bilateral uterine arteries to determine the values of the pulsatility index (PI) and resistance index (RI) and presence of early diastolic notch. The endpoint of this study was assessing the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasonography of the uterine artery, for the prediction of adverse pregnancy outcomes including preeclampsia, stillbirth, placental abruption and preterm labor. RESULTS: The mean age of cases was 26.4±5.11. The uterine artery PI and RI values for both second (PI: 1.1±0.42 versus 1.53±0.59, p=0.002; RI: 0.55±0.09 versus 0.72±0.13, p=0.000 respectively) and third-trimester (PI: 0.77±0.31 versus 1.09±0.46, p=0.000; RI: 0.46±0.10 versus 0.60±0.14, p=0.010 respectively) evaluations were significantly higher in patients with adverse pregnancy outcome than in normal women. Combination of PI and RI >95th percentile and presence of bilateral notch in second trimester get sensitivity and specificity of 36.1 and 97% respectively, while these measures were 57.5 and 98.2% in third trimester. CONCLUSIONS: According to our study, it seems that uterine artery Doppler may be a valuable tool for the prediction of a variety of adverse outcomes in second and third trimesters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To compare the diagnostic accuracy of the classic Meisels cytologic criteria and the Schneider secondary criteria relative to the hybrid capture method for diagnosing HPV infection. Methods This was a retrospective study performed at a public university hospital. A total of 41 patients with a cytologic diagnosis of HPV infection and 40 HPV-negative patients were selected for review of the cervical-vaginal smears seeking to classical and secondary criteria. A single pathologist reviewed the slides in search of the criteria. The classical and secondary cytologic criteria were compared with the hybrid capture for diagnosing HPV infection. Bartleti test was applied for the age analysis, and Fisher's exact test was used to compare proportions. The tests were considered significant when the probability of rejecting the null hypothesis was less than 5% (p < 0.05). Results The Meisels criteria were less sensitive (34.0%) than the secondary Schneider criteria (57.5%) when compared with the hybrid capture (p < 0.0001), although the specificity of the former criteria was non-significantly higher (91.2% and 67.7%, respectively). In cases of moderate or intense inflammation, the sensitivity and specificity of the Schneider criteria were decreased, 33.3% and 50.0% respectively (p = 0.0115). Conclusions Compared with hybrid capture for diagnosis of HPV infection, the sensitivity of the secondary Schneider criteria was higher than the classical Meisels criteria.Moderate or intense inflammation reduces the sensitivity and specificity of the secondary Schneider criteria for diagnosing HPV infection using the hybrid capture as the gold standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study determined the sensitivity and specificity of the indirect fluorescent antibody test (IFAT) and modified agglutination test (MAT) for anti-Toxoplasma gondii antibody detection by analyzing sera from 46 experimentally infected pigs. Values for sensitivity were 95.7% (confidence interval 95%: 84.0-99.2%) and for specificity 97.8% (confidence interval 95%: 87.0-99.9%) in both tests. There was an optimum agreement of results between IFAT and MAT evidenced by a Kappa test of 0.86. These results validate these tests for the detection of T. gondii infection in pigs. IFAT and MAT despite methodologies with different characteristics and readings have similar accuracy in pig serum samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional PCR (PCRTeq) for diagnosing Theileria equi and multiplex PCR (M/PCRTeq-Bc) for diagnosing T. equi and Babesia caballi were comparatively evaluated with nested PCR (N/PCR-Teq) for diagnosing equine piroplasmosis. In DNA sensitivity determinations, in multiple dilutions of equine blood that had tested positive for T. equi, PCR-Teq and N/PCR-Teq detected hemoparasite DNA in the larger dilutions (1:128), but did not differ significantly from the M/PCRTeq-Bc (1:64). In analyses on equine serum tested by ELISA, there was high agreement between this serological test and PCR-Teq (k = 0.780) and moderate agreement with N/PCR-Teq (k = 0.562) and M/PCRTeq-Bc (k = 0.488). PCR-Teq found a higher frequency of T. equi both in extensively and intensively reared horses, but this was not significant in relation to N/PCR-Teq (P>0.05), and both PCRs indicated that there was an endemic situation regarding T. equi in the population of horses of this sample. PCR-Teq was only significantly different from M/PCR-Teq-Bc (P<0.05). PCR-Teq presented high sensitivity and specificity, comparable to N/PCR-Teq, but with the advantage of higher speed in obtaining results and lower costs and risks of laboratory contamination. This accredits PCR-Teq for epidemiological studies and for determinations on affected horses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the interference of tuberculin test on the gamma-interferon (INFg) assay, to estimate the sensitivity and specificity of the INFg assay in Brazilian conditions, and to simulate multiple testing using the comparative tuberculin test and the INFg assay. Three hundred-fifty cattle from two TB-free and two TB-infected herds were submitted to the comparative tuberculin test and the INFg assay. The comparative tuberculin test was performed using avian and bovine PPD. The INFg assay was performed by the BovigamTM kit (CSL Veterinary, Australia), according to the manufacturer's specifications. Sensitivity and specificity of the INFg assay were assessed by a Bayesian latent class model. These diagnostic parameters were also estimate for multiple testing. The results of INFg assay on D0 and D3 after the comparative tuberculin test were compared by the McNemar's test and kappa statistics. Results of mean optical density from INFg assay on both days were similar. Sensitivity and specificity of the INFg assay showed results varying (95% confidence intervals) from 72 to 100% and 74 to 100% respectively. Sensitivity of parallel testing was over 97.5%, while specificity of serial testing was over 99.7%. The INFg assay proved to be a very useful diagnostic method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conidiobolomycosis is a granulomatous disease caused by the fungus Conidiobolus spp. in humans and animals. Traditional technique for diagnosis of the disease is isolation of the agent associated with the presence of typical clinical signs and pathological conditions. The aim of this study was to describe the development of a specific polymerase chain reaction (PCR) test for Conidiobolus lamprauges to detect the fungus in clinical samples. Samples from suspected animals were collected and submitted to isolation, histopathological analysis and amplification by PCR. DNA from tissues was subjected to PCR with fungi universal primers 18S rDNA gene, and specific primers were designed based on the same gene in C. lamprauges that generated products of about 540 bp and 222 bp respectively. The culture was positive in 26.6% of clinical samples. The PCR technique for C. lamprauges showed amplification of DNA from fresh tissues (80%) and paraffin sections (44.4%). In conclusion, the PCR technique described here demonstrated a high sensitivity and specificity for detection of fungal DNA in tissue samples, providing a tool for the rapid diagnosis of C. lamprauges.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of the present study was to evaluate the diagnostic value (clinical application) of brain measures and cognitive function. Alzheimer and multiinfarct patients (N = 30) and normal subjects over the age of 50 (N = 40) were submitted to a medical, neurological and cognitive investigation. The cognitive tests applied were Mini-Mental, word span, digit span, logical memory, spatial recognition span, Boston naming test, praxis, and calculation tests. The brain ratios calculated were the ventricle-brain, bifrontal, bicaudate, third ventricle, and suprasellar cistern measures. These data were obtained from a brain computer tomography scan, and the cutoff values from receiver operating characteristic curves. We analyzed the diagnostic parameters provided by these ratios and compared them to those obtained by cognitive evaluation. The sensitivity and specificity of cognitive tests were higher than brain measures, although dementia patients presented higher ratios, showing poorer cognitive performances than normal individuals. Normal controls over the age of 70 presented higher measures than younger groups, but similar cognitive performance. We found diffuse losses of tissue from the central nervous system related to distribution of cerebrospinal fluid in dementia patients. The likelihood of case identification by functional impairment was higher than when changes of the structure of the central nervous system were used. Cognitive evaluation still seems to be the best method to screen individuals from the community, especially for developing countries, where the cost of brain imaging precludes its use for screening and initial assessment of dementia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measuring protein biomarkers from sample matrix, such as plasma, is one of the basic tasks in clinical diagnostics. Bioanalytical assays used for the measuring should be able to measure proteins with high sensitivity and specificity. Furthermore, multiplexing capability would also be advantageous. To ensure the utility of the diagnostic test in point-of-care setting, additional requirements such as short turn-around times, ease-ofuse and low costs need to be met. On the other hand, enhancement of assay sensitivity could enable exploiting novel biomarkers, which are present in very low concentrations and which the current immunoassays are unable to measure. Furthermore, highly sensitive assays could enable the use of minimally invasive sampling. In the development of high-sensitivity assays the label technology and affinity binders are in pivotal role. Additionally, innovative assay designs contribute to the obtained sensitivity and other characteristics of the assay as well as its applicability. The aim of this thesis was to study the impact of assay components on the performance of both homogeneous and heterogeneous assays. Applicability of two different lanthanide-based label technologies, upconverting nanoparticles and switchable lanthanide luminescence, to protein detection was explored. Moreover, the potential of recombinant antibodies and aptamers as alternative affinity binders were evaluated. Additionally, alternative conjugation chemistries for production of the labeled binders were studied. Different assay concepts were also evaluated with respect to their applicability to point-of-care testing, which requires simple yet sensitive methods. The applicability of upconverting nanoparticles to the simultaneous quantitative measurement of multiple analytes using imaging-based detection was demonstrated. Additionally, the required instrumentation was relatively simple and inexpensive compared to other luminescent lanthanide-based labels requiring time-resolved measurement. The developed homogeneous assays exploiting switchable lanthanide luminescence were rapid and simple to perform and thus applicable even to point-ofcare testing. The sensitivities of the homogeneous assays were in the picomolar range, which are still inadequate for some analytes, such as cardiac troponins, requiring ultralow limits of detection. For most analytes, however, the obtained limits of detection were sufficient. The use of recombinant antibody fragments and aptamers as binders allowed site-specific and controlled covalent conjugation to construct labeled binders reproducibly either by using chemical modification or recombinant technology. Luminescent lanthanide labels were shown to be widely applicable for protein detection in various assay setups and to contribute assay sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pheochromocytomas are rare chromaffin cell tumors that nevertheless must be excluded in large numbers of patients who develop sustained or episodic hypertension as well as in many others with suggestive symptoms or with a familial history of pheochromocytoma. Diagnosis of pheochromocytoma depends importantly on biochemical evidence of excess catecholamine production by a tumor. Imperfect sensitivity and specificity of commonly available biochemical tests and the low incidence of the tumor among the tested population mean that considerable time and effort can be expended in confirming or ruling out pheochromocytoma in patients where the tumor is suspected. Measurements of plasma free metanephrines provide a superior test compared to other available tests for diagnosis of pheochromocytoma. In particular, the high sensitivity of plasma free metanephrines means that a normal test result reliably excludes all but the smallest of pheochromocytomas so that no other tests are necessary. Measurements of plasma free metanephrines, when systematically combined with other diagnostic procedures outlined in this review, provide a more efficient, reliable and cost-effective approach for diagnosis of pheochromocytoma than offered by previously available approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Salivary cortisol is an index of plasma free cortisol and is obtained by a noninvasive procedure. We have been using salivary cortisol as a tool for physiological and diagnostic studies, among them the emergence of circadian rhythm in preterm and term infants. The salivary cortisol circadian rhythm in term and premature infants was established between 8 and 12 postnatal weeks. In the preterm infants the emergence of circadian rhythm was parallel to the onset of sleep rhythm. We also studied the use of salivary cortisol for screening for Cushing's syndrome (CS) in control and obese outpatients based on circadian rhythm and the overnight 1 mg dexamethasone (DEX) suppression test. Salivary cortisol was suppressed to less than 100 ng/dl after 1 mg DEX in control and obese patients. A single salivary cortisol measurement at 23:00 h and again after 1 mg DEX above the 90th percentile of the obese group values had sensitivity and specificity of 93 and 93% (23:00 h), and 91 and 94% (after DEX), respectively. The sensitivity improved to 100% when we combined both parameters. We also studied 11 CS children and 21 age-matched primary obese children for whom salivary cortisol sensitivity and specificity were 100/95% (23:00 h), and 100/95% (1 mg DEX), respectively. Similar to adults, sensitivity and specificity of 100% were obtained by combining 23:00 h and 1 mg DEX. The measurement of salivary cortisol is a useful tool for physiological studies and for the diagnosis of CS in children and adults on an outpatient basis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To identify early metabolic abnormalities in type 2 diabetes mellitus, we measured insulin secretion, sensitivity to insulin, and hepatic insulin extraction in 48 healthy normal glucose-tolerant Brazilians, first-degree relatives of type 2 diabetic patients (FH+). Each individual was matched for sex, age, weight, and body fat distribution with a person without history of type 2 diabetes (FH-). Both groups were submitted to a hyperglycemic clamp procedure (180 mg/dl). Insulin release was evaluated in its two phases. The first was calculated as the sum of plasma insulin at 2.5, 5.0, 7.5, and 10.0 min after the beginning of glucose infusion, and the second as the mean plasma insulin level in the third hour of the clamp procedure. Insulin sensitivity index (ISI) was the mean glucose infusion rate in the third hour of the clamp experiment divided by the mean plasma insulin concentration during the same period of time. Hepatic insulin extraction was determined under fasting conditions and in the third hour of the clamp procedure as the ratio between C-peptide and plasma insulin levels. FH+ individuals did not differ from FH- individuals in terms of the following parameters [median (range)]: a) first-phase insulin secretion, 174 (116-221) vs 207 (108-277) µU/ml, b) second-phase insulin secretion, 64 (41-86) vs 53 (37-83) µU/ml, and c) ISI, 14.8 (9.0-20.8) vs 16.8 (9.0-27.0) mg kg-1 min-1/µU ml-1. Hepatic insulin extraction in FH+ subjects was similar to that of FH- ones at basal conditions (median, 0.27 vs 0.27 ng/µU) and during glucose infusion (0.15 vs 0.15 ng/µU). Normal glucose-tolerant Brazilian FH+ individuals well-matched with FH- ones did not show defects of insulin secretion, insulin sensitivity, or hepatic insulin extraction as tested by hyperglycemic clamp procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laminin levels in ascitic fluid have been proposed as a marker for neoplastic ascites. We compared the concentration of laminin in serum and in ascitic fluid from patients with hepatic cirrhosis and peritoneal carcinomatosis and assessed the diagnostic value of serum laminin levels in differentiating neoplastic from benign ascites. Laminin concentrations were determined by ELISA with antibodies against laminin extracted from the human placenta, in patients with ascites due to peritoneal carcinomatosis (N = 20) and hepatic cirrhosis (N = 33). Patients with infected or hemorrhagic ascites were excluded. The receiver operating characteristic curve was used to determine the sensitivity and specificity of serum laminin for the diagnosis of neoplastic ascites. When compared to the group with cirrhosis, the carcinomatosis group presented significantly higher mean laminin levels in serum (3.3 ± 0.5 vs 2.1 ± 0.4 µg/ml, mean ± SD, P < 0.05) and ascites (2.8 ± 0.5 vs 1.6 ± 0.4 µg/ml, P < 0.05). Although laminin concentration was higher in serum than in ascites, the laminin serum/ascites ratio and serum-ascites gradient did not differ between the studied groups. A significant correlation (r = 0.93, P < 0.0001) was observed between the serum and ascites laminin values. Serum laminin levels >2.25 µg/ml showed 100% sensitivity and 73% specificity for the diagnosis of neoplastic ascites. Serum concentration seems to be the main determinant of laminin levels in ascitic fluid and its values can be used as a diagnostic parameter in the study of neoplastic ascites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Escherichia coli K-12 (pEGFPluxABCDEAmp) (E. coli-lux), constitutively emitting bioluminescence (BL), was constructed and its BL emitting properties tested in different growth and killing conditions. The BL emission directly correlated with the number of viable E. coli-lux cells, and when subjected to the antimicrobial agent, the diminishment of the BL signal was linked directly to the number of killed bacterial cells. The method provided a very convenient application, especially when compared to conventional plate counting assays. This novel real-time based method was utilized in both immunological and toxicological assessments. The parameters such as the activation phase, the lytic phase and the capacity of the killing of the serum complement system were specified not only in humans but also in other species. E. coli-lux was also successfully used to study the antimicrobial activities of insect haemolymph. The mechanisms of neutrophil activity, like that of a myeloperoxidase (MPO)-H2O2-halide system, were studied using the E. coli-lux approach. The fundamental role of MPO was challenged, since during the actual killing in described circumstances in phagolysosome the MPO system was inactivated and chlorination halted. The toxicological test system, assessing indoor air total toxicity, particularly suitable for suspected mold damages, was designed based on the E. coli-lux method. Susceptibility to the vast number of various toxins, both pure chemicals and dust samples from the buildings and extracts from molds, were investigated. The E. coli-lux application was found to possess high sensitivity and specificity attributes. Alongside the analysis system, the sampling kit for indoor dust was engineered based on the swipe stick and the container. The combination of practical specimen collector and convenient analysis system provided accurate toxic data from the dust sample within hours. Neutrophils are good indicators of the pathophysiological state of the individual, and they can be utilized as a toxicological probe due to their ability to emit chemiluminescence (CL). Neutrophils can either be used as probe cells, directly exposed to the agent studied, or they can act as indicators of the whole biological system exposed to the agent. Human neutrophils were exposed to the same toxins as tested with the E. coli-lux system and measured as luminol amplified CL emission. The influence of the toxins on the individuals was investigated by exposing rats with moniliniformin, the mycotoxin commonly present in Finnish grains. The activity of the rat neutrophils was found to decrease significantly during the 28 days of exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.