998 resultados para Radiology, Medical.
Resumo:
A method is presented for the systematic design of asymmetric zonal shim coils for magnetic resonance applications. Fourier-series methods are used to represent the magnetic field inside and outside a circular cylinder of length 2L and radius a. The current density on the cylinder is also represented using Fourier series. Any desired field can be specified in advance on the cylinder's radius, over some nonsymmetric portion pL
Resumo:
In this work, a new method of optimization is successfully applied to the theoretical design of compact, actively shielded, clinical MRI magnets. The problem is formulated as a two-step process in which the desired current densities on multiple, cc-axial surface layers are first calculated by solving Fredholm equations of the first kind. Non-linear optimization methods with inequality constraints are then invoked to fit practical magnet coils to the desired current densities. The current density approach allows rapid prototyping of unusual magnet designs. The emphasis of this work is on the optimal design of short, actively-shielded MRI magnets for whole-body imaging. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric, and asymmetric MRI magnets. Magnet designs are presented for actively-shielded, symmetric magnets of coil length 1.0 m, which is considerably shorter than currently available designs of comparable dsv size. Novel, actively-shielded, asymmetric magnet designs are also presented in which the beginning of a 50-cm dsv is positioned just 11 cm from the end of the coil structure, allowing much improved access to the patient and reduced patient claustrophobia. Magn Reson Med 45:331540, 2001. (C) 2001 Wiley-Liss, Inc.
Resumo:
When patients undergo a magnetic resonance imaging scan, they are subject to both strong static and temporal magnetic fields. The temporal fields are designed to vary at each point in the region being imaged. This is achieved by the use of gradient coils. However, when the gradient coils are switched very rapidly, the strongly time-varying magnetic fields produced can be responsible for stimulating nerves in the peripheral regions of the body. This paper gives a somewhat novel explanation for this phenomenon. The physical mechanism suggested is supported by an illustrative theoretical calculation.
Resumo:
The present study investigates human visual processing of simple two-colour patterns using a delayed match to sample paradigm with positron emission tomography (PET). This study is unique in that we specifically designed the visual stimuli to be the same for both pattern and colour recognition with all patterns being abstract shapes not easily verbally coded composed of two-colour combinations. We did this to explore those brain regions required for both colour and pattern processing and to separate those areas of activation required for one or the other. We found that both tasks activated similar occipital regions, the major difference being more extensive activation in pattern recognition. A right-sided network that involved the inferior parietal lobule, the head of the caudate nucleus, and the pulvinar nucleus of the thalamus was common to both paradigms. Pattern recognition also activated the left temporal pole and right lateral orbital gyrus, whereas colour recognition activated the left fusiform gyrus and several right frontal regions. (C) 2001 Wiley-Liss, Inc.
Resumo:
Lateral ventricular volumes based on segmented brain MR images can be significantly underestimated if partial volume effects are not considered. This is because a group of voxels in the neighborhood of lateral ventricles is often mis-classified as gray matter voxels due to partial volume effects. This group of voxels is actually a mixture of ventricular cerebro-spinal fluid and the white matter and therefore, a portion of it should be included as part of the lateral ventricular structure. In this note, we describe an automated method for the measurement of lateral ventricular volumes on segmented brain MR images. Image segmentation was carried in combination of intensity correction and thresholding. The method is featured with a procedure for addressing mis-classified voxels in the surrounding of lateral ventricles. A detailed analysis showed that lateral ventricular volumes could be underestimated by 10 to 30% depending upon the size of the lateral ventricular structure, if mis-classified voxels were not included. Validation of the method was done through comparison with the averaged manually traced volumes. Finally, the merit of the method is demonstrated in the evaluation of the rate of lateral ventricular enlargement. (C) 2001 Elsevier Science Inc. All rights reserved.
Resumo:
Novel current density mapping (CDM) schemes are developed for the design of new actively shielded, clinical magnetic resonance imaging (MRI) magnets. This is an extended inverse method in which the entire potential solution space for the superconductors has been considered, rather than single current density layers. The solution provides an insight into the required superconducting coil pattern for a desired magnet configuration. This information is then used as an initial set of parameters for the magnet structure, and a previously developed hybrid numerical optimization technique is used to obtain the final geometry of the magnet. The CDM scheme is applied to the design of compact symmetric, asymmetric, and open architecture 1.0-1.5 T MRI magnet systems of novel geometry and utility. A new symmetric 1.0-T system that is just I m in length with a full 50-cm diameter of the active, or sensitive, volume (DSV) is detailed, as well as an asymmetric system in which a 50-cm DSV begins just 14 cm from the end of the coil structure. Finally a 1.0-T open magnet system with a full 50-cm DSV is presented. These new designs provide clinically useful homogeneous regions and have appropriately restricted stray fields but, in some of the designs, the DSV is much closer to the end of the magnet system than in conventional designs. These new designs have the potential to reduce patient claustrophobia and improve physician access to patients undergoing scans. (C) 2002 Wiley Periodicals, Inc.
Resumo:
Today's challenge to medical educators is to provide continuing education that supports excellence in clinical practice while finding new approaches to make learning more stimulating, motivating, and entertaining. At our hospital we are experimenting with innovative teaching techniques, incorporating games and debate, which encapsulate core concepts of the theory of adult learning: active participation by learners, application of knowledge, informal presentation, and feedback(1).
Resumo:
The Building Partnerships Program at the University of Queensland, Australia seeks to address the dual challenge of preparing doctors who are responsive to the community while providing a meaningful context for social sciences learning. Through partnerships with a diverse range of community agencies, the program offers students opportunities to gain non-clinical perspectives on health and illness through structured learning activities including: family visits; community agency visits and attachments; and interview training. Students learn first-hand about psychosocial influences on health and how people manage health problems on a day-to-day basis. They also gain insights into the work of community agencies and how they as future doctors might work in partnership with them to enhance patient care. We outline the main components of the program, identify challenges and successes from student and community agency perspectives, and consider areas that invite further development.
Resumo:
No previous studies regarding either structured, strictly controlled pet visitation programmes in paediatric hospital wards or hospital staff attitudes towards them have been conducted in Australia. Information regarding these is essential in order to minimize problems during implementation of such programmes. The aim of the study was to analyse hospital staff perceptions regarding the introduction of a pet visitation programme in an acute paediatric medical ward prior to and following implementation of the programme and to compare attitudes between the various professional groups. The study consisted of two cross-sectional surveys. A total of 224 anonymous questionnaires were distributed to administrators, doctors, nursing staff and therapists 6 weeks before and 195 were distributed 12 weeks after the introduction of a pet visitation programme. Responses were received from 115 respondents (before the programme introduction) and 45 respondents (after the programme introduction). Prior to the introduction of the dog visitation programme, there were high staff expectations that the programme would distract children from their illness, relax children and that it was a worthwhile project for the hospital to undertake. Following implementation of the programme these expectations were strongly endorsed, in addition to the perception that the ward was a happier place, the work environment was more interesting and that nurses accepted the dogs. After implementation staff were less concerned about the possibility of dog bites and dogs doing damage to equipment. Allied health staff and non-clinical staff were more positive about the programme with respect to ward climate and acceptance than were doctors and nurses. We conclude that well-planned dog visitation programmes result in positive anticipation among staff and high levels of satisfaction following programme impact.
Resumo:
The management of 12 women who presented with a second primary oesophageal cancer following radiotherapy for breast cancer was reviewed. It was concluded that nine cases fitted the classical description of a radiation-induced malignancy. Most cases were successfully managed with combined modality therapy in spite of their previous radiotherapy. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
Patients with chronic or complex medical or psychiatric conditions are treated by many practitioners, including general practitioners (GPs). Formal liaison between primary and specialist is often assumed to offer benefits to patients The aim of this study was to assess the efficacy of formal liaison of GPs with specialist service providers on patient health outcomes, by conducting a systematic review of the published literature in MEDLINE, EMBASE, PsychINFO, CINAHL and Cochrane Library databases using the following search terms family physicians': synonyms of 'patient care planning', 'patient discharge' and 'patient care team'; and synonyms of 'randomised controlled trials'. Seven studies were identified, involving 963 subjects and 899 controls. most health outcomes were unchanged, although some physical and functional health outcomes were improved by formal liaison between GPs and specialist services, particularly among chronic mental illness patients. Some health outcomes worsened during the intervention. Patient retention rates within treatment programmes improved with GP involvement, as did patient satisfaction. Doctor (GP and specialist) behaviour changed, with reports of more rational use of resources and diagnostic tests, improved clinical skills, more frequent use of appropriate treatment strategies, and more frequent clinical behaviours designed to detect disease complications Cost effectiveness could not be determined. In conclusion, formal liaison between GPs and specialist services leaves most physical health outcomes unchanged, but improves functional outcomes in chronically mentally ill patients. It may confer modest long-term health benefits through improvements in patient concordance with treatment programmes and more effective clinical practice.
Resumo:
In the picture-word interference task, naming responses are facilitated when a distractor word is orthographically and phonologically related to the depicted object as compared to an unrelated word. We used event-related functional magnetic resonance imaging (fMRI) to investigate the cerebral hemodynamic responses associated with this priming effect. Serial (or independent-stage) and interactive models of word production that explicitly account for picture-word interference effects assume that the locus of the effect is at the level of retrieving phonological codes, a role attributed recently to the left posterior superior temporal cortex (Wernicke's area). This assumption was tested by randomly presenting participants with trials from orthographically related and unrelated distractor conditions and acquiring image volumes coincident with the estimated peak hemodynamic response for each trial. Overt naming responses occurred in the absence of scanner noise, allowing reaction time data to be recorded. Analysis of this data confirmed the priming effect. Analysis of the fMRI data revealed blood oxygen level-dependent signal decreases in Wernicke's area and the right anterior temporal cortex, whereas signal increases were observed in the anterior cingulate, the right orbitomedial prefrontal, somatosensory, and inferior parietal cortices, and the occipital lobe. The results are interpreted as supporting the locus for the facilitation effect as assumed by both classes of theoretical model of word production. In addition, our results raise the possibilities that, counterintuitively, picture-word interference might be increased by the presentation of orthographically related distractors, due to competition introduced by activation of phonologically related word forms, and that this competition requires inhibitory processes to be resolved. The priming effect is therefore viewed as being sufficient to offset the increased interference. We conclude that information from functional imaging studies might be useful for constraining theoretical models of word production. (C) 2002 Elsevier Science (USA).
Resumo:
Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.