919 resultados para Network-on-chip
Resumo:
Microfluidic technology has been successfully applied to isolate very rare tumor-derived epithelial cells (circulating tumor cells, CTCs) from blood with relatively high yield and purity, opening up exciting prospects for early detection of cancer. However, a major limitation of state-of-the-art CTC-chips is their inability to characterize the behavior and function of captured CTCs, for example to obtain information on proliferative and invasive properties or, ultimately, tumor re-initiating potential. Although CTCs can be efficiently immunostained with markers reporting phenotype or fate (e.g. apoptosis, proliferation), it has not yet been possible to reliably grow captured CTCs over long periods of time and at single cell level. It is challenging to remove CTCs from a microchip after capture, therefore such analyses should ideally be performed directly on-chip. To address this challenge, we merged CTC capture with three-dimensional (3D) tumor cell culture on the same microfluidic platform. PC3 prostate cancer cells were isolated from spiked blood on a transparent PDMS CTC-chip, encapsulated on-chip in a biomimetic hydrogel matrix (QGel™) that was formed in situ, and their clonal 3D spheroid growth potential was assessed by microscopy over one week in culture. The possibility to clonally expand a subset of captured CTCs in a near-physiological in vitro model adds an important element to the expanding CTC-chip toolbox that ultimately should improve prediction of treatment responses and disease progression.
Resumo:
In a retrospective cohort study undertaken in 12 European countries, 249 female narcoleptic patients with cataplexy (n = 216) and without cataplexy (n = 33) completed a self-administrated questionnaire regarding pregnancy and childbirth. The cohort was divided further into patients whose symptoms of narcolepsy started before or during pregnancy (308 pregnancies) and those in whom the first symptoms of narcolepsy appeared after delivery (106 pregnancies). Patients with narcolepsy during pregnancy were older during their first pregnancy (P < 0.001) and had a higher body mass index (BMI) prior to pregnancy (P < 0.01). Weight gain during pregnancy was higher in narcoleptic patients with cataplexy (P < 0.01). More patients with narcolepsy-cataplexy during pregnancy had impaired glucose metabolism and anaemia. Three patients experienced cataplexy during delivery. The rate of caesarean sections was higher in the narcolepsy-cataplexy group compared to the narcolepsy group (P < 0.05). The mean birth weight and gestational age of neonates were within the normal range and did not differ across groups. Neonatal care was affected adversely by symptoms of narcolepsy in 60.1% of those with narcolepsy during pregnancy. This study reports more obstetric complications in patients with narcolepsy-cataplexy during pregnancy; however, these were not severe. This group also had a higher BMI and higher incidence of impaired glucose metabolism during pregnancy. Caesarian section was conducted more frequently in narcolepsy-cataplexy patients, despite cataplexy being a rare event during delivery. Furthermore, symptoms of narcolepsy may render care of the infant more difficult.
Resumo:
The proposed work aims to facilitate the development of a microfluidic platform for the production of advanced microcapsules containing active agents which can be the functional constituents of self-healing composites. The creation of such microcapsules is enabled by the unique flow characteristics within microchannels including precise control over shear and interfacial forces for droplet creation and manipulation as well as the ability to form a solid shell either chemically or via the addition of thermal or irradiative energy. Microchannel design and a study of the fluid dynamics and mechanisms for shell creation are undertaken in order to establish a fabrication approach capable of producing healing-agent-containing microcapsules. An in-depth study of the process parameters has been undertaken in order to elucidate the advantages of this production technique including precise control of size (i.e., monodispersity) and surface morphology of the microcapsules. This project also aims to aid the optimization of the mechanical properties as well as healing performance of self-healing composites by studying the effects of the advantageous properties of the as-produced microcapsules. Scale-up of the microfluidic fabrication using parallel devices on a single chip as well as on-chip microcapsule production and shape control will also be investigated. It will be demonstrated that microfluidic fabrication is a versatile approach for the efficient creation of functional microcapsules allowing for superior design of self-healing composites.
Resumo:
To evaluate primary care physicians' attitude towards implementation of rotavirus (RV) immunisation into the Swiss immunisation schedule, an eight-question internet-based questionnaire was sent to the 3799 subscribers of InfoVac, a nationwide web-based expert network on immunisation issues, which reaches >95% of paediatricians and smaller proportions of other primary care physicians. Five demographic variables were also inquired. Descriptive statistics and multivariate analyses for the main outcome "acceptance of routine RV immunisation" and other variables were performed. Diffusion of innovation theory was used for data assessment. Nine-hundred seventy-seven questionnaires were returned (26%). Fifty percent of participants were paediatricians. Routine RV immunisation was supported by 146 participants (15%; so called early adopters), dismissed by 620 (64%), leaving 211 (21%) undecided. However, when asked whether they would recommend RV vaccination to parents if it were officially recommended by the federal authorities and reimbursed, 467 (48.5%; so called early majority) agreed to recommend RV immunisation. Multivariate analysis revealed that physicians who would immunise their own child (OR: 5.1; 95% CI: 4.1-6.3), hospital-based physicians (OR: 1.6; 95% CI: 1.1-2.3) and physicians from the French (OR: 1.6; 95% CI: 1.2-2.3) and Italian speaking areas of Switzerland (OR: 2.5; 95% CI: 1.1-5.8) were more likely to support RV immunisation. Diffusion of innovation theory predicts a >80% implementation if approximately 50% of a given population support an innovation. Introduction of RV immunisation in Switzerland is likely to be successful, if (i) the federal authorities issue an official recommendation and (ii) costs are covered by basic health care insurance.
Resumo:
We report the fabrication and field emission properties of high-density nano-emitter arrays with on-chip electron extraction gate electrodes and up to 106 metallic nanotips that have an apex curvature radius of a few nanometers and a the tip density exceeding 108 cm−2. The gate electrode was fabricated on top of the nano-emitter arrays using a self-aligned polymer mask method. By applying a hot-press step for the polymer planarization, gate–nanotip alignment precision below 10 nm was achieved. Fabricated devices exhibited stable field electron emission with a current density of 0.1 A cm−2, indicating that these are promising for applications that require a miniature high-brightness electron source.
Resumo:
CMOS-sensors, or in general Active Pixel Sensors (APS), are rapidly replacing CCDs in the consumer camera market. Due to significant technological advances during the past years these devices start to compete with CCDs also for demanding scientific imaging applications, in particular in the astronomy community. CMOS detectors offer a series of inherent advantages compared to CCDs, due to the structure of their basic pixel cells, which each contains their own amplifier and readout electronics. The most prominent advantages for space object observations are the extremely fast and flexible readout capabilities, feasibility for electronic shuttering and precise epoch registration,and the potential to perform image processing operations on-chip and in real-time. Here, the major challenges and design drivers for ground-based and space-based optical observation strategies for objects in Earth orbit have been analyzed. CMOS detector characteristics were critically evaluated and compared with the established CCD technology, especially with respect to the above mentioned observations. Finally, we simulated several observation scenarios for ground- and space-based sensor by assuming different observation and sensor properties. We will introduce the analyzed end-to-end simulations of the ground- and spacebased strategies in order to investigate the orbit determination accuracy and its sensitivity which may result from different values for the frame-rate, pixel scale, astrometric and epoch registration accuracies. Two cases were simulated, a survey assuming a ground-based sensor to observe objects in LEO for surveillance applications, and a statistical survey with a space-based sensor orbiting in LEO observing small-size debris in LEO. The ground-based LEO survey uses a dynamical fence close to the Earth shadow a few hours after sunset. For the space-based scenario a sensor in a sun-synchronous LEO orbit, always pointing in the anti-sun direction to achieve optimum illumination conditions for small LEO debris was simulated.
Resumo:
High-resolution chemical depth profiling measurements of copper films are presented. The 10 μm thick copper test samples were electrodeposited on a Si-supported Cu seed under galvanostatic conditions in the presence of particular plating additives (SPS, Imep, PEI, and PAG) used in the semiconductor industry for the on-chip metallization of interconnects. To probe the trend of these plating additives toward inclusion into the deposit upon growth, quantitative elemental mass spectrometric measurements at trace level concentration were conducted by using a sensitive miniature laser ablation ionization mass spectrometer (LIMS), originally designed and developed for in situ space exploration. An ultrashort pulsed laser system (τ ∼ 190 fs, λ = 775 nm) was used for ablation and ionization of sample material. We show that with our LIMS system, quantitative chemical mass spectrometric analysis with an ablation rate at the subnanometer level per single laser shot can be conducted. The measurement capabilities of our instrument, including the high vertical depth resolution coupled with high detection sensitivity of ∼10 ppb, high dynamic range ≥10(8), measurement accuracy and precision, is of considerable interest in various fields of application, where investigations with high lateral and vertical resolution of the chemical composition of solid materials are required, these include, e.g., wafers from semiconductor industry or studies on space weathered samples in space research.
Resumo:
The formation of blood vessels is a complex tissue-specific process that plays a pivotal role during developmental processes, in wound healing, cancer progression, fibrosis and other pathologies. To study vasculogenesis and vascular remodeling in the context of the lung, we developed an in-vitro microvascular model that closely mimics the human lung microvasculature in terms of 3D architecture, accessibility, functionality and cell types. Human pericytes from the distal airway were isolated and characterized using flow cytometry. To assess their role in the generation of normal microvessels, lung pericytes were mixed in fibrin gel and seeded into well-defined microcompartments together with primary endothelial cells (HUVEC). Patent microvessels covering an area of 3.1 mm2 formed within 3-5 days and were stable for up to 14 days. Soluble signals from the lung pericytes were necessary to establish perfusability, and pericytes migrated towards endothelial microvessels. Cell-cell communication in the form of adherens and tight junctions, as well as secretion of basement membrane was confirmed using transmission electron microscopy and immunocytochemistry on chip. Direct co-culture of pericytes with endothelial cells decreased the microvascular permeability by one order of magnitude from 17.8∙10-6 cm/s to 2.0∙10-6 cm/s and led to vessels with significantly smaller and less variable diameter. Upon phenylephrine administration, vasoconstriction was observed in microvessels lined with pericytes but not in endothelial microvessels only. Perfusable microvessels were also generated with human lung microvascular endothelial cells and lung pericytes. Human lung pericytes were thus shown to have a prominent influence on microvascular morphology, permeability, vasoconstriction and long-term stability in an in-vitro microvascular system. This biomimetic platform opens new possibilities to test functions and interactions of patient-derived cells in a physiologically relevant microvascular setting.
Resumo:
Focus of this study is the analysis of a local hydrogeological system in the subhumid outer tropics in the western African country of Benin. The aim was to characterize, qualify and quantify the hydrogeological and hydrological properties of the approx. 30 km2 big study area and to develop a conceptual hydrogeological model. This model should provide the basis for further studies on a regional scale. The main goal was to obtain the process knowledge of the hydrogeological system and to determine the process and the quantity of the groundwater recharge in the working area. According to the objectives, a broad hydrogeological approach was chosen. In a spacious network on the local scale TDR probes, suction cups and groundwater observation bores were installed. Also in a multidisciplinary cooperation with hydrology, geography, soil science, biology, meteorology and plant nutrition sciences, instruments like discharge gauging stations, tensiometers, lysimeter, climate stations, runoff plots and erosion pins were installed in the test site for the investigation of the relevant parameters of the hydrological cycle.
Resumo:
Distributed parallel execution systems speed up applications by splitting tasks into processes whose execution is assigned to different receiving nodes in a high-bandwidth network. On the distributing side, a fundamental problem is grouping and scheduling such tasks such that each one involves sufñcient computational cost when compared to the task creation and communication costs and other such practical overheads. On the receiving side, an important issue is to have some assurance of the correctness and characteristics of the code received and also of the kind of load the particular task is going to pose, which can be specified by means of certificates. In this paper we present in a tutorial way a number of general solutions to these problems, and illustrate them through their implementation in the Ciao multi-paradigm language and program development environment. This system includes facilities for parallel and distributed execution, an assertion language for specifying complex programs properties (including safety and resource-related properties), and compile-time and run-time tools for performing automated parallelization and resource control, as well as certification of programs with resource consumption assurances and efñcient checking of such certificates.
Resumo:
Dynamic thermal management techniques require a collection of on-chip thermal sensors that imply a significant area and power overhead. Finding the optimum number of temperature monitors and their location on the chip surface to optimize accuracy is an NP-hard problem. In this work we improve the modeling of the problem by including area, power and networking constraints along with the consideration of three inaccuracy terms: spatial errors, sampling rate errors and monitor-inherent errors. The problem is solved by the simulated annealing algorithm. We apply the algorithm to a test case employing three different types of monitors to highlight the importance of the different metrics. Finally we present a case study of the Alpha 21364 processor under two different constraint scenarios.
Resumo:
In this work, the power management techniques implemented in a high-performance node for Wireless Sensor Networks (WSN) based on a RAM-based FPGA are presented. This new node custom architecture is intended for high-end WSN applications that include complex sensor management like video cameras, high compute demanding tasks such as image encoding or robust encryption, and/or higher data bandwidth needs. In the case of these complex processing tasks, yet maintaining low power design requirements, it can be shown that the combination of different techniques such as extensive HW algorithm mapping, smart management of power islands to selectively switch on and off components, smart and low-energy partial reconfiguration, an adequate set of save energy modes and wake up options, all combined, may yield energy results that may compete and improve energy usage of typical low power microcontrollers used in many WSN node architectures. Actually, results show that higher complexity tasks are in favor of HW based platforms, while the flexibility achieved by dynamic and partial reconfiguration techniques could be comparable to SW based solutions.